GENERAL QUESTIONS AS TO PROVIDING ELECTROMAGNETIC COMPATIBILITY OF POWER CABLE LINES, THEIR AMPERAGE CAPACITY AND TYPES OF SHIELD CONSTRUCTION

Works studying ways of reducing magnetic fields of cross-linked polyethylene power cable lines are reviewed. Different aspects of single-phase power cable shield construction influence on thermal conditions of a three-phase power cable line are analyzed. Questions concerning electromagnetic compatib...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autor principal: I.A. Kostiukov
Formato: article
Lenguaje:EN
RU
UK
Publicado: National Technical University "Kharkiv Polytechnic Institute" 2013
Materias:
Acceso en línea:https://doaj.org/article/72bccfb265b1449a8ffa6e88e5e641f4
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:72bccfb265b1449a8ffa6e88e5e641f4
record_format dspace
spelling oai:doaj.org-article:72bccfb265b1449a8ffa6e88e5e641f42021-12-02T15:27:29ZGENERAL QUESTIONS AS TO PROVIDING ELECTROMAGNETIC COMPATIBILITY OF POWER CABLE LINES, THEIR AMPERAGE CAPACITY AND TYPES OF SHIELD CONSTRUCTION2074-272Xhttps://doaj.org/article/72bccfb265b1449a8ffa6e88e5e641f42013-09-01T00:00:00Zhttp://eie.khpi.edu.ua/article/view/16934/14607https://doaj.org/toc/2074-272XWorks studying ways of reducing magnetic fields of cross-linked polyethylene power cable lines are reviewed. Different aspects of single-phase power cable shield construction influence on thermal conditions of a three-phase power cable line are analyzed. Questions concerning electromagnetic compatibility of power cables are considered.I.A. KostiukovNational Technical University "Kharkiv Polytechnic Institute"articleeddy current losscirculating currentelectromagnetic compatibilityElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENRUUKElectrical engineering & Electromechanics, Iss 4, Pp 65-68 (2013)
institution DOAJ
collection DOAJ
language EN
RU
UK
topic eddy current loss
circulating current
electromagnetic compatibility
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
spellingShingle eddy current loss
circulating current
electromagnetic compatibility
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
I.A. Kostiukov
GENERAL QUESTIONS AS TO PROVIDING ELECTROMAGNETIC COMPATIBILITY OF POWER CABLE LINES, THEIR AMPERAGE CAPACITY AND TYPES OF SHIELD CONSTRUCTION
description Works studying ways of reducing magnetic fields of cross-linked polyethylene power cable lines are reviewed. Different aspects of single-phase power cable shield construction influence on thermal conditions of a three-phase power cable line are analyzed. Questions concerning electromagnetic compatibility of power cables are considered.
format article
author I.A. Kostiukov
author_facet I.A. Kostiukov
author_sort I.A. Kostiukov
title GENERAL QUESTIONS AS TO PROVIDING ELECTROMAGNETIC COMPATIBILITY OF POWER CABLE LINES, THEIR AMPERAGE CAPACITY AND TYPES OF SHIELD CONSTRUCTION
title_short GENERAL QUESTIONS AS TO PROVIDING ELECTROMAGNETIC COMPATIBILITY OF POWER CABLE LINES, THEIR AMPERAGE CAPACITY AND TYPES OF SHIELD CONSTRUCTION
title_full GENERAL QUESTIONS AS TO PROVIDING ELECTROMAGNETIC COMPATIBILITY OF POWER CABLE LINES, THEIR AMPERAGE CAPACITY AND TYPES OF SHIELD CONSTRUCTION
title_fullStr GENERAL QUESTIONS AS TO PROVIDING ELECTROMAGNETIC COMPATIBILITY OF POWER CABLE LINES, THEIR AMPERAGE CAPACITY AND TYPES OF SHIELD CONSTRUCTION
title_full_unstemmed GENERAL QUESTIONS AS TO PROVIDING ELECTROMAGNETIC COMPATIBILITY OF POWER CABLE LINES, THEIR AMPERAGE CAPACITY AND TYPES OF SHIELD CONSTRUCTION
title_sort general questions as to providing electromagnetic compatibility of power cable lines, their amperage capacity and types of shield construction
publisher National Technical University "Kharkiv Polytechnic Institute"
publishDate 2013
url https://doaj.org/article/72bccfb265b1449a8ffa6e88e5e641f4
work_keys_str_mv AT iakostiukov generalquestionsastoprovidingelectromagneticcompatibilityofpowercablelinestheiramperagecapacityandtypesofshieldconstruction
_version_ 1718387209534439424