Ductility Evaluation of inverted V-bracing and concentrically bracing systems

The current design philosophy for buildings located in zones with high seismic risks is that the buildings must have sufficient strength and stiffness to remain elastic and serviceable under moderate but frequently occurring earthquakes and to have sufficient ductility to prevent collapse under extr...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autor principal: Abazar Asghari
Formato: article
Lenguaje:FA
Publicado: Iranian Society of Structrual Engineering (ISSE) 2019
Materias:
Acceso en línea:https://doaj.org/article/7403bd4f4f734012b9b3830adb366452
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:7403bd4f4f734012b9b3830adb366452
record_format dspace
spelling oai:doaj.org-article:7403bd4f4f734012b9b3830adb3664522021-11-08T15:52:40ZDuctility Evaluation of inverted V-bracing and concentrically bracing systems2476-39772538-261610.22065/jsce.2018.109599.1402https://doaj.org/article/7403bd4f4f734012b9b3830adb3664522019-08-01T00:00:00Zhttps://www.jsce.ir/article_60363_89c1a82b2517ef0c08f9d7952277fc84.pdfhttps://doaj.org/toc/2476-3977https://doaj.org/toc/2538-2616The current design philosophy for buildings located in zones with high seismic risks is that the buildings must have sufficient strength and stiffness to remain elastic and serviceable under moderate but frequently occurring earthquakes and to have sufficient ductility to prevent collapse under extreme earthquakes. Conventional structural steel framing systems such as moment resisting frames (MRFs), concentrically braced frames (CBFs), and eccentrically braced frames (EBFs) I extensively used in seismically active areas. Each of the previously mentioned structural systems has different advantages and disadvantages.In this study, response modification factor of ordinary inverted V-braced frames and specially inverted V-braced frames are evaluated, result confirm that the proposed height for buildings with ordinary inverted braced frames in the ASCE7,can be increased up to 10.7 meter. also results indicate that by using ordinary inverted V-bracing systems in buildings .their height can be increased up to 6 story or 20 meter. Using special inverted V-braced systems can have saving about 0 to 30 percent on used materials for frames from 1 story to 16 stories. According to the results of this study, response modification factor proposed by Iranian seismic design code (2800 standard fourth edition),(R=5.5), is more logical than the one which is proposed by ASCE7, (R=6). Unfortunately, in special inverted V-braced frames, and when the story of the frames increases up to 12 stories, ductility demand can't be achieved .So as a result for frames which are more than 12 stories tall, lower response modification factor should be used. In addition, frames taller than 12 story height don’t experience specified target displacement and collapse before getting to preferred mechanism. This phenomenon shows the necessity of using different response modification factor for frames taller than 12 stories.Abazar AsghariIranian Society of Structrual Engineering (ISSE)articleductilityductility reduction factorconcentrically v-braced framepushover analysistarget displacementBridge engineeringTG1-470Building constructionTH1-9745FAJournal of Structural and Construction Engineering, Vol 6, Iss شماره ویژه 2, Pp 175-190 (2019)
institution DOAJ
collection DOAJ
language FA
topic ductility
ductility reduction factor
concentrically v-braced frame
pushover analysis
target displacement
Bridge engineering
TG1-470
Building construction
TH1-9745
spellingShingle ductility
ductility reduction factor
concentrically v-braced frame
pushover analysis
target displacement
Bridge engineering
TG1-470
Building construction
TH1-9745
Abazar Asghari
Ductility Evaluation of inverted V-bracing and concentrically bracing systems
description The current design philosophy for buildings located in zones with high seismic risks is that the buildings must have sufficient strength and stiffness to remain elastic and serviceable under moderate but frequently occurring earthquakes and to have sufficient ductility to prevent collapse under extreme earthquakes. Conventional structural steel framing systems such as moment resisting frames (MRFs), concentrically braced frames (CBFs), and eccentrically braced frames (EBFs) I extensively used in seismically active areas. Each of the previously mentioned structural systems has different advantages and disadvantages.In this study, response modification factor of ordinary inverted V-braced frames and specially inverted V-braced frames are evaluated, result confirm that the proposed height for buildings with ordinary inverted braced frames in the ASCE7,can be increased up to 10.7 meter. also results indicate that by using ordinary inverted V-bracing systems in buildings .their height can be increased up to 6 story or 20 meter. Using special inverted V-braced systems can have saving about 0 to 30 percent on used materials for frames from 1 story to 16 stories. According to the results of this study, response modification factor proposed by Iranian seismic design code (2800 standard fourth edition),(R=5.5), is more logical than the one which is proposed by ASCE7, (R=6). Unfortunately, in special inverted V-braced frames, and when the story of the frames increases up to 12 stories, ductility demand can't be achieved .So as a result for frames which are more than 12 stories tall, lower response modification factor should be used. In addition, frames taller than 12 story height don’t experience specified target displacement and collapse before getting to preferred mechanism. This phenomenon shows the necessity of using different response modification factor for frames taller than 12 stories.
format article
author Abazar Asghari
author_facet Abazar Asghari
author_sort Abazar Asghari
title Ductility Evaluation of inverted V-bracing and concentrically bracing systems
title_short Ductility Evaluation of inverted V-bracing and concentrically bracing systems
title_full Ductility Evaluation of inverted V-bracing and concentrically bracing systems
title_fullStr Ductility Evaluation of inverted V-bracing and concentrically bracing systems
title_full_unstemmed Ductility Evaluation of inverted V-bracing and concentrically bracing systems
title_sort ductility evaluation of inverted v-bracing and concentrically bracing systems
publisher Iranian Society of Structrual Engineering (ISSE)
publishDate 2019
url https://doaj.org/article/7403bd4f4f734012b9b3830adb366452
work_keys_str_mv AT abazarasghari ductilityevaluationofinvertedvbracingandconcentricallybracingsystems
_version_ 1718441673515597824