Measuring molecular frequencies in the 1–10 μm range at 11-digits accuracy

Abstract High-resolution spectroscopy in the 1–10 μm region has never been fully tackled for the lack of widely-tunable and practical light sources. Indeed, all solutions proposed thus far suffer from at least one of three issues: they are feasible only in a narrow spectral range; the power availabl...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: G. Insero, S. Borri, D. Calonico, P. Cancio Pastor, C. Clivati, D. D’Ambrosio, P. De Natale, M. Inguscio, F. Levi, G. Santambrogio
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2017
Materias:
R
Q
Acceso en línea:https://doaj.org/article/78f46995b7384b7db799d88419d4af6b
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:78f46995b7384b7db799d88419d4af6b
record_format dspace
spelling oai:doaj.org-article:78f46995b7384b7db799d88419d4af6b2021-12-02T15:06:25ZMeasuring molecular frequencies in the 1–10 μm range at 11-digits accuracy10.1038/s41598-017-12891-62045-2322https://doaj.org/article/78f46995b7384b7db799d88419d4af6b2017-10-01T00:00:00Zhttps://doi.org/10.1038/s41598-017-12891-6https://doaj.org/toc/2045-2322Abstract High-resolution spectroscopy in the 1–10 μm region has never been fully tackled for the lack of widely-tunable and practical light sources. Indeed, all solutions proposed thus far suffer from at least one of three issues: they are feasible only in a narrow spectral range; the power available for spectroscopy is limited; the frequency accuracy is poor. Here, we present a setup for high-resolution spectroscopy, whose approach can be applied in the whole 1–10 μm range. It combines the power of quantum cascade lasers (QCLs) and the accuracy achievable by difference frequency generation using an orientation patterned GaP crystal. The frequency is measured against a primary frequency standard using the Italian metrological fibre link network. We demonstrate the performance of the setup by measuring a vibrational transition in a highly-excited metastable state of CO around 6 μm with 11 digits of precision.G. InseroS. BorriD. CalonicoP. Cancio PastorC. ClivatiD. D’AmbrosioP. De NataleM. InguscioF. LeviG. SantambrogioNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 7, Iss 1, Pp 1-7 (2017)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
G. Insero
S. Borri
D. Calonico
P. Cancio Pastor
C. Clivati
D. D’Ambrosio
P. De Natale
M. Inguscio
F. Levi
G. Santambrogio
Measuring molecular frequencies in the 1–10 μm range at 11-digits accuracy
description Abstract High-resolution spectroscopy in the 1–10 μm region has never been fully tackled for the lack of widely-tunable and practical light sources. Indeed, all solutions proposed thus far suffer from at least one of three issues: they are feasible only in a narrow spectral range; the power available for spectroscopy is limited; the frequency accuracy is poor. Here, we present a setup for high-resolution spectroscopy, whose approach can be applied in the whole 1–10 μm range. It combines the power of quantum cascade lasers (QCLs) and the accuracy achievable by difference frequency generation using an orientation patterned GaP crystal. The frequency is measured against a primary frequency standard using the Italian metrological fibre link network. We demonstrate the performance of the setup by measuring a vibrational transition in a highly-excited metastable state of CO around 6 μm with 11 digits of precision.
format article
author G. Insero
S. Borri
D. Calonico
P. Cancio Pastor
C. Clivati
D. D’Ambrosio
P. De Natale
M. Inguscio
F. Levi
G. Santambrogio
author_facet G. Insero
S. Borri
D. Calonico
P. Cancio Pastor
C. Clivati
D. D’Ambrosio
P. De Natale
M. Inguscio
F. Levi
G. Santambrogio
author_sort G. Insero
title Measuring molecular frequencies in the 1–10 μm range at 11-digits accuracy
title_short Measuring molecular frequencies in the 1–10 μm range at 11-digits accuracy
title_full Measuring molecular frequencies in the 1–10 μm range at 11-digits accuracy
title_fullStr Measuring molecular frequencies in the 1–10 μm range at 11-digits accuracy
title_full_unstemmed Measuring molecular frequencies in the 1–10 μm range at 11-digits accuracy
title_sort measuring molecular frequencies in the 1–10 μm range at 11-digits accuracy
publisher Nature Portfolio
publishDate 2017
url https://doaj.org/article/78f46995b7384b7db799d88419d4af6b
work_keys_str_mv AT ginsero measuringmolecularfrequenciesinthe110mmrangeat11digitsaccuracy
AT sborri measuringmolecularfrequenciesinthe110mmrangeat11digitsaccuracy
AT dcalonico measuringmolecularfrequenciesinthe110mmrangeat11digitsaccuracy
AT pcanciopastor measuringmolecularfrequenciesinthe110mmrangeat11digitsaccuracy
AT cclivati measuringmolecularfrequenciesinthe110mmrangeat11digitsaccuracy
AT ddambrosio measuringmolecularfrequenciesinthe110mmrangeat11digitsaccuracy
AT pdenatale measuringmolecularfrequenciesinthe110mmrangeat11digitsaccuracy
AT minguscio measuringmolecularfrequenciesinthe110mmrangeat11digitsaccuracy
AT flevi measuringmolecularfrequenciesinthe110mmrangeat11digitsaccuracy
AT gsantambrogio measuringmolecularfrequenciesinthe110mmrangeat11digitsaccuracy
_version_ 1718388456959246336