A novel electrocardiographic index for the diagnosis of diastolic dysfunction.

<h4>Background</h4>Although the assessment of diastolic dysfunction (DD) is an integral part of routine cardiologic examinations, little is known about associated electrocardiographic (ECG) changes. Our aim was to investigate a potential role of ECG indices for the recognition of patient...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Mehdi Namdar, Patric Biaggi, Barbara Stähli, Bernhard Bütler, Rubén Casado-Arroyo, Danilo Ricciardi, Moisés Rodríguez-Mañero, Jan Steffel, David Hürlimann, Christian Schmied, Carlo de Asmundis, Gian-Battista Chierchia, Andrea Sarkozy, Thomas F Lüscher, Rolf Jenni, Firat Duru, Walter J Paulus, Pedro Brugada
Formato: article
Lenguaje:EN
Publicado: Public Library of Science (PLoS) 2013
Materias:
R
Q
Acceso en línea:https://doaj.org/article/727165ec93f445be86d570884cd4056f
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:<h4>Background</h4>Although the assessment of diastolic dysfunction (DD) is an integral part of routine cardiologic examinations, little is known about associated electrocardiographic (ECG) changes. Our aim was to investigate a potential role of ECG indices for the recognition of patients with DD.<h4>Methods and results</h4>ECG parameters correlating with echocardiographic findings of DD were retrospectively assessed in a derivation group of 172 individuals (83 controls with normal diastolic function, 89 patients with DD) and their diagnostic performance was tested in a validation group of 50 controls and 50 patients. The patient group with a DD Grade 1 and 2 showed longer QTc (422 ± 24 ms and 434 ± 32 ms vs. 409 ± 25ms, p<0.0005) and shorter Tend-P and Tend-Q intervals, reflecting the electrical and mechanical diastole (240 ± 78 ms and 276 ± 108 ms vs. 373 ± 110 ms, p<0.0001; 409 ± 85 ms and 447 ± 115 ms vs. 526 ± 119 ms, p<0.0001). The PQ-interval was significantly longer in the patient group (169 ± 28ms and 171 ± 38ms vs. 153 ± 22ms, p<0.005). After adjusting for possible confounders, a novel index (Tend-P/[PQxAge]) showed a high performance for the recognition of DD, stayed robust in the validation group (sensitivity 82%, specificity 93%, positive predictive value 93%, negative predictive value 82%, accuracy 88%) and proved a substantial added value when combined with the indexed left atrial volume (LAESVI, sensitivity 90%, specificity 92%, positive predictive value 95%, negative predictive value 86%, accuracy 91%).<h4>Conclusions</h4>A novel electrocardiographic index Tend-P/(PQxAge) demonstrates a high diagnostic accuracy for the diagnosis of DD and yields a substantial added value when combined with the LAESVI.