Position evaluation of ex-core neutron flux measurement in new type graphite reactors

Several concepts of new reactors use graphite. Some of them use graphite as a moderator, some of them as a reflector. There are at least two concepts of these graphitetype reactors under development in the Czech Republic. Both reactors use graphite as the reflector. An in-core measurement might be i...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Vilimova Eva, Peltan Tomas, Skoda Radek
Formato: article
Lenguaje:EN
Publicado: EDP Sciences 2021
Materias:
Acceso en línea:https://doaj.org/article/731cb433b7bf44f09109fb2c01dfbb56
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:731cb433b7bf44f09109fb2c01dfbb56
record_format dspace
spelling oai:doaj.org-article:731cb433b7bf44f09109fb2c01dfbb562021-12-02T17:12:46ZPosition evaluation of ex-core neutron flux measurement in new type graphite reactors2100-014X10.1051/epjconf/202125305005https://doaj.org/article/731cb433b7bf44f09109fb2c01dfbb562021-01-01T00:00:00Zhttps://www.epj-conferences.org/articles/epjconf/pdf/2021/07/epjconf_animma2021_05005.pdfhttps://doaj.org/toc/2100-014XSeveral concepts of new reactors use graphite. Some of them use graphite as a moderator, some of them as a reflector. There are at least two concepts of these graphitetype reactors under development in the Czech Republic. Both reactors use graphite as the reflector. An in-core measurement might be impossible to use because of various reasons, for instance, high temperature or aggressive environment. Therefore, this article focuses on ex-core neutron flux measurement system placed in the graphite reflector and the optimization of ex-core detector position. A set of experiments were performed at LR-0 reactor. The LR-0 is a light water reactor with a well-defined neutron field, which can be used for different material insertion tests and testing of its influence on criticality. Several modifications of LR-0 cores were modelled in Monte Carlo codes Serpent and KENO. A set of calculations were performed for verification of the criticality and neutron flux course in the reactor core and graphite reflector. Further investigation was focused on the influence of the presence of a graphite reflector on the neutron distribution in the reactor core. The LR-0 graphite experiments were also used to verify the calculations. Based on the results of this article, the optimal position of ex-core detectors in the graphite reflector is proposed.Vilimova EvaPeltan TomasSkoda RadekEDP Sciencesarticleex-core measurementneutron fluxgraphite reflectorserpentkenoPhysicsQC1-999ENEPJ Web of Conferences, Vol 253, p 05005 (2021)
institution DOAJ
collection DOAJ
language EN
topic ex-core measurement
neutron flux
graphite reflector
serpent
keno
Physics
QC1-999
spellingShingle ex-core measurement
neutron flux
graphite reflector
serpent
keno
Physics
QC1-999
Vilimova Eva
Peltan Tomas
Skoda Radek
Position evaluation of ex-core neutron flux measurement in new type graphite reactors
description Several concepts of new reactors use graphite. Some of them use graphite as a moderator, some of them as a reflector. There are at least two concepts of these graphitetype reactors under development in the Czech Republic. Both reactors use graphite as the reflector. An in-core measurement might be impossible to use because of various reasons, for instance, high temperature or aggressive environment. Therefore, this article focuses on ex-core neutron flux measurement system placed in the graphite reflector and the optimization of ex-core detector position. A set of experiments were performed at LR-0 reactor. The LR-0 is a light water reactor with a well-defined neutron field, which can be used for different material insertion tests and testing of its influence on criticality. Several modifications of LR-0 cores were modelled in Monte Carlo codes Serpent and KENO. A set of calculations were performed for verification of the criticality and neutron flux course in the reactor core and graphite reflector. Further investigation was focused on the influence of the presence of a graphite reflector on the neutron distribution in the reactor core. The LR-0 graphite experiments were also used to verify the calculations. Based on the results of this article, the optimal position of ex-core detectors in the graphite reflector is proposed.
format article
author Vilimova Eva
Peltan Tomas
Skoda Radek
author_facet Vilimova Eva
Peltan Tomas
Skoda Radek
author_sort Vilimova Eva
title Position evaluation of ex-core neutron flux measurement in new type graphite reactors
title_short Position evaluation of ex-core neutron flux measurement in new type graphite reactors
title_full Position evaluation of ex-core neutron flux measurement in new type graphite reactors
title_fullStr Position evaluation of ex-core neutron flux measurement in new type graphite reactors
title_full_unstemmed Position evaluation of ex-core neutron flux measurement in new type graphite reactors
title_sort position evaluation of ex-core neutron flux measurement in new type graphite reactors
publisher EDP Sciences
publishDate 2021
url https://doaj.org/article/731cb433b7bf44f09109fb2c01dfbb56
work_keys_str_mv AT vilimovaeva positionevaluationofexcoreneutronfluxmeasurementinnewtypegraphitereactors
AT peltantomas positionevaluationofexcoreneutronfluxmeasurementinnewtypegraphitereactors
AT skodaradek positionevaluationofexcoreneutronfluxmeasurementinnewtypegraphitereactors
_version_ 1718381385382625280