Efficacy of the new β-D-glucan measurement kit for diagnosing invasive fungal infections, as compared with that of four conventional kits.
<h4>Background</h4>Each of the currently available (1→3)-β-D-glucan (BDG) measurement kits follows a different measurement method and cut-off value. Comparisons of diagnostic performance for invasive fungal infections (IFIs) are desirable. Additionally, ecological considerations are beco...
Guardado en:
Autores principales: | , , , , , , , , , , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Public Library of Science (PLoS)
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/70e651877f644db78bd88a7849765f8a |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:70e651877f644db78bd88a7849765f8a |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:70e651877f644db78bd88a7849765f8a2021-12-02T20:14:54ZEfficacy of the new β-D-glucan measurement kit for diagnosing invasive fungal infections, as compared with that of four conventional kits.1932-620310.1371/journal.pone.0255172https://doaj.org/article/70e651877f644db78bd88a7849765f8a2021-01-01T00:00:00Zhttps://doi.org/10.1371/journal.pone.0255172https://doaj.org/toc/1932-6203<h4>Background</h4>Each of the currently available (1→3)-β-D-glucan (BDG) measurement kits follows a different measurement method and cut-off value. Comparisons of diagnostic performance for invasive fungal infections (IFIs) are desirable. Additionally, ecological considerations are becoming increasingly important in the development of new measurement kits.<h4>Methods</h4>The plasma BDG levels in clinical samples were measured using the following currently available kits: the Fungitec G test MKII, the Fungitec G test ES, Fungitell, the β-Glucan test Wako, and the newly developed Wako kit (Wako-Eu). Wako-Eu uses a pre-treatment solution that conforms to European regulations for the registration, evaluation, authorisation, and restriction of chemicals. The values obtained for the samples using each kit were studied and compared.<h4>Results</h4>Of the 165 patients evaluated, 12 had IFIs, including pneumocystis pneumonia, aspergillosis, and candidiasis. BDG values obtained using the kits were moderately correlated with each other. Clinical diagnoses of the evaluated cases indicated that 21 false positives were diagnosed by at least one kit. The sensitivity of the Fungitell kit was relatively low, but those of the other four were over 90%. The specificity was above 90% for all kits. For positive predictive value, the Wako and the Wako-Eu methods were superior to the others owing to fewer false positive results.<h4>Conclusions</h4>The newly developed Wako-Eu method, which considers ecological concerns, shows diagnostic performance equivalent to that of its predecessor. To improve the diagnostic accuracy of IFIs, it is necessary to interpret the results carefully, giving due consideration to the characteristics of each measurement kit.Yuuki BambaKei NaganoHiroshi MoroHideyuki OgataMariko HakamataSatoshi ShibataTakeshi KoizumiNobumasa AokiYasuyoshi OhshimaSatoshi WatanabeTakeshi NakamuraSugako KobayashiYoshiki HoshiyamaToshiyuki KoyaToshinori TakadaToshiaki KikuchiPublic Library of Science (PLoS)articleMedicineRScienceQENPLoS ONE, Vol 16, Iss 8, p e0255172 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Yuuki Bamba Kei Nagano Hiroshi Moro Hideyuki Ogata Mariko Hakamata Satoshi Shibata Takeshi Koizumi Nobumasa Aoki Yasuyoshi Ohshima Satoshi Watanabe Takeshi Nakamura Sugako Kobayashi Yoshiki Hoshiyama Toshiyuki Koya Toshinori Takada Toshiaki Kikuchi Efficacy of the new β-D-glucan measurement kit for diagnosing invasive fungal infections, as compared with that of four conventional kits. |
description |
<h4>Background</h4>Each of the currently available (1→3)-β-D-glucan (BDG) measurement kits follows a different measurement method and cut-off value. Comparisons of diagnostic performance for invasive fungal infections (IFIs) are desirable. Additionally, ecological considerations are becoming increasingly important in the development of new measurement kits.<h4>Methods</h4>The plasma BDG levels in clinical samples were measured using the following currently available kits: the Fungitec G test MKII, the Fungitec G test ES, Fungitell, the β-Glucan test Wako, and the newly developed Wako kit (Wako-Eu). Wako-Eu uses a pre-treatment solution that conforms to European regulations for the registration, evaluation, authorisation, and restriction of chemicals. The values obtained for the samples using each kit were studied and compared.<h4>Results</h4>Of the 165 patients evaluated, 12 had IFIs, including pneumocystis pneumonia, aspergillosis, and candidiasis. BDG values obtained using the kits were moderately correlated with each other. Clinical diagnoses of the evaluated cases indicated that 21 false positives were diagnosed by at least one kit. The sensitivity of the Fungitell kit was relatively low, but those of the other four were over 90%. The specificity was above 90% for all kits. For positive predictive value, the Wako and the Wako-Eu methods were superior to the others owing to fewer false positive results.<h4>Conclusions</h4>The newly developed Wako-Eu method, which considers ecological concerns, shows diagnostic performance equivalent to that of its predecessor. To improve the diagnostic accuracy of IFIs, it is necessary to interpret the results carefully, giving due consideration to the characteristics of each measurement kit. |
format |
article |
author |
Yuuki Bamba Kei Nagano Hiroshi Moro Hideyuki Ogata Mariko Hakamata Satoshi Shibata Takeshi Koizumi Nobumasa Aoki Yasuyoshi Ohshima Satoshi Watanabe Takeshi Nakamura Sugako Kobayashi Yoshiki Hoshiyama Toshiyuki Koya Toshinori Takada Toshiaki Kikuchi |
author_facet |
Yuuki Bamba Kei Nagano Hiroshi Moro Hideyuki Ogata Mariko Hakamata Satoshi Shibata Takeshi Koizumi Nobumasa Aoki Yasuyoshi Ohshima Satoshi Watanabe Takeshi Nakamura Sugako Kobayashi Yoshiki Hoshiyama Toshiyuki Koya Toshinori Takada Toshiaki Kikuchi |
author_sort |
Yuuki Bamba |
title |
Efficacy of the new β-D-glucan measurement kit for diagnosing invasive fungal infections, as compared with that of four conventional kits. |
title_short |
Efficacy of the new β-D-glucan measurement kit for diagnosing invasive fungal infections, as compared with that of four conventional kits. |
title_full |
Efficacy of the new β-D-glucan measurement kit for diagnosing invasive fungal infections, as compared with that of four conventional kits. |
title_fullStr |
Efficacy of the new β-D-glucan measurement kit for diagnosing invasive fungal infections, as compared with that of four conventional kits. |
title_full_unstemmed |
Efficacy of the new β-D-glucan measurement kit for diagnosing invasive fungal infections, as compared with that of four conventional kits. |
title_sort |
efficacy of the new β-d-glucan measurement kit for diagnosing invasive fungal infections, as compared with that of four conventional kits. |
publisher |
Public Library of Science (PLoS) |
publishDate |
2021 |
url |
https://doaj.org/article/70e651877f644db78bd88a7849765f8a |
work_keys_str_mv |
AT yuukibamba efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT keinagano efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT hiroshimoro efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT hideyukiogata efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT marikohakamata efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT satoshishibata efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT takeshikoizumi efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT nobumasaaoki efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT yasuyoshiohshima efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT satoshiwatanabe efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT takeshinakamura efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT sugakokobayashi efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT yoshikihoshiyama efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT toshiyukikoya efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT toshinoritakada efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT toshiakikikuchi efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits |
_version_ |
1718374651726397440 |