Estimation of postmortem interval by vitreous potassium evaluation with a novel fluorescence aptasensor

Abstract Estimation of postmortem interval (PMI) is a central role in medico-legal identification. Analysis of vitreous potassium ions (K+) concentration is frequently used by forensic workers to estimate PMI. This paper describes interdisciplinary research to introduce fluorescence sensing techniqu...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Yanjun Ding, Xingmei Li, Yadong Guo, Weicheng Duan, Jiang Ling, Lagabaiyla Zha, Jie Yan, Ying Zou, Jifeng Cai
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2017
Materias:
R
Q
Acceso en línea:https://doaj.org/article/7a9b2fa0405f40c68230aa5d37702f71
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:7a9b2fa0405f40c68230aa5d37702f71
record_format dspace
spelling oai:doaj.org-article:7a9b2fa0405f40c68230aa5d37702f712021-12-02T11:41:19ZEstimation of postmortem interval by vitreous potassium evaluation with a novel fluorescence aptasensor10.1038/s41598-017-02027-12045-2322https://doaj.org/article/7a9b2fa0405f40c68230aa5d37702f712017-05-01T00:00:00Zhttps://doi.org/10.1038/s41598-017-02027-1https://doaj.org/toc/2045-2322Abstract Estimation of postmortem interval (PMI) is a central role in medico-legal identification. Analysis of vitreous potassium ions (K+) concentration is frequently used by forensic workers to estimate PMI. This paper describes interdisciplinary research to introduce fluorescence sensing techniques into forensic medicine. On the basis of silver nanoclusters (AgNCs) probe stabilized by DNA, a simple and highly sensitive fluorescence aptasensor has been proposed to selectively detect K+ ions. The linear range for K+ ions was found to be 0.1 nM-1 mM, with limit of detection of 0.06 nM. Moreover, 63 vitreous humour cases within 36 h after death were further studied to verify the utility of K+ ions in estimating the PMI. By the fluorescence aptasensor method, a new formula was built to determine the postmortem interval based on K+ ions concentration: PMI(h) = −0.55 + 1.66 × CK +(r = 0.791). And the real significance of this research was demonstrated by additional 6 cases with known PMIs. In comparison with the conventional method, the presented aptasensor strategy is cost-effective and easy in measuring vitreous K+, which may be potentially a better way for estimation of PMI in medico-legal practice.Yanjun DingXingmei LiYadong GuoWeicheng DuanJiang LingLagabaiyla ZhaJie YanYing ZouJifeng CaiNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 7, Iss 1, Pp 1-9 (2017)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Yanjun Ding
Xingmei Li
Yadong Guo
Weicheng Duan
Jiang Ling
Lagabaiyla Zha
Jie Yan
Ying Zou
Jifeng Cai
Estimation of postmortem interval by vitreous potassium evaluation with a novel fluorescence aptasensor
description Abstract Estimation of postmortem interval (PMI) is a central role in medico-legal identification. Analysis of vitreous potassium ions (K+) concentration is frequently used by forensic workers to estimate PMI. This paper describes interdisciplinary research to introduce fluorescence sensing techniques into forensic medicine. On the basis of silver nanoclusters (AgNCs) probe stabilized by DNA, a simple and highly sensitive fluorescence aptasensor has been proposed to selectively detect K+ ions. The linear range for K+ ions was found to be 0.1 nM-1 mM, with limit of detection of 0.06 nM. Moreover, 63 vitreous humour cases within 36 h after death were further studied to verify the utility of K+ ions in estimating the PMI. By the fluorescence aptasensor method, a new formula was built to determine the postmortem interval based on K+ ions concentration: PMI(h) = −0.55 + 1.66 × CK +(r = 0.791). And the real significance of this research was demonstrated by additional 6 cases with known PMIs. In comparison with the conventional method, the presented aptasensor strategy is cost-effective and easy in measuring vitreous K+, which may be potentially a better way for estimation of PMI in medico-legal practice.
format article
author Yanjun Ding
Xingmei Li
Yadong Guo
Weicheng Duan
Jiang Ling
Lagabaiyla Zha
Jie Yan
Ying Zou
Jifeng Cai
author_facet Yanjun Ding
Xingmei Li
Yadong Guo
Weicheng Duan
Jiang Ling
Lagabaiyla Zha
Jie Yan
Ying Zou
Jifeng Cai
author_sort Yanjun Ding
title Estimation of postmortem interval by vitreous potassium evaluation with a novel fluorescence aptasensor
title_short Estimation of postmortem interval by vitreous potassium evaluation with a novel fluorescence aptasensor
title_full Estimation of postmortem interval by vitreous potassium evaluation with a novel fluorescence aptasensor
title_fullStr Estimation of postmortem interval by vitreous potassium evaluation with a novel fluorescence aptasensor
title_full_unstemmed Estimation of postmortem interval by vitreous potassium evaluation with a novel fluorescence aptasensor
title_sort estimation of postmortem interval by vitreous potassium evaluation with a novel fluorescence aptasensor
publisher Nature Portfolio
publishDate 2017
url https://doaj.org/article/7a9b2fa0405f40c68230aa5d37702f71
work_keys_str_mv AT yanjunding estimationofpostmortemintervalbyvitreouspotassiumevaluationwithanovelfluorescenceaptasensor
AT xingmeili estimationofpostmortemintervalbyvitreouspotassiumevaluationwithanovelfluorescenceaptasensor
AT yadongguo estimationofpostmortemintervalbyvitreouspotassiumevaluationwithanovelfluorescenceaptasensor
AT weichengduan estimationofpostmortemintervalbyvitreouspotassiumevaluationwithanovelfluorescenceaptasensor
AT jiangling estimationofpostmortemintervalbyvitreouspotassiumevaluationwithanovelfluorescenceaptasensor
AT lagabaiylazha estimationofpostmortemintervalbyvitreouspotassiumevaluationwithanovelfluorescenceaptasensor
AT jieyan estimationofpostmortemintervalbyvitreouspotassiumevaluationwithanovelfluorescenceaptasensor
AT yingzou estimationofpostmortemintervalbyvitreouspotassiumevaluationwithanovelfluorescenceaptasensor
AT jifengcai estimationofpostmortemintervalbyvitreouspotassiumevaluationwithanovelfluorescenceaptasensor
_version_ 1718395406127202304