Lifetime testing of a flexure based natural gas fired 1 kW thermoacoustic genset

Etalim has developed and lifetime tested a flexure-based thermoacoustic (TAC) genset operating at high pressure and frequency. It is an efficient and practical 1 kWe genset ready for deployment as a genset or a micro-cogeneration system when integrated with a recuperated natural gas burner and strok...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Steiner Thomas W., Hoy M., Antonelli K. B., Malekian M., Archibald G. D. S., Kanemaru T., Aitchison W., De Chardon B., Gottfried K. T., Elferink M., Henthorne T., O’Rourke B., Kostka P.
Formato: article
Lenguaje:EN
FR
Publicado: EDP Sciences 2021
Materias:
Acceso en línea:https://doaj.org/article/767e649b6f74454a916ef10f63f15052
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:Etalim has developed and lifetime tested a flexure-based thermoacoustic (TAC) genset operating at high pressure and frequency. It is an efficient and practical 1 kWe genset ready for deployment as a genset or a micro-cogeneration system when integrated with a recuperated natural gas burner and stroke controlling power electronics. It is a maintenancefree, extreme reliability genset particularly suited for remote power applications. The genset is fully costed and designed for manufacturing. Fuel-to-electric efficiency of 22% has been achieved, and one remaining avenue for significant improvement identified. A test TAC has been run for a cumulative time of about 8000 hours to date without any component failures.