The effects of lubricant eye drops on visual function as measured by the Inter-blink interval Visual Acuity Decay test
Gail TorkildsenAndover Eye Associates, Andover, MA, USAObjective: The purpose of the current study was to evaluate the effects of two marketed ocular lubricants on the visual decay in dry eye patients using the Inter-blink interval Visual Acuity Decay (IVAD) test.Methods: This controlled, randomized...
Guardado en:
Autor principal: | |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2009
|
Materias: | |
Acceso en línea: | https://doaj.org/article/778f943caa9844d2aacd2ed1a9e7c80a |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:778f943caa9844d2aacd2ed1a9e7c80a |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:778f943caa9844d2aacd2ed1a9e7c80a2021-12-02T07:12:20ZThe effects of lubricant eye drops on visual function as measured by the Inter-blink interval Visual Acuity Decay test1177-54671177-5483https://doaj.org/article/778f943caa9844d2aacd2ed1a9e7c80a2009-09-01T00:00:00Zhttp://www.dovepress.com/the-effects-of-lubricant-eye-drops-on-visual-function-as-measured-by-t-a3536https://doaj.org/toc/1177-5467https://doaj.org/toc/1177-5483Gail TorkildsenAndover Eye Associates, Andover, MA, USAObjective: The purpose of the current study was to evaluate the effects of two marketed ocular lubricants on the visual decay in dry eye patients using the Inter-blink interval Visual Acuity Decay (IVAD) test.Methods: This controlled, randomized, double-masked crossover study compared the effects of a polyethylene glycol/propylene glycol-based (PEG/PG) tear and a carboxymethylcellulose sodium (CMC)/glycerin tear on the visual acuity decay between blinks of dry eye patients. At visit 1 (Day 0), baseline IVAD measurements were recorded prior to instillation of a single drop of randomized study medication. IVAD testing was repeated at 15-, 45-, and 90-minutes post-instillation. Reading rate and functional blink rate were also evaluated. At the second visit (Day 7 ± 3), study procedures were repeated using crossover treatment.Results: Forty-eight (48) subjects with dry eye (61.1 ± 14.8 years old, 79.2% female, 95.8% white) completed the study. Treatment with the PEG/PG-based tear demonstrated statistically significantly longer time to one-line loss of best-corrected visual acuity (BCVA) as determined by the IVAD test at 90 minutes post-instillation compared to the CMC/glycerin tear (P = 0.0365). Measurements of median time at BCVA, reading rate, and functional blink rate were similar for both treatments. Both formulations were well tolerated in the population studied.Conclusions: Treatment with the PEG/PG-based tear demonstrated statistically significant improved maintenance of visual acuity between blinks at 90 minutes post-instillation compared to the CMC/glycerin tear. This is the first study to demonstrate the ability of an artificial tear to extend visual acuity maintenance between blinks, as measured by the IVAD test.Keywords: dry eye, visual function, artificial tears, ocular lubricant Gail TorkildsenDove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2009, Iss default, Pp 501-506 (2009) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Ophthalmology RE1-994 |
spellingShingle |
Ophthalmology RE1-994 Gail Torkildsen The effects of lubricant eye drops on visual function as measured by the Inter-blink interval Visual Acuity Decay test |
description |
Gail TorkildsenAndover Eye Associates, Andover, MA, USAObjective: The purpose of the current study was to evaluate the effects of two marketed ocular lubricants on the visual decay in dry eye patients using the Inter-blink interval Visual Acuity Decay (IVAD) test.Methods: This controlled, randomized, double-masked crossover study compared the effects of a polyethylene glycol/propylene glycol-based (PEG/PG) tear and a carboxymethylcellulose sodium (CMC)/glycerin tear on the visual acuity decay between blinks of dry eye patients. At visit 1 (Day 0), baseline IVAD measurements were recorded prior to instillation of a single drop of randomized study medication. IVAD testing was repeated at 15-, 45-, and 90-minutes post-instillation. Reading rate and functional blink rate were also evaluated. At the second visit (Day 7 ± 3), study procedures were repeated using crossover treatment.Results: Forty-eight (48) subjects with dry eye (61.1 ± 14.8 years old, 79.2% female, 95.8% white) completed the study. Treatment with the PEG/PG-based tear demonstrated statistically significantly longer time to one-line loss of best-corrected visual acuity (BCVA) as determined by the IVAD test at 90 minutes post-instillation compared to the CMC/glycerin tear (P = 0.0365). Measurements of median time at BCVA, reading rate, and functional blink rate were similar for both treatments. Both formulations were well tolerated in the population studied.Conclusions: Treatment with the PEG/PG-based tear demonstrated statistically significant improved maintenance of visual acuity between blinks at 90 minutes post-instillation compared to the CMC/glycerin tear. This is the first study to demonstrate the ability of an artificial tear to extend visual acuity maintenance between blinks, as measured by the IVAD test.Keywords: dry eye, visual function, artificial tears, ocular lubricant |
format |
article |
author |
Gail Torkildsen |
author_facet |
Gail Torkildsen |
author_sort |
Gail Torkildsen |
title |
The effects of lubricant eye drops on visual function as measured by the Inter-blink interval Visual Acuity Decay test |
title_short |
The effects of lubricant eye drops on visual function as measured by the Inter-blink interval Visual Acuity Decay test |
title_full |
The effects of lubricant eye drops on visual function as measured by the Inter-blink interval Visual Acuity Decay test |
title_fullStr |
The effects of lubricant eye drops on visual function as measured by the Inter-blink interval Visual Acuity Decay test |
title_full_unstemmed |
The effects of lubricant eye drops on visual function as measured by the Inter-blink interval Visual Acuity Decay test |
title_sort |
effects of lubricant eye drops on visual function as measured by the inter-blink interval visual acuity decay test |
publisher |
Dove Medical Press |
publishDate |
2009 |
url |
https://doaj.org/article/778f943caa9844d2aacd2ed1a9e7c80a |
work_keys_str_mv |
AT gailtorkildsen theeffectsoflubricanteyedropsonvisualfunctionasmeasuredbytheinterblinkintervalvisualacuitydecaytest AT gailtorkildsen effectsoflubricanteyedropsonvisualfunctionasmeasuredbytheinterblinkintervalvisualacuitydecaytest |
_version_ |
1718399578767622144 |