Analysis and Optimization of Cooling Water System Operating Cost under Changes in Ambient Temperature and Working Medium Flow
The circulating cooling water system is widely used in various industrial production fields, and its operating cost largely depends on external factors, such as ambient temperature and working medium flow. Considering the relative elevation of the heat exchanger, this study establishes a total syste...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
MDPI AG
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/7455de03f0aa407e8490e3c7e838c4be |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:7455de03f0aa407e8490e3c7e838c4be |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:7455de03f0aa407e8490e3c7e838c4be2021-11-11T15:44:31ZAnalysis and Optimization of Cooling Water System Operating Cost under Changes in Ambient Temperature and Working Medium Flow10.3390/en142169031996-1073https://doaj.org/article/7455de03f0aa407e8490e3c7e838c4be2021-10-01T00:00:00Zhttps://www.mdpi.com/1996-1073/14/21/6903https://doaj.org/toc/1996-1073The circulating cooling water system is widely used in various industrial production fields, and its operating cost largely depends on external factors, such as ambient temperature and working medium flow. Considering the relative elevation of the heat exchanger, this study establishes a total system operation cost analysis and optimization model based on the superstructure method. The model uses ambient dry bulb temperature, ambient wet bulb temperature, and working medium flow as random variables. Water supply temperature is adopted as the decision variable, and the minimum operating cost of the system is used as the objective function. An analysis of the effect of the three random variables on the operation cost shows that the effect of ambient dry bulb temperature on the operation cost is negligible, and the effect of ambient wet bulb temperature and working medium flow on the operation cost is significant. In addition, a control equation of water supply temperature is established to determine the “near optimal” operation, which is based on the correlation among ambient wet bulb temperature, working medium flow, and optimal water supply temperature. Then, the method is applied to a case system. The operating cost of the system is reduced by 22–31% at different times during the sampling day.Peng WangJinling LuQingsen CaiSenlin ChenXingqi LuoMDPI AGarticlecirculating cooling water systemoperating costambient temperatureworking medium flowoptimization modeloptimal water supply temperatureTechnologyTENEnergies, Vol 14, Iss 6903, p 6903 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
circulating cooling water system operating cost ambient temperature working medium flow optimization model optimal water supply temperature Technology T |
spellingShingle |
circulating cooling water system operating cost ambient temperature working medium flow optimization model optimal water supply temperature Technology T Peng Wang Jinling Lu Qingsen Cai Senlin Chen Xingqi Luo Analysis and Optimization of Cooling Water System Operating Cost under Changes in Ambient Temperature and Working Medium Flow |
description |
The circulating cooling water system is widely used in various industrial production fields, and its operating cost largely depends on external factors, such as ambient temperature and working medium flow. Considering the relative elevation of the heat exchanger, this study establishes a total system operation cost analysis and optimization model based on the superstructure method. The model uses ambient dry bulb temperature, ambient wet bulb temperature, and working medium flow as random variables. Water supply temperature is adopted as the decision variable, and the minimum operating cost of the system is used as the objective function. An analysis of the effect of the three random variables on the operation cost shows that the effect of ambient dry bulb temperature on the operation cost is negligible, and the effect of ambient wet bulb temperature and working medium flow on the operation cost is significant. In addition, a control equation of water supply temperature is established to determine the “near optimal” operation, which is based on the correlation among ambient wet bulb temperature, working medium flow, and optimal water supply temperature. Then, the method is applied to a case system. The operating cost of the system is reduced by 22–31% at different times during the sampling day. |
format |
article |
author |
Peng Wang Jinling Lu Qingsen Cai Senlin Chen Xingqi Luo |
author_facet |
Peng Wang Jinling Lu Qingsen Cai Senlin Chen Xingqi Luo |
author_sort |
Peng Wang |
title |
Analysis and Optimization of Cooling Water System Operating Cost under Changes in Ambient Temperature and Working Medium Flow |
title_short |
Analysis and Optimization of Cooling Water System Operating Cost under Changes in Ambient Temperature and Working Medium Flow |
title_full |
Analysis and Optimization of Cooling Water System Operating Cost under Changes in Ambient Temperature and Working Medium Flow |
title_fullStr |
Analysis and Optimization of Cooling Water System Operating Cost under Changes in Ambient Temperature and Working Medium Flow |
title_full_unstemmed |
Analysis and Optimization of Cooling Water System Operating Cost under Changes in Ambient Temperature and Working Medium Flow |
title_sort |
analysis and optimization of cooling water system operating cost under changes in ambient temperature and working medium flow |
publisher |
MDPI AG |
publishDate |
2021 |
url |
https://doaj.org/article/7455de03f0aa407e8490e3c7e838c4be |
work_keys_str_mv |
AT pengwang analysisandoptimizationofcoolingwatersystemoperatingcostunderchangesinambienttemperatureandworkingmediumflow AT jinlinglu analysisandoptimizationofcoolingwatersystemoperatingcostunderchangesinambienttemperatureandworkingmediumflow AT qingsencai analysisandoptimizationofcoolingwatersystemoperatingcostunderchangesinambienttemperatureandworkingmediumflow AT senlinchen analysisandoptimizationofcoolingwatersystemoperatingcostunderchangesinambienttemperatureandworkingmediumflow AT xingqiluo analysisandoptimizationofcoolingwatersystemoperatingcostunderchangesinambienttemperatureandworkingmediumflow |
_version_ |
1718434090380689408 |