Commercially available rigid gas-permeable contact lens for protecting the cornea from drying during vitrectomy with a wide viewing system

Motohiro Kamei, Nagakazu Matsumura, Hirokazu Sakaguchi, Yusuke Oshima, Yasushi Ikuno, Kohji NishidaDepartment of Ophthalmology, Osaka University Graduate School of Medicine, Osaka, JapanPurpose: We evaluated the usefulness of commercially available materials for protecting the cornea from drying dur...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Kamei M, Matsumura N, Sakaguchi H, Oshima Y, Ikuno Y, Nishida K
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2012
Materias:
Acceso en línea:https://doaj.org/article/79b62acae01249c9bc6fd5c4a120e0d5
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:79b62acae01249c9bc6fd5c4a120e0d5
record_format dspace
spelling oai:doaj.org-article:79b62acae01249c9bc6fd5c4a120e0d52021-12-02T00:13:46ZCommercially available rigid gas-permeable contact lens for protecting the cornea from drying during vitrectomy with a wide viewing system1177-54671177-5483https://doaj.org/article/79b62acae01249c9bc6fd5c4a120e0d52012-08-01T00:00:00Zhttp://www.dovepress.com/commercially-available-rigid-gas-permeable-contact-lens-for-protecting-a10694https://doaj.org/toc/1177-5467https://doaj.org/toc/1177-5483Motohiro Kamei, Nagakazu Matsumura, Hirokazu Sakaguchi, Yusuke Oshima, Yasushi Ikuno, Kohji NishidaDepartment of Ophthalmology, Osaka University Graduate School of Medicine, Osaka, JapanPurpose: We evaluated the usefulness of commercially available materials for protecting the cornea from drying during vitrectomy with a wide-angle viewing system.Methods: Three vitreoretinal surgeons evaluated fundus visibility during vitrectomy on the images of five study materials used on the cornea: balanced saline solution, a viscoelastic agent, a vitrectomy contact lens, a rigid gas permeable (RGP) contact lens, and a soft contact lens. Fundus visibility was graded using the following scale: grade 1, unclear; grade 2, slightly unclear; grade 3, clear; and grade 4, very clear.Results: Respective scores for each material used during core vitrectomy and membrane removal were: balanced saline solution, 3.3/3.3; viscoelastic agent, 3.8/3.3; vitrectomy contact lens, 3.3/4.0; RGP contact lens, 4.0/3.9; soft contact lens, 1.1/not applicable.Conclusion: The RGP contact lens provided visibility similar to or clearer than that obtained with other methods. Because of its ease of use and lower cost, use of the RGP contact lens is ideal during vitrectomy performed with a wide-angle viewing system.Keywords: contact lens, RGP, viscoelastic agent, vitrectomy, wide viewing systemKamei MMatsumura NSakaguchi HOshima YIkuno YNishida KDove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2012, Iss default, Pp 1321-1324 (2012)
institution DOAJ
collection DOAJ
language EN
topic Ophthalmology
RE1-994
spellingShingle Ophthalmology
RE1-994
Kamei M
Matsumura N
Sakaguchi H
Oshima Y
Ikuno Y
Nishida K
Commercially available rigid gas-permeable contact lens for protecting the cornea from drying during vitrectomy with a wide viewing system
description Motohiro Kamei, Nagakazu Matsumura, Hirokazu Sakaguchi, Yusuke Oshima, Yasushi Ikuno, Kohji NishidaDepartment of Ophthalmology, Osaka University Graduate School of Medicine, Osaka, JapanPurpose: We evaluated the usefulness of commercially available materials for protecting the cornea from drying during vitrectomy with a wide-angle viewing system.Methods: Three vitreoretinal surgeons evaluated fundus visibility during vitrectomy on the images of five study materials used on the cornea: balanced saline solution, a viscoelastic agent, a vitrectomy contact lens, a rigid gas permeable (RGP) contact lens, and a soft contact lens. Fundus visibility was graded using the following scale: grade 1, unclear; grade 2, slightly unclear; grade 3, clear; and grade 4, very clear.Results: Respective scores for each material used during core vitrectomy and membrane removal were: balanced saline solution, 3.3/3.3; viscoelastic agent, 3.8/3.3; vitrectomy contact lens, 3.3/4.0; RGP contact lens, 4.0/3.9; soft contact lens, 1.1/not applicable.Conclusion: The RGP contact lens provided visibility similar to or clearer than that obtained with other methods. Because of its ease of use and lower cost, use of the RGP contact lens is ideal during vitrectomy performed with a wide-angle viewing system.Keywords: contact lens, RGP, viscoelastic agent, vitrectomy, wide viewing system
format article
author Kamei M
Matsumura N
Sakaguchi H
Oshima Y
Ikuno Y
Nishida K
author_facet Kamei M
Matsumura N
Sakaguchi H
Oshima Y
Ikuno Y
Nishida K
author_sort Kamei M
title Commercially available rigid gas-permeable contact lens for protecting the cornea from drying during vitrectomy with a wide viewing system
title_short Commercially available rigid gas-permeable contact lens for protecting the cornea from drying during vitrectomy with a wide viewing system
title_full Commercially available rigid gas-permeable contact lens for protecting the cornea from drying during vitrectomy with a wide viewing system
title_fullStr Commercially available rigid gas-permeable contact lens for protecting the cornea from drying during vitrectomy with a wide viewing system
title_full_unstemmed Commercially available rigid gas-permeable contact lens for protecting the cornea from drying during vitrectomy with a wide viewing system
title_sort commercially available rigid gas-permeable contact lens for protecting the cornea from drying during vitrectomy with a wide viewing system
publisher Dove Medical Press
publishDate 2012
url https://doaj.org/article/79b62acae01249c9bc6fd5c4a120e0d5
work_keys_str_mv AT kameim commerciallyavailablerigidgaspermeablecontactlensforprotectingthecorneafromdryingduringvitrectomywithawideviewingsystem
AT matsumuran commerciallyavailablerigidgaspermeablecontactlensforprotectingthecorneafromdryingduringvitrectomywithawideviewingsystem
AT sakaguchih commerciallyavailablerigidgaspermeablecontactlensforprotectingthecorneafromdryingduringvitrectomywithawideviewingsystem
AT oshimay commerciallyavailablerigidgaspermeablecontactlensforprotectingthecorneafromdryingduringvitrectomywithawideviewingsystem
AT ikunoy commerciallyavailablerigidgaspermeablecontactlensforprotectingthecorneafromdryingduringvitrectomywithawideviewingsystem
AT nishidak commerciallyavailablerigidgaspermeablecontactlensforprotectingthecorneafromdryingduringvitrectomywithawideviewingsystem
_version_ 1718403872457752576