Defining radio-recurrent intra-prostatic target volumes using PSMA-targeted PET/CT and multi-parametric MRI

Purpose: Our purpose was to evaluate intra-prostatic cancer volumes for salvage radiotherapy in men with recurrent prostate cancer confined to the prostate post-primary radiotherapy using mpMRI and 18F-DCFPyL PET/CT (PET). Methods: Men with biochemical failure post-primary radiotherapy were enrolled...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Wei Liu, Hatim Fakir, Gurpreet Randhawa, Ryan Alfano, Mark Corkum, Zahra Kassam, Irina Rachinsky, Hans T. Chung, Peter Chung, Andrew Loblaw, Gerard Morton, Tracy Sexton, Anil Kapoor, Aaron Ward, Katherine Zukotynski, Louise Emmett, Glenn Bauman
Formato: article
Lenguaje:EN
Publicado: Elsevier 2022
Materias:
MRI
Acceso en línea:https://doaj.org/article/73250c64d9e24ee19ae41b44d5798e3d
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:73250c64d9e24ee19ae41b44d5798e3d
record_format dspace
spelling oai:doaj.org-article:73250c64d9e24ee19ae41b44d5798e3d2021-11-20T05:07:50ZDefining radio-recurrent intra-prostatic target volumes using PSMA-targeted PET/CT and multi-parametric MRI2405-630810.1016/j.ctro.2021.11.006https://doaj.org/article/73250c64d9e24ee19ae41b44d5798e3d2022-01-01T00:00:00Zhttp://www.sciencedirect.com/science/article/pii/S2405630821000975https://doaj.org/toc/2405-6308Purpose: Our purpose was to evaluate intra-prostatic cancer volumes for salvage radiotherapy in men with recurrent prostate cancer confined to the prostate post-primary radiotherapy using mpMRI and 18F-DCFPyL PET/CT (PET). Methods: Men with biochemical failure post-primary radiotherapy were enrolled in a multi-centre trial investigating mpMRI and PET. All men with isolated intra-prostatic recurrence are included in this secondary analysis. The intra-prostatic gross tumour volume (GTV) was manually delineated on mpMRI and was also delineated on PET using three methods: 1. manually, 2. using a 30% threshold of maximum intra-prostatic standard uptake value (SUVmax), and 3. using a 67% threshold of this SUVmax. Clinical target volumes (CTV) including expansions on each GTV were generated. Conformity indices were performed between the mpMRI CTV and each PET CTV. Correlation with biopsy and clinical outcomes were performed. Results: Of the 36 men included, 30 (83%) had disease in two quadrants or less using the combination of mpMRI and PET. Mean target volume (union of CTV on mpMRI and CTV manually delineated on PET) was 12.2 cc (49% of prostate gland volume). 12/36 (33%) men had a biopsy. Per-patient sensitivity was 91% for mpMRI and 82% for PET. Conclusions: mpMRI and PET provide complementary information for delineation of intra-prostatic recurrent disease. Union of CTV on mpMRI and PET is often less than 50% of the prostate, suggesting this imaging could help define a target for focal salvage therapy.Wei LiuHatim FakirGurpreet RandhawaRyan AlfanoMark CorkumZahra KassamIrina RachinskyHans T. ChungPeter ChungAndrew LoblawGerard MortonTracy SextonAnil KapoorAaron WardKatherine ZukotynskiLouise EmmettGlenn BaumanElsevierarticleProstate cancerPSMA PET/CTMRIRadio-recurrenceMedical physics. Medical radiology. Nuclear medicineR895-920Neoplasms. Tumors. Oncology. Including cancer and carcinogensRC254-282ENClinical and Translational Radiation Oncology, Vol 32, Iss , Pp 41-47 (2022)
institution DOAJ
collection DOAJ
language EN
topic Prostate cancer
PSMA PET/CT
MRI
Radio-recurrence
Medical physics. Medical radiology. Nuclear medicine
R895-920
Neoplasms. Tumors. Oncology. Including cancer and carcinogens
RC254-282
spellingShingle Prostate cancer
PSMA PET/CT
MRI
Radio-recurrence
Medical physics. Medical radiology. Nuclear medicine
R895-920
Neoplasms. Tumors. Oncology. Including cancer and carcinogens
RC254-282
Wei Liu
Hatim Fakir
Gurpreet Randhawa
Ryan Alfano
Mark Corkum
Zahra Kassam
Irina Rachinsky
Hans T. Chung
Peter Chung
Andrew Loblaw
Gerard Morton
Tracy Sexton
Anil Kapoor
Aaron Ward
Katherine Zukotynski
Louise Emmett
Glenn Bauman
Defining radio-recurrent intra-prostatic target volumes using PSMA-targeted PET/CT and multi-parametric MRI
description Purpose: Our purpose was to evaluate intra-prostatic cancer volumes for salvage radiotherapy in men with recurrent prostate cancer confined to the prostate post-primary radiotherapy using mpMRI and 18F-DCFPyL PET/CT (PET). Methods: Men with biochemical failure post-primary radiotherapy were enrolled in a multi-centre trial investigating mpMRI and PET. All men with isolated intra-prostatic recurrence are included in this secondary analysis. The intra-prostatic gross tumour volume (GTV) was manually delineated on mpMRI and was also delineated on PET using three methods: 1. manually, 2. using a 30% threshold of maximum intra-prostatic standard uptake value (SUVmax), and 3. using a 67% threshold of this SUVmax. Clinical target volumes (CTV) including expansions on each GTV were generated. Conformity indices were performed between the mpMRI CTV and each PET CTV. Correlation with biopsy and clinical outcomes were performed. Results: Of the 36 men included, 30 (83%) had disease in two quadrants or less using the combination of mpMRI and PET. Mean target volume (union of CTV on mpMRI and CTV manually delineated on PET) was 12.2 cc (49% of prostate gland volume). 12/36 (33%) men had a biopsy. Per-patient sensitivity was 91% for mpMRI and 82% for PET. Conclusions: mpMRI and PET provide complementary information for delineation of intra-prostatic recurrent disease. Union of CTV on mpMRI and PET is often less than 50% of the prostate, suggesting this imaging could help define a target for focal salvage therapy.
format article
author Wei Liu
Hatim Fakir
Gurpreet Randhawa
Ryan Alfano
Mark Corkum
Zahra Kassam
Irina Rachinsky
Hans T. Chung
Peter Chung
Andrew Loblaw
Gerard Morton
Tracy Sexton
Anil Kapoor
Aaron Ward
Katherine Zukotynski
Louise Emmett
Glenn Bauman
author_facet Wei Liu
Hatim Fakir
Gurpreet Randhawa
Ryan Alfano
Mark Corkum
Zahra Kassam
Irina Rachinsky
Hans T. Chung
Peter Chung
Andrew Loblaw
Gerard Morton
Tracy Sexton
Anil Kapoor
Aaron Ward
Katherine Zukotynski
Louise Emmett
Glenn Bauman
author_sort Wei Liu
title Defining radio-recurrent intra-prostatic target volumes using PSMA-targeted PET/CT and multi-parametric MRI
title_short Defining radio-recurrent intra-prostatic target volumes using PSMA-targeted PET/CT and multi-parametric MRI
title_full Defining radio-recurrent intra-prostatic target volumes using PSMA-targeted PET/CT and multi-parametric MRI
title_fullStr Defining radio-recurrent intra-prostatic target volumes using PSMA-targeted PET/CT and multi-parametric MRI
title_full_unstemmed Defining radio-recurrent intra-prostatic target volumes using PSMA-targeted PET/CT and multi-parametric MRI
title_sort defining radio-recurrent intra-prostatic target volumes using psma-targeted pet/ct and multi-parametric mri
publisher Elsevier
publishDate 2022
url https://doaj.org/article/73250c64d9e24ee19ae41b44d5798e3d
work_keys_str_mv AT weiliu definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT hatimfakir definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT gurpreetrandhawa definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT ryanalfano definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT markcorkum definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT zahrakassam definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT irinarachinsky definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT hanstchung definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT peterchung definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT andrewloblaw definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT gerardmorton definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT tracysexton definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT anilkapoor definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT aaronward definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT katherinezukotynski definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT louiseemmett definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT glennbauman definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
_version_ 1718419547855257600