Epi-aortic Doppler measurement of cardiac output in univentricular connection

Ad J J C Bogers1, Martin van den Burg1,2, Ronald Schepp2, Jan Klein21Department of Cardiothoracic Surgery; 2Department of Anesthesiology, Thoraxcentre, Erasmus University Medical Centre, Rotterdam, The NetherlandsBackground: In the initial postoperative period after a Fontan-type operation for a uni...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Ad J J C Bogers, Martin van den Burg, Ronald Schepp, Jan Klein
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2009
Materias:
Acceso en línea:https://doaj.org/article/7090699a08eb43438568acd3926149f3
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:7090699a08eb43438568acd3926149f3
record_format dspace
spelling oai:doaj.org-article:7090699a08eb43438568acd3926149f32021-12-02T02:48:52ZEpi-aortic Doppler measurement of cardiac output in univentricular connection1179-1470https://doaj.org/article/7090699a08eb43438568acd3926149f32009-02-01T00:00:00Zhttp://www.dovepress.com/epi-aortic-doppler-measurement-of-cardiac-output-in-univentricular-con-a2839https://doaj.org/toc/1179-1470Ad J J C Bogers1, Martin van den Burg1,2, Ronald Schepp2, Jan Klein21Department of Cardiothoracic Surgery; 2Department of Anesthesiology, Thoraxcentre, Erasmus University Medical Centre, Rotterdam, The NetherlandsBackground: In the initial postoperative period after a Fontan-type operation for a univentricular circulation, cardiac output information is important, but cannot be provided by conventional methods due to the surgical reconstruction of the heart. In this regard we investigated the feasibility of epi-aortic Doppler measurements in order to calculate cardiac output.Methods: Epi-aortic cardiac output measurement was compared with Fick measurements as the gold standard in eight patients with a univentricular circulation after a Fontan-type operation.Results: The mean diameter of the aorta by epi-aortic measurement was 18 mm (range 14 to 25), by angiography 17 mm (range 10 to 24), correlation coefficient 0.88 (p < 0.05). The mean cardiac output by epi-aortic measurement was 2.8 l.min−1 (range 1.2 to 6.3), by the Fick calculations 1.8 l.min−1 (range 0.8 to 5.0). The correlation coefficient for cardiac output data in aortic diameters up to 20 millimeter in diameter was 0.55 (p < 0.05).Conclusions: Epi-aortic Doppler measurement of cardiac output after Fontan type reconstructions could be applied in aortas up to 20 millimeter in diameter. A reasonable correlation with Fick calculations was found. This was supported by Bland–Altman plotting. The method is intrinsically invasive, but application and removal of the device were easy and no complications related to the system were observed. An important restriction is the often present abnormal anatomy, either congenitally or after surgery.Keywords: cardiac output, Fontan circulation, epi-aortic Doppler, extravascular Doppler Ad J J C BogersMartin van den BurgRonald ScheppJan KleinDove Medical PressarticleMedical technologyR855-855.5ENMedical Devices: Evidence and Research, Vol 2009, Iss default, Pp 27-29 (2009)
institution DOAJ
collection DOAJ
language EN
topic Medical technology
R855-855.5
spellingShingle Medical technology
R855-855.5
Ad J J C Bogers
Martin van den Burg
Ronald Schepp
Jan Klein
Epi-aortic Doppler measurement of cardiac output in univentricular connection
description Ad J J C Bogers1, Martin van den Burg1,2, Ronald Schepp2, Jan Klein21Department of Cardiothoracic Surgery; 2Department of Anesthesiology, Thoraxcentre, Erasmus University Medical Centre, Rotterdam, The NetherlandsBackground: In the initial postoperative period after a Fontan-type operation for a univentricular circulation, cardiac output information is important, but cannot be provided by conventional methods due to the surgical reconstruction of the heart. In this regard we investigated the feasibility of epi-aortic Doppler measurements in order to calculate cardiac output.Methods: Epi-aortic cardiac output measurement was compared with Fick measurements as the gold standard in eight patients with a univentricular circulation after a Fontan-type operation.Results: The mean diameter of the aorta by epi-aortic measurement was 18 mm (range 14 to 25), by angiography 17 mm (range 10 to 24), correlation coefficient 0.88 (p < 0.05). The mean cardiac output by epi-aortic measurement was 2.8 l.min−1 (range 1.2 to 6.3), by the Fick calculations 1.8 l.min−1 (range 0.8 to 5.0). The correlation coefficient for cardiac output data in aortic diameters up to 20 millimeter in diameter was 0.55 (p < 0.05).Conclusions: Epi-aortic Doppler measurement of cardiac output after Fontan type reconstructions could be applied in aortas up to 20 millimeter in diameter. A reasonable correlation with Fick calculations was found. This was supported by Bland–Altman plotting. The method is intrinsically invasive, but application and removal of the device were easy and no complications related to the system were observed. An important restriction is the often present abnormal anatomy, either congenitally or after surgery.Keywords: cardiac output, Fontan circulation, epi-aortic Doppler, extravascular Doppler
format article
author Ad J J C Bogers
Martin van den Burg
Ronald Schepp
Jan Klein
author_facet Ad J J C Bogers
Martin van den Burg
Ronald Schepp
Jan Klein
author_sort Ad J J C Bogers
title Epi-aortic Doppler measurement of cardiac output in univentricular connection
title_short Epi-aortic Doppler measurement of cardiac output in univentricular connection
title_full Epi-aortic Doppler measurement of cardiac output in univentricular connection
title_fullStr Epi-aortic Doppler measurement of cardiac output in univentricular connection
title_full_unstemmed Epi-aortic Doppler measurement of cardiac output in univentricular connection
title_sort epi-aortic doppler measurement of cardiac output in univentricular connection
publisher Dove Medical Press
publishDate 2009
url https://doaj.org/article/7090699a08eb43438568acd3926149f3
work_keys_str_mv AT adjjcbogers epiaorticdopplermeasurementofcardiacoutputinuniventricularconnection
AT martinvandenburg epiaorticdopplermeasurementofcardiacoutputinuniventricularconnection
AT ronaldschepp epiaorticdopplermeasurementofcardiacoutputinuniventricularconnection
AT janklein epiaorticdopplermeasurementofcardiacoutputinuniventricularconnection
_version_ 1718402105656475648