Multi-volume hemacytometer
Abstract Cell counting has become an essential method for monitoring the viability and proliferation of cells. A hemacytometer is the standard device used to measure cell numbers in most laboratories which are typically automated to increase throughput. The principle of both manual and automated hem...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/79d980e82a23455381918ede650b3f3e |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:79d980e82a23455381918ede650b3f3e |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:79d980e82a23455381918ede650b3f3e2021-12-02T18:34:13ZMulti-volume hemacytometer10.1038/s41598-021-93477-12045-2322https://doaj.org/article/79d980e82a23455381918ede650b3f3e2021-07-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-93477-1https://doaj.org/toc/2045-2322Abstract Cell counting has become an essential method for monitoring the viability and proliferation of cells. A hemacytometer is the standard device used to measure cell numbers in most laboratories which are typically automated to increase throughput. The principle of both manual and automated hemacytometers is to calculate cell numbers with a fixed volume within a set measurement range (105 ~ 106 cells/ml). If the cell concentration of the unknown sample is outside the range of the hemacytometer, the sample must be prepared again by increasing or decreasing the cell concentration. We have developed a new hemacytometer that has a multi-volume chamber with 4 different depths containing different volumes (0.1, 0.2, 0.4, 0.8 µl respectively). A multi-volume hemacytometer can measure cell concentration with a maximum of 106 cells/ml to a minimum of 5 × 103 cells/ml. Compared to a typical hemacytometer with a fixed volume of 0.1 µl, the minimum measurable cell concentration of 5 × 103 cells/ml on the multi-volume hemacytometer is twenty times lower. Additionally, the Multi-Volume Cell Counting model (cell concentration calculation with the slope value of cell number in multi-chambers) showed a wide measurement range (5 × 103 ~ 1 × 106 cells/ml) while reducing total cell counting numbers by 62.5% compared to a large volume (0.8 µl-chamber) hemacytometer.Ravangnam ThunyapornIl DohDong Woo LeeNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-9 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Ravangnam Thunyaporn Il Doh Dong Woo Lee Multi-volume hemacytometer |
description |
Abstract Cell counting has become an essential method for monitoring the viability and proliferation of cells. A hemacytometer is the standard device used to measure cell numbers in most laboratories which are typically automated to increase throughput. The principle of both manual and automated hemacytometers is to calculate cell numbers with a fixed volume within a set measurement range (105 ~ 106 cells/ml). If the cell concentration of the unknown sample is outside the range of the hemacytometer, the sample must be prepared again by increasing or decreasing the cell concentration. We have developed a new hemacytometer that has a multi-volume chamber with 4 different depths containing different volumes (0.1, 0.2, 0.4, 0.8 µl respectively). A multi-volume hemacytometer can measure cell concentration with a maximum of 106 cells/ml to a minimum of 5 × 103 cells/ml. Compared to a typical hemacytometer with a fixed volume of 0.1 µl, the minimum measurable cell concentration of 5 × 103 cells/ml on the multi-volume hemacytometer is twenty times lower. Additionally, the Multi-Volume Cell Counting model (cell concentration calculation with the slope value of cell number in multi-chambers) showed a wide measurement range (5 × 103 ~ 1 × 106 cells/ml) while reducing total cell counting numbers by 62.5% compared to a large volume (0.8 µl-chamber) hemacytometer. |
format |
article |
author |
Ravangnam Thunyaporn Il Doh Dong Woo Lee |
author_facet |
Ravangnam Thunyaporn Il Doh Dong Woo Lee |
author_sort |
Ravangnam Thunyaporn |
title |
Multi-volume hemacytometer |
title_short |
Multi-volume hemacytometer |
title_full |
Multi-volume hemacytometer |
title_fullStr |
Multi-volume hemacytometer |
title_full_unstemmed |
Multi-volume hemacytometer |
title_sort |
multi-volume hemacytometer |
publisher |
Nature Portfolio |
publishDate |
2021 |
url |
https://doaj.org/article/79d980e82a23455381918ede650b3f3e |
work_keys_str_mv |
AT ravangnamthunyaporn multivolumehemacytometer AT ildoh multivolumehemacytometer AT dongwoolee multivolumehemacytometer |
_version_ |
1718377870185725952 |