Validity and reliability of the ‘Isometric Exercise Scale’ (IES) for measuring ratings of perceived exertion during continuous isometric exercise

Abstract Isometric exercise (IE) interventions are an effective non-medical method of reducing arterial blood pressure (BP). Current methods of prescribing and controlling isometric exercise intensity often require the use of expensive equipment and specialist knowledge. However, ratings of perceive...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: John W. D. Lea, Jamie M. O’Driscoll, Damian A. Coleman, Jonathan D. Wiles
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/788bdf40703c4e868cab96c8b54d88ca
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:788bdf40703c4e868cab96c8b54d88ca
record_format dspace
spelling oai:doaj.org-article:788bdf40703c4e868cab96c8b54d88ca2021-12-02T11:37:27ZValidity and reliability of the ‘Isometric Exercise Scale’ (IES) for measuring ratings of perceived exertion during continuous isometric exercise10.1038/s41598-021-84803-82045-2322https://doaj.org/article/788bdf40703c4e868cab96c8b54d88ca2021-03-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-84803-8https://doaj.org/toc/2045-2322Abstract Isometric exercise (IE) interventions are an effective non-medical method of reducing arterial blood pressure (BP). Current methods of prescribing and controlling isometric exercise intensity often require the use of expensive equipment and specialist knowledge. However, ratings of perceived exertion (RPE) may provide a more accessible means of monitoring exercise intensity. Therefore, the aim of this study was to assess the validity of a specific Isometric Exercise Scale (IES) during a continuous incremental IE test. Twenty-nine male participants completed four incremental isometric wall squat tests. Each test consisted of five 2-min stages of progressively increasing workload. Workload was determined by knee joint angle from 135° to 95°. The tests were continuous with no rest periods between the stages. Throughout the exercise protocol, RPE (IES and Borg’s CR-10), heart rate and blood pressure were recorded. A strong positive linear relationship was found between the IES and the CR-10 (r = 0.967). Likewise, strong positive relationships between the IES and wall squat duration (r = 0.849), HR (r = 0.819) and BP (r = 0.841) were seen. Intra-class correlation coefficients and coefficients of variations for the IES ranged from r = 0.81 to 0.91 and 4.5–54%, respectively, with greater reliability seen at the higher workloads. The IES provides valid and reliable measurements of RPE, exercise intensity, and the changes in physiological measures of exertion during continuous incremental IE; as such, the IES can be used as an accessible measure of exercise intensity during IE interventions.John W. D. LeaJamie M. O’DriscollDamian A. ColemanJonathan D. WilesNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-9 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
John W. D. Lea
Jamie M. O’Driscoll
Damian A. Coleman
Jonathan D. Wiles
Validity and reliability of the ‘Isometric Exercise Scale’ (IES) for measuring ratings of perceived exertion during continuous isometric exercise
description Abstract Isometric exercise (IE) interventions are an effective non-medical method of reducing arterial blood pressure (BP). Current methods of prescribing and controlling isometric exercise intensity often require the use of expensive equipment and specialist knowledge. However, ratings of perceived exertion (RPE) may provide a more accessible means of monitoring exercise intensity. Therefore, the aim of this study was to assess the validity of a specific Isometric Exercise Scale (IES) during a continuous incremental IE test. Twenty-nine male participants completed four incremental isometric wall squat tests. Each test consisted of five 2-min stages of progressively increasing workload. Workload was determined by knee joint angle from 135° to 95°. The tests were continuous with no rest periods between the stages. Throughout the exercise protocol, RPE (IES and Borg’s CR-10), heart rate and blood pressure were recorded. A strong positive linear relationship was found between the IES and the CR-10 (r = 0.967). Likewise, strong positive relationships between the IES and wall squat duration (r = 0.849), HR (r = 0.819) and BP (r = 0.841) were seen. Intra-class correlation coefficients and coefficients of variations for the IES ranged from r = 0.81 to 0.91 and 4.5–54%, respectively, with greater reliability seen at the higher workloads. The IES provides valid and reliable measurements of RPE, exercise intensity, and the changes in physiological measures of exertion during continuous incremental IE; as such, the IES can be used as an accessible measure of exercise intensity during IE interventions.
format article
author John W. D. Lea
Jamie M. O’Driscoll
Damian A. Coleman
Jonathan D. Wiles
author_facet John W. D. Lea
Jamie M. O’Driscoll
Damian A. Coleman
Jonathan D. Wiles
author_sort John W. D. Lea
title Validity and reliability of the ‘Isometric Exercise Scale’ (IES) for measuring ratings of perceived exertion during continuous isometric exercise
title_short Validity and reliability of the ‘Isometric Exercise Scale’ (IES) for measuring ratings of perceived exertion during continuous isometric exercise
title_full Validity and reliability of the ‘Isometric Exercise Scale’ (IES) for measuring ratings of perceived exertion during continuous isometric exercise
title_fullStr Validity and reliability of the ‘Isometric Exercise Scale’ (IES) for measuring ratings of perceived exertion during continuous isometric exercise
title_full_unstemmed Validity and reliability of the ‘Isometric Exercise Scale’ (IES) for measuring ratings of perceived exertion during continuous isometric exercise
title_sort validity and reliability of the ‘isometric exercise scale’ (ies) for measuring ratings of perceived exertion during continuous isometric exercise
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/788bdf40703c4e868cab96c8b54d88ca
work_keys_str_mv AT johnwdlea validityandreliabilityoftheisometricexercisescaleiesformeasuringratingsofperceivedexertionduringcontinuousisometricexercise
AT jamiemodriscoll validityandreliabilityoftheisometricexercisescaleiesformeasuringratingsofperceivedexertionduringcontinuousisometricexercise
AT damianacoleman validityandreliabilityoftheisometricexercisescaleiesformeasuringratingsofperceivedexertionduringcontinuousisometricexercise
AT jonathandwiles validityandreliabilityoftheisometricexercisescaleiesformeasuringratingsofperceivedexertionduringcontinuousisometricexercise
_version_ 1718395766967369728