A rapid and highly sensitive protocol for the detection of Escherichia coli O157:H7 based on immunochromatography assay combined with the enrichment technique of immunomagnetic nanoparticles

Hui Qi1, Zhen Zhong1, Han-Xin Zhou1, Chun-Yan Deng1, Hai Zhu2, Jin-Feng Li2, Xi-Li Wang2, Fu-Rong Li1,31Clinical Medical Research Center, The Second Clinical Medical College (Shenzhen People's Hospital), Jinan University, 2Shenzhen Bioeasy Biotechnologies Co, Ltd, 3Shenzhen Institute of...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Qi H, Zhong Z, Zhou HX, Deng CY, Zhu H, Li JF, Wang XL, Li FR
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2011
Materias:
Acceso en línea:https://doaj.org/article/721360c1eb03481da86b638fe6feb9d5
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:Hui Qi1, Zhen Zhong1, Han-Xin Zhou1, Chun-Yan Deng1, Hai Zhu2, Jin-Feng Li2, Xi-Li Wang2, Fu-Rong Li1,31Clinical Medical Research Center, The Second Clinical Medical College (Shenzhen People's Hospital), Jinan University, 2Shenzhen Bioeasy Biotechnologies Co, Ltd, 3Shenzhen Institute of Gerontology, Shenzhen, People's Republic of ChinaBackground: Escherichia coli O157:H7 (E. coli O157:H7) is an important pathogenic bacterium that threatens human health. A rapid, simple, highly sensitive, and specific method for the detection of E. coli O157:H7 is necessary.Methods: In the present study, immunomagnetic nanoparticles (IMPs) were prepared with nanopure iron as the core, coated with E. coli O157:H7 polyclonal antibodies. These IMPs were used in combination with immunochromatographic assay (ICA) and used to establish highly sensitive and rapid kits (IMPs+ICA) to detect E. coli O157:H7. The kits were then used to detect E. coli O157:H7 in 150 food samples and were compared with conventional ICA to evaluate their efficacy.Results: The average diameter of IMPs was 56 nm and the amount of adsorbed antibodies was 106.0 µg/mg. The sensitivity of ICA and IMPs+ICA was 105 colony-forming units/mL and 103 CFUs/mL, respectively, for purified E. coli O157:H7 solution. The sensitivity of IMPs+ICA was increased by two orders, and its specificity was similar to ICA.Conclusion: The kits have the potential to offer important social and economic benefits in the screening, monitoring, and control of food safety.Keywords: colloidal gold, immunomagnetic nanoparticles, Escherichia coli O157:H7, immunochromatographic assay