Variability of total column ozone content measured at Chisinau site, Republic of Moldov
Results of the total column ozone measurements at the ground-based solar radiation monitoring station in Chisinau, Moldova are presented. Column ozone content was derived from the ratios of direct solar ultraviolet radiances measured at 3 discrete wavelengths 305-, 312-, 320-nm within UV-B range...
Guardado en:
Autor principal: | |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
D.Ghitu Institute of Electronic Engineering and Nanotechnologies
2006
|
Materias: | |
Acceso en línea: | https://doaj.org/article/7ab107c523c844c286fc3219a0bab86c |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:7ab107c523c844c286fc3219a0bab86c |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:7ab107c523c844c286fc3219a0bab86c2021-11-21T12:09:56ZVariability of total column ozone content measured at Chisinau site, Republic of Moldov 2537-63651810-648Xhttps://doaj.org/article/7ab107c523c844c286fc3219a0bab86c2006-04-01T00:00:00Zhttps://mjps.nanotech.md/archive/2006/article/3495https://doaj.org/toc/1810-648Xhttps://doaj.org/toc/2537-6365Results of the total column ozone measurements at the ground-based solar radiation monitoring station in Chisinau, Moldova are presented. Column ozone content was derived from the ratios of direct solar ultraviolet radiances measured at 3 discrete wavelengths 305-, 312-, 320-nm within UV-B range. Ozone measurements are regularly carried out with hand- held MICROTOPS II Ozonometer, Solar Light Co. Monthly averages of total column ozone content measured with MICROTOPS II ozonometer at the Chisinau site are in close agreement with those retrieved from the multi-year (1957-2005) measurements carried out at number of ground stations and at the satellite platforms Nimbus -7, Meteor-3, and Earth Probe equipped with the Total Ozone Mapping Spectrometer (TOMS). Total ozone content reveals distinctive seasonal variation at the Chisinau site with maximum and minimum values in spring and fall, respectively. Climatic mean value of total column ozone content derived from TOMS data at the Chisinau site amounts to 334.7 DU. 1. Introduction Aculinin, AlexandrD.Ghitu Institute of Electronic Engineering and NanotechnologiesarticlePhysicsQC1-999ElectronicsTK7800-8360ENMoldavian Journal of the Physical Sciences, Vol 5, Iss 2, Pp 240-248 (2006) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Physics QC1-999 Electronics TK7800-8360 |
spellingShingle |
Physics QC1-999 Electronics TK7800-8360 Aculinin, Alexandr Variability of total column ozone content measured at Chisinau site, Republic of Moldov |
description |
Results of the total column ozone measurements at the ground-based solar radiation
monitoring station in Chisinau, Moldova are presented. Column ozone content was derived
from the ratios of direct solar ultraviolet radiances measured at 3 discrete wavelengths 305-,
312-, 320-nm within UV-B range. Ozone measurements are regularly carried out with hand-
held MICROTOPS II Ozonometer, Solar Light Co. Monthly averages of total column ozone
content measured with MICROTOPS II ozonometer at the Chisinau site are in close agreement with those retrieved from the multi-year (1957-2005) measurements carried out at number of ground stations and at the satellite platforms Nimbus -7, Meteor-3, and Earth Probe
equipped with the Total Ozone Mapping Spectrometer (TOMS). Total ozone content reveals
distinctive seasonal variation at the Chisinau site with maximum and minimum values in
spring and fall, respectively. Climatic mean value of total column ozone content derived from
TOMS data at the Chisinau site amounts to 334.7 DU.
1. Introduction |
format |
article |
author |
Aculinin, Alexandr |
author_facet |
Aculinin, Alexandr |
author_sort |
Aculinin, Alexandr |
title |
Variability of total column ozone content measured at Chisinau site, Republic of Moldov |
title_short |
Variability of total column ozone content measured at Chisinau site, Republic of Moldov |
title_full |
Variability of total column ozone content measured at Chisinau site, Republic of Moldov |
title_fullStr |
Variability of total column ozone content measured at Chisinau site, Republic of Moldov |
title_full_unstemmed |
Variability of total column ozone content measured at Chisinau site, Republic of Moldov |
title_sort |
variability of total column ozone content measured at chisinau site, republic of moldov |
publisher |
D.Ghitu Institute of Electronic Engineering and Nanotechnologies |
publishDate |
2006 |
url |
https://doaj.org/article/7ab107c523c844c286fc3219a0bab86c |
work_keys_str_mv |
AT aculininalexandr variabilityoftotalcolumnozonecontentmeasuredatchisinausiterepublicofmoldov |
_version_ |
1718419194662354944 |