CardioMEMS Implantation Using Gadolinium-based Contrast Agent: A Case Report

A 57-year-old woman with New York Heart Association Class III heart failure requiring multiple hospitalisations over the previous year presented for CardioMEMS implantation. Because of the patient’s allergy history of anaphylaxis to iodine-based contrast agent she underwent the device implantation w...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Aniket S Rali, Lynne W Stevenson, Sandip K Zalawadiya
Formato: article
Lenguaje:EN
Publicado: Radcliffe Medical Media 2021
Materias:
Acceso en línea:https://doaj.org/article/701a7508e463414da4527170bbe65a9f
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:701a7508e463414da4527170bbe65a9f
record_format dspace
spelling oai:doaj.org-article:701a7508e463414da4527170bbe65a9f2021-12-04T16:04:14ZCardioMEMS Implantation Using Gadolinium-based Contrast Agent: A Case Report10.15420/cfr.2021.032057-75592057-7540https://doaj.org/article/701a7508e463414da4527170bbe65a9f2021-04-01T00:00:00Zhttps://www.cfrjournal.com/articleindex/cfr.2021.03https://doaj.org/toc/2057-7540https://doaj.org/toc/2057-7559A 57-year-old woman with New York Heart Association Class III heart failure requiring multiple hospitalisations over the previous year presented for CardioMEMS implantation. Because of the patient’s allergy history of anaphylaxis to iodine-based contrast agent she underwent the device implantation with gadolinium-based contrast agent (Magnevist), which was successful.Aniket S RaliLynne W StevensonSandip K ZalawadiyaRadcliffe Medical MediaarticleDiseases of the circulatory (Cardiovascular) systemRC666-701ENCardiac Failure Review , Vol 7, Iss , Pp - (2021)
institution DOAJ
collection DOAJ
language EN
topic Diseases of the circulatory (Cardiovascular) system
RC666-701
spellingShingle Diseases of the circulatory (Cardiovascular) system
RC666-701
Aniket S Rali
Lynne W Stevenson
Sandip K Zalawadiya
CardioMEMS Implantation Using Gadolinium-based Contrast Agent: A Case Report
description A 57-year-old woman with New York Heart Association Class III heart failure requiring multiple hospitalisations over the previous year presented for CardioMEMS implantation. Because of the patient’s allergy history of anaphylaxis to iodine-based contrast agent she underwent the device implantation with gadolinium-based contrast agent (Magnevist), which was successful.
format article
author Aniket S Rali
Lynne W Stevenson
Sandip K Zalawadiya
author_facet Aniket S Rali
Lynne W Stevenson
Sandip K Zalawadiya
author_sort Aniket S Rali
title CardioMEMS Implantation Using Gadolinium-based Contrast Agent: A Case Report
title_short CardioMEMS Implantation Using Gadolinium-based Contrast Agent: A Case Report
title_full CardioMEMS Implantation Using Gadolinium-based Contrast Agent: A Case Report
title_fullStr CardioMEMS Implantation Using Gadolinium-based Contrast Agent: A Case Report
title_full_unstemmed CardioMEMS Implantation Using Gadolinium-based Contrast Agent: A Case Report
title_sort cardiomems implantation using gadolinium-based contrast agent: a case report
publisher Radcliffe Medical Media
publishDate 2021
url https://doaj.org/article/701a7508e463414da4527170bbe65a9f
work_keys_str_mv AT aniketsrali cardiomemsimplantationusinggadoliniumbasedcontrastagentacasereport
AT lynnewstevenson cardiomemsimplantationusinggadoliniumbasedcontrastagentacasereport
AT sandipkzalawadiya cardiomemsimplantationusinggadoliniumbasedcontrastagentacasereport
_version_ 1718372680723333120