Variability of total column ozone content measured at Chisinau site, Republic of Moldov

Results of the total column ozone measurements at the ground-based solar radiation monitoring station in Chisinau, Moldova are presented. Column ozone content was derived from the ratios of direct solar ultraviolet radiances measured at 3 discrete wavelengths 305-, 312-, 320-nm within UV-B range...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autor principal: Aculinin, Alexandr
Formato: article
Lenguaje:EN
Publicado: D.Ghitu Institute of Electronic Engineering and Nanotechnologies 2006
Materias:
Acceso en línea:https://doaj.org/article/7ab107c523c844c286fc3219a0bab86c
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:7ab107c523c844c286fc3219a0bab86c
record_format dspace
spelling oai:doaj.org-article:7ab107c523c844c286fc3219a0bab86c2021-11-21T12:09:56ZVariability of total column ozone content measured at Chisinau site, Republic of Moldov 2537-63651810-648Xhttps://doaj.org/article/7ab107c523c844c286fc3219a0bab86c2006-04-01T00:00:00Zhttps://mjps.nanotech.md/archive/2006/article/3495https://doaj.org/toc/1810-648Xhttps://doaj.org/toc/2537-6365Results of the total column ozone measurements at the ground-based solar radiation monitoring station in Chisinau, Moldova are presented. Column ozone content was derived from the ratios of direct solar ultraviolet radiances measured at 3 discrete wavelengths 305-, 312-, 320-nm within UV-B range. Ozone measurements are regularly carried out with hand- held MICROTOPS II Ozonometer, Solar Light Co. Monthly averages of total column ozone content measured with MICROTOPS II ozonometer at the Chisinau site are in close agreement with those retrieved from the multi-year (1957-2005) measurements carried out at number of ground stations and at the satellite platforms Nimbus -7, Meteor-3, and Earth Probe equipped with the Total Ozone Mapping Spectrometer (TOMS). Total ozone content reveals distinctive seasonal variation at the Chisinau site with maximum and minimum values in spring and fall, respectively. Climatic mean value of total column ozone content derived from TOMS data at the Chisinau site amounts to 334.7 DU. 1. Introduction Aculinin, AlexandrD.Ghitu Institute of Electronic Engineering and NanotechnologiesarticlePhysicsQC1-999ElectronicsTK7800-8360ENMoldavian Journal of the Physical Sciences, Vol 5, Iss 2, Pp 240-248 (2006)
institution DOAJ
collection DOAJ
language EN
topic Physics
QC1-999
Electronics
TK7800-8360
spellingShingle Physics
QC1-999
Electronics
TK7800-8360
Aculinin, Alexandr
Variability of total column ozone content measured at Chisinau site, Republic of Moldov
description Results of the total column ozone measurements at the ground-based solar radiation monitoring station in Chisinau, Moldova are presented. Column ozone content was derived from the ratios of direct solar ultraviolet radiances measured at 3 discrete wavelengths 305-, 312-, 320-nm within UV-B range. Ozone measurements are regularly carried out with hand- held MICROTOPS II Ozonometer, Solar Light Co. Monthly averages of total column ozone content measured with MICROTOPS II ozonometer at the Chisinau site are in close agreement with those retrieved from the multi-year (1957-2005) measurements carried out at number of ground stations and at the satellite platforms Nimbus -7, Meteor-3, and Earth Probe equipped with the Total Ozone Mapping Spectrometer (TOMS). Total ozone content reveals distinctive seasonal variation at the Chisinau site with maximum and minimum values in spring and fall, respectively. Climatic mean value of total column ozone content derived from TOMS data at the Chisinau site amounts to 334.7 DU. 1. Introduction
format article
author Aculinin, Alexandr
author_facet Aculinin, Alexandr
author_sort Aculinin, Alexandr
title Variability of total column ozone content measured at Chisinau site, Republic of Moldov
title_short Variability of total column ozone content measured at Chisinau site, Republic of Moldov
title_full Variability of total column ozone content measured at Chisinau site, Republic of Moldov
title_fullStr Variability of total column ozone content measured at Chisinau site, Republic of Moldov
title_full_unstemmed Variability of total column ozone content measured at Chisinau site, Republic of Moldov
title_sort variability of total column ozone content measured at chisinau site, republic of moldov
publisher D.Ghitu Institute of Electronic Engineering and Nanotechnologies
publishDate 2006
url https://doaj.org/article/7ab107c523c844c286fc3219a0bab86c
work_keys_str_mv AT aculininalexandr variabilityoftotalcolumnozonecontentmeasuredatchisinausiterepublicofmoldov
_version_ 1718419194662354944