Comparative analysis of conventional and new seismically isolated structure
Extensive analytical and experimental research has been done by the authors directed to mitigation of the effects of earthquakes on structures. The research results mainly represent parts of the realized several related international projects. A selected part of the analytical studies directed to co...
Guardado en:
Autores principales: | , , , |
---|---|
Formato: | article |
Lenguaje: | EN SR |
Publicado: |
Society for Materials and Structures testing of Serbia
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/787723a9c60a4ac3b3d2b5db214d95c5 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:787723a9c60a4ac3b3d2b5db214d95c5 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:787723a9c60a4ac3b3d2b5db214d95c52021-12-05T21:10:35ZComparative analysis of conventional and new seismically isolated structure2217-81392335-022910.5937/GRMK2103185Rhttps://doaj.org/article/787723a9c60a4ac3b3d2b5db214d95c52021-01-01T00:00:00Zhttps://scindeks-clanci.ceon.rs/data/pdf/2217-8139/2021/2217-81392103185R.pdfhttps://doaj.org/toc/2217-8139https://doaj.org/toc/2335-0229Extensive analytical and experimental research has been done by the authors directed to mitigation of the effects of earthquakes on structures. The research results mainly represent parts of the realized several related international projects. A selected part of the analytical studies directed to comparison between conventional and seismically isolated frame structures is presented in this paper. The responses of the applied newely developed advanced seismic isolation system HC-RMS-GOSEB to the simulated input excitation of three representative earthquakes of intensity 0.50g, have shown that it is very effective for construction of vibro-isolated and seismically resistant buildings, providing activated multistage seismic response and globally optimized seismic energy balance. Its application achieves an increase in the vibration period of the structure, far enough from the dominant period of seismic excitation. The results of the research confirm that this system is a potential solution for achieving low-cost and highly efficient protection of buildings.Ristić JelenaVučinić MilošRistić DaniloVučinić MilutinSociety for Materials and Structures testing of Serbiaarticleearthquakebuildingseismic isolationenergy dissipationnonlinear modelseismic safetyEngineering (General). Civil engineering (General)TA1-2040ENSRGrađevinski Materijali i Konstrukcije, Vol 64, Iss 3, Pp 185-193 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN SR |
topic |
earthquake building seismic isolation energy dissipation nonlinear model seismic safety Engineering (General). Civil engineering (General) TA1-2040 |
spellingShingle |
earthquake building seismic isolation energy dissipation nonlinear model seismic safety Engineering (General). Civil engineering (General) TA1-2040 Ristić Jelena Vučinić Miloš Ristić Danilo Vučinić Milutin Comparative analysis of conventional and new seismically isolated structure |
description |
Extensive analytical and experimental research has been done by the authors directed to mitigation of the effects of earthquakes on structures. The research results mainly represent parts of the realized several related international projects. A selected part of the analytical studies directed to comparison between conventional and seismically isolated frame structures is presented in this paper. The responses of the applied newely developed advanced seismic isolation system HC-RMS-GOSEB to the simulated input excitation of three representative earthquakes of intensity 0.50g, have shown that it is very effective for construction of vibro-isolated and seismically resistant buildings, providing activated multistage seismic response and globally optimized seismic energy balance. Its application achieves an increase in the vibration period of the structure, far enough from the dominant period of seismic excitation. The results of the research confirm that this system is a potential solution for achieving low-cost and highly efficient protection of buildings. |
format |
article |
author |
Ristić Jelena Vučinić Miloš Ristić Danilo Vučinić Milutin |
author_facet |
Ristić Jelena Vučinić Miloš Ristić Danilo Vučinić Milutin |
author_sort |
Ristić Jelena |
title |
Comparative analysis of conventional and new seismically isolated structure |
title_short |
Comparative analysis of conventional and new seismically isolated structure |
title_full |
Comparative analysis of conventional and new seismically isolated structure |
title_fullStr |
Comparative analysis of conventional and new seismically isolated structure |
title_full_unstemmed |
Comparative analysis of conventional and new seismically isolated structure |
title_sort |
comparative analysis of conventional and new seismically isolated structure |
publisher |
Society for Materials and Structures testing of Serbia |
publishDate |
2021 |
url |
https://doaj.org/article/787723a9c60a4ac3b3d2b5db214d95c5 |
work_keys_str_mv |
AT risticjelena comparativeanalysisofconventionalandnewseismicallyisolatedstructure AT vucinicmilos comparativeanalysisofconventionalandnewseismicallyisolatedstructure AT risticdanilo comparativeanalysisofconventionalandnewseismicallyisolatedstructure AT vucinicmilutin comparativeanalysisofconventionalandnewseismicallyisolatedstructure |
_version_ |
1718371009435795456 |