Field Test on Performance of an Air Source Heat Pump System Using Novel Gravity-Driven Radiators as Indoor Heating Terminal

The simultaneous need for energy efficiency and indoor comfort may not be met by existing air source heat pump (ASHP) technology. The novelty of this study lies in the use of a new gravity-driven radiator as the indoor heating terminal of ASHPs, aiming to provide an acceptable indoor comfort with im...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Jie Jia, Xuan Zhou, Wei Feng, Yuanda Cheng, Qi Tian, Fenglei Li, Yanjun Chen, W.L. Lee
Formato: article
Lenguaje:EN
Publicado: Frontiers Media S.A. 2021
Materias:
A
Acceso en línea:https://doaj.org/article/736bde5225564cd18450727507868e5b
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:736bde5225564cd18450727507868e5b
record_format dspace
spelling oai:doaj.org-article:736bde5225564cd18450727507868e5b2021-11-19T07:52:34ZField Test on Performance of an Air Source Heat Pump System Using Novel Gravity-Driven Radiators as Indoor Heating Terminal2296-598X10.3389/fenrg.2021.765781https://doaj.org/article/736bde5225564cd18450727507868e5b2021-11-01T00:00:00Zhttps://www.frontiersin.org/articles/10.3389/fenrg.2021.765781/fullhttps://doaj.org/toc/2296-598XThe simultaneous need for energy efficiency and indoor comfort may not be met by existing air source heat pump (ASHP) technology. The novelty of this study lies in the use of a new gravity-driven radiator as the indoor heating terminal of ASHPs, aiming to provide an acceptable indoor comfort with improved energy efficiency. To confirm and quantify the performance improvement due to the proposed system retrofit, a field test was conducted to examine the system performance under real conditions. In the tests, measurements were made on the refrigerant- and air-side of the system to characterize its operational characteristics. Results showed that the proposed radiator has a rapid thermal response, which ensures a fast heat output from the system. The proposed system can create a stable and uniform indoor environment with a measured air diffusion performance index of 80%. The energy efficiency of the proposed system was also assessed based on the test data. It was found that the system’s first law efficiency is 42.5% higher than the hydraulic-based ASHP system. In terms of the second law efficiency, the compressor contributes the most to the overall system exergy loss. The exergy efficiency of the proposed system increases with the outdoor temperature and varies between 35.02 and 38.93% in the test period. The research results and the analysis methodology reported in this study will be useful for promoting the technology in search of energy efficiency improvement in residential and commercial buildings.Jie JiaXuan ZhouWei FengYuanda ChengQi TianFenglei LiYanjun ChenW.L. LeeFrontiers Media S.A.articleair source heat pumpenergy performancegravity-driven radiatorindoor comfortspace heatingGeneral WorksAENFrontiers in Energy Research, Vol 9 (2021)
institution DOAJ
collection DOAJ
language EN
topic air source heat pump
energy performance
gravity-driven radiator
indoor comfort
space heating
General Works
A
spellingShingle air source heat pump
energy performance
gravity-driven radiator
indoor comfort
space heating
General Works
A
Jie Jia
Xuan Zhou
Wei Feng
Yuanda Cheng
Qi Tian
Fenglei Li
Yanjun Chen
W.L. Lee
Field Test on Performance of an Air Source Heat Pump System Using Novel Gravity-Driven Radiators as Indoor Heating Terminal
description The simultaneous need for energy efficiency and indoor comfort may not be met by existing air source heat pump (ASHP) technology. The novelty of this study lies in the use of a new gravity-driven radiator as the indoor heating terminal of ASHPs, aiming to provide an acceptable indoor comfort with improved energy efficiency. To confirm and quantify the performance improvement due to the proposed system retrofit, a field test was conducted to examine the system performance under real conditions. In the tests, measurements were made on the refrigerant- and air-side of the system to characterize its operational characteristics. Results showed that the proposed radiator has a rapid thermal response, which ensures a fast heat output from the system. The proposed system can create a stable and uniform indoor environment with a measured air diffusion performance index of 80%. The energy efficiency of the proposed system was also assessed based on the test data. It was found that the system’s first law efficiency is 42.5% higher than the hydraulic-based ASHP system. In terms of the second law efficiency, the compressor contributes the most to the overall system exergy loss. The exergy efficiency of the proposed system increases with the outdoor temperature and varies between 35.02 and 38.93% in the test period. The research results and the analysis methodology reported in this study will be useful for promoting the technology in search of energy efficiency improvement in residential and commercial buildings.
format article
author Jie Jia
Xuan Zhou
Wei Feng
Yuanda Cheng
Qi Tian
Fenglei Li
Yanjun Chen
W.L. Lee
author_facet Jie Jia
Xuan Zhou
Wei Feng
Yuanda Cheng
Qi Tian
Fenglei Li
Yanjun Chen
W.L. Lee
author_sort Jie Jia
title Field Test on Performance of an Air Source Heat Pump System Using Novel Gravity-Driven Radiators as Indoor Heating Terminal
title_short Field Test on Performance of an Air Source Heat Pump System Using Novel Gravity-Driven Radiators as Indoor Heating Terminal
title_full Field Test on Performance of an Air Source Heat Pump System Using Novel Gravity-Driven Radiators as Indoor Heating Terminal
title_fullStr Field Test on Performance of an Air Source Heat Pump System Using Novel Gravity-Driven Radiators as Indoor Heating Terminal
title_full_unstemmed Field Test on Performance of an Air Source Heat Pump System Using Novel Gravity-Driven Radiators as Indoor Heating Terminal
title_sort field test on performance of an air source heat pump system using novel gravity-driven radiators as indoor heating terminal
publisher Frontiers Media S.A.
publishDate 2021
url https://doaj.org/article/736bde5225564cd18450727507868e5b
work_keys_str_mv AT jiejia fieldtestonperformanceofanairsourceheatpumpsystemusingnovelgravitydrivenradiatorsasindoorheatingterminal
AT xuanzhou fieldtestonperformanceofanairsourceheatpumpsystemusingnovelgravitydrivenradiatorsasindoorheatingterminal
AT weifeng fieldtestonperformanceofanairsourceheatpumpsystemusingnovelgravitydrivenradiatorsasindoorheatingterminal
AT yuandacheng fieldtestonperformanceofanairsourceheatpumpsystemusingnovelgravitydrivenradiatorsasindoorheatingterminal
AT qitian fieldtestonperformanceofanairsourceheatpumpsystemusingnovelgravitydrivenradiatorsasindoorheatingterminal
AT fengleili fieldtestonperformanceofanairsourceheatpumpsystemusingnovelgravitydrivenradiatorsasindoorheatingterminal
AT yanjunchen fieldtestonperformanceofanairsourceheatpumpsystemusingnovelgravitydrivenradiatorsasindoorheatingterminal
AT wllee fieldtestonperformanceofanairsourceheatpumpsystemusingnovelgravitydrivenradiatorsasindoorheatingterminal
_version_ 1718420265453486080