Factors Affecting Lower-pole Stretch after Breast Augmentation

Background:. Breast augmentation surgical planning based on soft-tissue characteristics including the type of lower-pole pocket direction has been described. Objective outcome measures of the effects of some of these choices on postoperative lower-pole settling, including dual-plane dissection type,...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Frederick G. Weniger, MD, MBA, FACS, Carlos E. Barrero, BS, Allan A. Weidman, BS, Sarah M. Amarillo, BA
Formato: article
Lenguaje:EN
Publicado: Wolters Kluwer 2021
Materias:
Acceso en línea:https://doaj.org/article/73efb528693c428eb6e51bd7d3a607c8
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:73efb528693c428eb6e51bd7d3a607c8
record_format dspace
spelling oai:doaj.org-article:73efb528693c428eb6e51bd7d3a607c82021-11-25T07:58:04ZFactors Affecting Lower-pole Stretch after Breast Augmentation2169-757410.1097/GOX.0000000000003865https://doaj.org/article/73efb528693c428eb6e51bd7d3a607c82021-11-01T00:00:00Zhttp://journals.lww.com/prsgo/fulltext/10.1097/GOX.0000000000003865https://doaj.org/toc/2169-7574Background:. Breast augmentation surgical planning based on soft-tissue characteristics including the type of lower-pole pocket direction has been described. Objective outcome measures of the effects of some of these choices on postoperative lower-pole settling, including dual-plane dissection type, have been lacking. Objective:. The aim of this study was to determine whether the type/extent of dual-plane dissection, patient age, or variables in breast implant characteristics affected implant–soft tissue dynamics of the lower pole of the breast enough to cause difference in implant settling during the postoperative period. Methods:. Measurements of nipple-to-inframammary fold distance in primary breast augmentation patients were collected prospectively for 227 female primary breast augmentation patients during postoperative visits over an 8-year period. Changes in this distance during the postoperative period were evaluated for correlation with dual-plane dissection type, patient age, implant fill material, implant size, and implant profile. Results:. Increasing dual-plane dissection type did demonstrate a trend toward greater postoperative lower-pole stretch. Only implant profile affected lower-pole stretch, with statistical significance shown in the ultrahigh-profile group. Age, implant fill material, and size of implant did not show any notable effect. Conclusions:. Ultrahigh-profile implants cause significantly more lower-pole stretch postoperatively, whereas increasing dual-plane dissection type appears to have some effect as well. Age, implant material, and size of implant are of less importance over a 6-month period.Frederick G. Weniger, MD, MBA, FACSCarlos E. Barrero, BSAllan A. Weidman, BSSarah M. Amarillo, BAWolters KluwerarticleSurgeryRD1-811ENPlastic and Reconstructive Surgery, Global Open, Vol 9, Iss 11, p e3865 (2021)
institution DOAJ
collection DOAJ
language EN
topic Surgery
RD1-811
spellingShingle Surgery
RD1-811
Frederick G. Weniger, MD, MBA, FACS
Carlos E. Barrero, BS
Allan A. Weidman, BS
Sarah M. Amarillo, BA
Factors Affecting Lower-pole Stretch after Breast Augmentation
description Background:. Breast augmentation surgical planning based on soft-tissue characteristics including the type of lower-pole pocket direction has been described. Objective outcome measures of the effects of some of these choices on postoperative lower-pole settling, including dual-plane dissection type, have been lacking. Objective:. The aim of this study was to determine whether the type/extent of dual-plane dissection, patient age, or variables in breast implant characteristics affected implant–soft tissue dynamics of the lower pole of the breast enough to cause difference in implant settling during the postoperative period. Methods:. Measurements of nipple-to-inframammary fold distance in primary breast augmentation patients were collected prospectively for 227 female primary breast augmentation patients during postoperative visits over an 8-year period. Changes in this distance during the postoperative period were evaluated for correlation with dual-plane dissection type, patient age, implant fill material, implant size, and implant profile. Results:. Increasing dual-plane dissection type did demonstrate a trend toward greater postoperative lower-pole stretch. Only implant profile affected lower-pole stretch, with statistical significance shown in the ultrahigh-profile group. Age, implant fill material, and size of implant did not show any notable effect. Conclusions:. Ultrahigh-profile implants cause significantly more lower-pole stretch postoperatively, whereas increasing dual-plane dissection type appears to have some effect as well. Age, implant material, and size of implant are of less importance over a 6-month period.
format article
author Frederick G. Weniger, MD, MBA, FACS
Carlos E. Barrero, BS
Allan A. Weidman, BS
Sarah M. Amarillo, BA
author_facet Frederick G. Weniger, MD, MBA, FACS
Carlos E. Barrero, BS
Allan A. Weidman, BS
Sarah M. Amarillo, BA
author_sort Frederick G. Weniger, MD, MBA, FACS
title Factors Affecting Lower-pole Stretch after Breast Augmentation
title_short Factors Affecting Lower-pole Stretch after Breast Augmentation
title_full Factors Affecting Lower-pole Stretch after Breast Augmentation
title_fullStr Factors Affecting Lower-pole Stretch after Breast Augmentation
title_full_unstemmed Factors Affecting Lower-pole Stretch after Breast Augmentation
title_sort factors affecting lower-pole stretch after breast augmentation
publisher Wolters Kluwer
publishDate 2021
url https://doaj.org/article/73efb528693c428eb6e51bd7d3a607c8
work_keys_str_mv AT frederickgwenigermdmbafacs factorsaffectinglowerpolestretchafterbreastaugmentation
AT carlosebarrerobs factorsaffectinglowerpolestretchafterbreastaugmentation
AT allanaweidmanbs factorsaffectinglowerpolestretchafterbreastaugmentation
AT sarahmamarilloba factorsaffectinglowerpolestretchafterbreastaugmentation
_version_ 1718413564855713792