Comparative analysis of conventional and new seismically isolated structure

Extensive analytical and experimental research has been done by the authors directed to mitigation of the effects of earthquakes on structures. The research results mainly represent parts of the realized several related international projects. A selected part of the analytical studies directed to co...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Ristić Jelena, Vučinić Miloš, Ristić Danilo, Vučinić Milutin
Formato: article
Lenguaje:EN
SR
Publicado: Society for Materials and Structures testing of Serbia 2021
Materias:
Acceso en línea:https://doaj.org/article/787723a9c60a4ac3b3d2b5db214d95c5
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:787723a9c60a4ac3b3d2b5db214d95c5
record_format dspace
spelling oai:doaj.org-article:787723a9c60a4ac3b3d2b5db214d95c52021-12-05T21:10:35ZComparative analysis of conventional and new seismically isolated structure2217-81392335-022910.5937/GRMK2103185Rhttps://doaj.org/article/787723a9c60a4ac3b3d2b5db214d95c52021-01-01T00:00:00Zhttps://scindeks-clanci.ceon.rs/data/pdf/2217-8139/2021/2217-81392103185R.pdfhttps://doaj.org/toc/2217-8139https://doaj.org/toc/2335-0229Extensive analytical and experimental research has been done by the authors directed to mitigation of the effects of earthquakes on structures. The research results mainly represent parts of the realized several related international projects. A selected part of the analytical studies directed to comparison between conventional and seismically isolated frame structures is presented in this paper. The responses of the applied newely developed advanced seismic isolation system HC-RMS-GOSEB to the simulated input excitation of three representative earthquakes of intensity 0.50g, have shown that it is very effective for construction of vibro-isolated and seismically resistant buildings, providing activated multistage seismic response and globally optimized seismic energy balance. Its application achieves an increase in the vibration period of the structure, far enough from the dominant period of seismic excitation. The results of the research confirm that this system is a potential solution for achieving low-cost and highly efficient protection of buildings.Ristić JelenaVučinić MilošRistić DaniloVučinić MilutinSociety for Materials and Structures testing of Serbiaarticleearthquakebuildingseismic isolationenergy dissipationnonlinear modelseismic safetyEngineering (General). Civil engineering (General)TA1-2040ENSRGrađevinski Materijali i Konstrukcije, Vol 64, Iss 3, Pp 185-193 (2021)
institution DOAJ
collection DOAJ
language EN
SR
topic earthquake
building
seismic isolation
energy dissipation
nonlinear model
seismic safety
Engineering (General). Civil engineering (General)
TA1-2040
spellingShingle earthquake
building
seismic isolation
energy dissipation
nonlinear model
seismic safety
Engineering (General). Civil engineering (General)
TA1-2040
Ristić Jelena
Vučinić Miloš
Ristić Danilo
Vučinić Milutin
Comparative analysis of conventional and new seismically isolated structure
description Extensive analytical and experimental research has been done by the authors directed to mitigation of the effects of earthquakes on structures. The research results mainly represent parts of the realized several related international projects. A selected part of the analytical studies directed to comparison between conventional and seismically isolated frame structures is presented in this paper. The responses of the applied newely developed advanced seismic isolation system HC-RMS-GOSEB to the simulated input excitation of three representative earthquakes of intensity 0.50g, have shown that it is very effective for construction of vibro-isolated and seismically resistant buildings, providing activated multistage seismic response and globally optimized seismic energy balance. Its application achieves an increase in the vibration period of the structure, far enough from the dominant period of seismic excitation. The results of the research confirm that this system is a potential solution for achieving low-cost and highly efficient protection of buildings.
format article
author Ristić Jelena
Vučinić Miloš
Ristić Danilo
Vučinić Milutin
author_facet Ristić Jelena
Vučinić Miloš
Ristić Danilo
Vučinić Milutin
author_sort Ristić Jelena
title Comparative analysis of conventional and new seismically isolated structure
title_short Comparative analysis of conventional and new seismically isolated structure
title_full Comparative analysis of conventional and new seismically isolated structure
title_fullStr Comparative analysis of conventional and new seismically isolated structure
title_full_unstemmed Comparative analysis of conventional and new seismically isolated structure
title_sort comparative analysis of conventional and new seismically isolated structure
publisher Society for Materials and Structures testing of Serbia
publishDate 2021
url https://doaj.org/article/787723a9c60a4ac3b3d2b5db214d95c5
work_keys_str_mv AT risticjelena comparativeanalysisofconventionalandnewseismicallyisolatedstructure
AT vucinicmilos comparativeanalysisofconventionalandnewseismicallyisolatedstructure
AT risticdanilo comparativeanalysisofconventionalandnewseismicallyisolatedstructure
AT vucinicmilutin comparativeanalysisofconventionalandnewseismicallyisolatedstructure
_version_ 1718371009435795456