Oral health-related quality of life of patients using single or two-implant mandibular overdentures with immediate loading protocols: A randomized controlled trial

Aim: Single implant-retained mandibular overdentures (1IMO) is a viable alternative to 2 implant-retained overdentures (2IMO) in edentulous patients. However, literature lacks in the quality of life (QoL) of these patients when treated with immediate loading protocols. The purpose of this study was...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Pravinkumar G Patil, Liang Lin Seow
Formato: article
Lenguaje:EN
Publicado: Wolters Kluwer Medknow Publications 2021
Materias:
Acceso en línea:https://doaj.org/article/7074bc8c35124279aa5820e37b495175
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:7074bc8c35124279aa5820e37b495175
record_format dspace
spelling oai:doaj.org-article:7074bc8c35124279aa5820e37b4951752021-11-19T10:59:31ZOral health-related quality of life of patients using single or two-implant mandibular overdentures with immediate loading protocols: A randomized controlled trial0972-40521998-405710.4103/jips.jips_328_21https://doaj.org/article/7074bc8c35124279aa5820e37b4951752021-01-01T00:00:00Zhttp://www.j-ips.org/article.asp?issn=0972-4052;year=2021;volume=21;issue=4;spage=375;epage=382;aulast=Patilhttps://doaj.org/toc/0972-4052https://doaj.org/toc/1998-4057Aim: Single implant-retained mandibular overdentures (1IMO) is a viable alternative to 2 implant-retained overdentures (2IMO) in edentulous patients. However, literature lacks in the quality of life (QoL) of these patients when treated with immediate loading protocols. The purpose of this study was to compare oral health-related QoL (OHRQoL) of patients using 1IMO or 2 IMO with immediate loading protocols at 1 month and 1 year. Settings and Design: Randomized Controlled Trial. Materials and Methods: Fifty-two edentulous participants treated with mandibular overdentures using either single implant (n = 26) or two implants (n = 26) with immediate loading protocol by a single operator. The low-profile stud-attachments (LOCATOR; Zest Anchors) were attached to the implants and female attachments were picked up within 0–7 days of implant placement. The OHRQoL was recorded using Oral Health Impact Profile-14 (OHIP-14) questionnaire either in English or in the Malay language before treatment and 1 month and 1 year after treatment. Statistical Analysis Used: Kruskal Wallis test was used to find out significant difference amongst 3 timepoints and 7 OHIP-14 domains and Mann-Whitney-U test to compare 1IMO or 2IMO groups. Results: Compared to baseline OHIP-14 scores, participants had a statistically significant decrease in total OHIP-14 at 1 month and 1 year after-treatment time points in both 1IMO and 2IMO groups (P < 0.05). The difference between 1 month and 1 year after-treatment total and subscale scores were also found to be statistically significant (P < 0.05). The overall QoL improvement was comparatively higher in 2IMO group than 1IMO group. The OHIP-14 scores were statistically different within seven domains (P < 0.05). Overall total scores between 1IMO and 2IMO groups were also found to be statistically significant (P < 0.05) at baseline and insignificant (P > 0.05) at 1 month and 1 year. Conclusions: Mandibular single and 2IMO improve the QoL of elderly edentulous Malaysian participants at 1 month of immediate loading and 1 year of recall. 1IMO may provide comparable QoL with the elderly patients using 2 implants.Pravinkumar G PatilLiang Lin SeowWolters Kluwer Medknow Publicationsarticlemandibular overdenturepatient-reported outcomesquality of lifesingle implant overdentureDentistryRK1-715ENThe Journal of Indian Prosthodontic Society, Vol 21, Iss 4, Pp 375-382 (2021)
institution DOAJ
collection DOAJ
language EN
topic mandibular overdenture
patient-reported outcomes
quality of life
single implant overdenture
Dentistry
RK1-715
spellingShingle mandibular overdenture
patient-reported outcomes
quality of life
single implant overdenture
Dentistry
RK1-715
Pravinkumar G Patil
Liang Lin Seow
Oral health-related quality of life of patients using single or two-implant mandibular overdentures with immediate loading protocols: A randomized controlled trial
description Aim: Single implant-retained mandibular overdentures (1IMO) is a viable alternative to 2 implant-retained overdentures (2IMO) in edentulous patients. However, literature lacks in the quality of life (QoL) of these patients when treated with immediate loading protocols. The purpose of this study was to compare oral health-related QoL (OHRQoL) of patients using 1IMO or 2 IMO with immediate loading protocols at 1 month and 1 year. Settings and Design: Randomized Controlled Trial. Materials and Methods: Fifty-two edentulous participants treated with mandibular overdentures using either single implant (n = 26) or two implants (n = 26) with immediate loading protocol by a single operator. The low-profile stud-attachments (LOCATOR; Zest Anchors) were attached to the implants and female attachments were picked up within 0–7 days of implant placement. The OHRQoL was recorded using Oral Health Impact Profile-14 (OHIP-14) questionnaire either in English or in the Malay language before treatment and 1 month and 1 year after treatment. Statistical Analysis Used: Kruskal Wallis test was used to find out significant difference amongst 3 timepoints and 7 OHIP-14 domains and Mann-Whitney-U test to compare 1IMO or 2IMO groups. Results: Compared to baseline OHIP-14 scores, participants had a statistically significant decrease in total OHIP-14 at 1 month and 1 year after-treatment time points in both 1IMO and 2IMO groups (P < 0.05). The difference between 1 month and 1 year after-treatment total and subscale scores were also found to be statistically significant (P < 0.05). The overall QoL improvement was comparatively higher in 2IMO group than 1IMO group. The OHIP-14 scores were statistically different within seven domains (P < 0.05). Overall total scores between 1IMO and 2IMO groups were also found to be statistically significant (P < 0.05) at baseline and insignificant (P > 0.05) at 1 month and 1 year. Conclusions: Mandibular single and 2IMO improve the QoL of elderly edentulous Malaysian participants at 1 month of immediate loading and 1 year of recall. 1IMO may provide comparable QoL with the elderly patients using 2 implants.
format article
author Pravinkumar G Patil
Liang Lin Seow
author_facet Pravinkumar G Patil
Liang Lin Seow
author_sort Pravinkumar G Patil
title Oral health-related quality of life of patients using single or two-implant mandibular overdentures with immediate loading protocols: A randomized controlled trial
title_short Oral health-related quality of life of patients using single or two-implant mandibular overdentures with immediate loading protocols: A randomized controlled trial
title_full Oral health-related quality of life of patients using single or two-implant mandibular overdentures with immediate loading protocols: A randomized controlled trial
title_fullStr Oral health-related quality of life of patients using single or two-implant mandibular overdentures with immediate loading protocols: A randomized controlled trial
title_full_unstemmed Oral health-related quality of life of patients using single or two-implant mandibular overdentures with immediate loading protocols: A randomized controlled trial
title_sort oral health-related quality of life of patients using single or two-implant mandibular overdentures with immediate loading protocols: a randomized controlled trial
publisher Wolters Kluwer Medknow Publications
publishDate 2021
url https://doaj.org/article/7074bc8c35124279aa5820e37b495175
work_keys_str_mv AT pravinkumargpatil oralhealthrelatedqualityoflifeofpatientsusingsingleortwoimplantmandibularoverdentureswithimmediateloadingprotocolsarandomizedcontrolledtrial
AT lianglinseow oralhealthrelatedqualityoflifeofpatientsusingsingleortwoimplantmandibularoverdentureswithimmediateloadingprotocolsarandomizedcontrolledtrial
_version_ 1718420137530359808