Assessment of planning reproducibility in three-dimensional field-in-field radiotherapy technique for breast cancer: impact of surgery-simulation interval

Abstract The three-dimensional field-in-field (3-D FIF) technique for radiotherapy is an advanced, state-of-the-art method that uses multileaf collimators to generate a homogeneous and conformal dose distribution via segmental subfields. The purpose of this study is to evaluate the dosimetric reprod...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Dong Soo Lee, Young Kyu Lee, Young Nam Kang, Yong Gyun Won, Seung Hwan Park, Yong Seok Kim, Jeong Soo Kim, Hye Sung Won
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/7acddb9497aa4790843f7d3ceff90ddb
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:7acddb9497aa4790843f7d3ceff90ddb
record_format dspace
spelling oai:doaj.org-article:7acddb9497aa4790843f7d3ceff90ddb2021-12-02T14:12:10ZAssessment of planning reproducibility in three-dimensional field-in-field radiotherapy technique for breast cancer: impact of surgery-simulation interval10.1038/s41598-020-78666-82045-2322https://doaj.org/article/7acddb9497aa4790843f7d3ceff90ddb2021-01-01T00:00:00Zhttps://doi.org/10.1038/s41598-020-78666-8https://doaj.org/toc/2045-2322Abstract The three-dimensional field-in-field (3-D FIF) technique for radiotherapy is an advanced, state-of-the-art method that uses multileaf collimators to generate a homogeneous and conformal dose distribution via segmental subfields. The purpose of this study is to evaluate the dosimetric reproducibility of 3-D FIF plans using the original simulation computed tomography (iCT) scans and re-simulation CT (rCT) scans for whole breast irradiation (WBI) schedule. This study enrolled a total of 34 patients. The study population underwent iCT scans for standard WBI and took rCT scans after 45 Gy of WBI for cone down boost plans. The dosimetric parameters (V105%, V103%, V100%, V98%, V95%, V90%, V50%), plan quality indices (conformity index, homogeneity index) and clinical parameters (isocenter-breast axis, isocenter-lung axis, soft tissue volumes within radiation field, lung volumes within radiation field) were assessed. The median time interval from surgery to iCT was 33 days and from iCT to rCT was 35 days. All dosimetric parameters exhibited statistically significant differences between iCT and rCT among cohorts with a surgery-iCT interval of < 60 days. Homogeneity index showed a statistically significant increase from iCT to rCT among all cohorts. Soft tissue volumes (p = 0.001) and isocenter-breast axis (p = 0.032) exhibited statistically significant differences among cohorts with surgery-iCT interval < 60 days. Regarding the reproducibility of the 3-D FIF WBI plans, significant changes were observed in dosimetric and clinical factors, particularly in study cohorts with a surgery-simulation interval < 60 days. The main contributing factor of these transitions seemed to be the changes in volume of the soft tissue within the WBI field. Further confirmative studies are necessary to determine the most suitable timing and technique for WBI.Dong Soo LeeYoung Kyu LeeYoung Nam KangYong Gyun WonSeung Hwan ParkYong Seok KimJeong Soo KimHye Sung WonNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-9 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Dong Soo Lee
Young Kyu Lee
Young Nam Kang
Yong Gyun Won
Seung Hwan Park
Yong Seok Kim
Jeong Soo Kim
Hye Sung Won
Assessment of planning reproducibility in three-dimensional field-in-field radiotherapy technique for breast cancer: impact of surgery-simulation interval
description Abstract The three-dimensional field-in-field (3-D FIF) technique for radiotherapy is an advanced, state-of-the-art method that uses multileaf collimators to generate a homogeneous and conformal dose distribution via segmental subfields. The purpose of this study is to evaluate the dosimetric reproducibility of 3-D FIF plans using the original simulation computed tomography (iCT) scans and re-simulation CT (rCT) scans for whole breast irradiation (WBI) schedule. This study enrolled a total of 34 patients. The study population underwent iCT scans for standard WBI and took rCT scans after 45 Gy of WBI for cone down boost plans. The dosimetric parameters (V105%, V103%, V100%, V98%, V95%, V90%, V50%), plan quality indices (conformity index, homogeneity index) and clinical parameters (isocenter-breast axis, isocenter-lung axis, soft tissue volumes within radiation field, lung volumes within radiation field) were assessed. The median time interval from surgery to iCT was 33 days and from iCT to rCT was 35 days. All dosimetric parameters exhibited statistically significant differences between iCT and rCT among cohorts with a surgery-iCT interval of < 60 days. Homogeneity index showed a statistically significant increase from iCT to rCT among all cohorts. Soft tissue volumes (p = 0.001) and isocenter-breast axis (p = 0.032) exhibited statistically significant differences among cohorts with surgery-iCT interval < 60 days. Regarding the reproducibility of the 3-D FIF WBI plans, significant changes were observed in dosimetric and clinical factors, particularly in study cohorts with a surgery-simulation interval < 60 days. The main contributing factor of these transitions seemed to be the changes in volume of the soft tissue within the WBI field. Further confirmative studies are necessary to determine the most suitable timing and technique for WBI.
format article
author Dong Soo Lee
Young Kyu Lee
Young Nam Kang
Yong Gyun Won
Seung Hwan Park
Yong Seok Kim
Jeong Soo Kim
Hye Sung Won
author_facet Dong Soo Lee
Young Kyu Lee
Young Nam Kang
Yong Gyun Won
Seung Hwan Park
Yong Seok Kim
Jeong Soo Kim
Hye Sung Won
author_sort Dong Soo Lee
title Assessment of planning reproducibility in three-dimensional field-in-field radiotherapy technique for breast cancer: impact of surgery-simulation interval
title_short Assessment of planning reproducibility in three-dimensional field-in-field radiotherapy technique for breast cancer: impact of surgery-simulation interval
title_full Assessment of planning reproducibility in three-dimensional field-in-field radiotherapy technique for breast cancer: impact of surgery-simulation interval
title_fullStr Assessment of planning reproducibility in three-dimensional field-in-field radiotherapy technique for breast cancer: impact of surgery-simulation interval
title_full_unstemmed Assessment of planning reproducibility in three-dimensional field-in-field radiotherapy technique for breast cancer: impact of surgery-simulation interval
title_sort assessment of planning reproducibility in three-dimensional field-in-field radiotherapy technique for breast cancer: impact of surgery-simulation interval
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/7acddb9497aa4790843f7d3ceff90ddb
work_keys_str_mv AT dongsoolee assessmentofplanningreproducibilityinthreedimensionalfieldinfieldradiotherapytechniqueforbreastcancerimpactofsurgerysimulationinterval
AT youngkyulee assessmentofplanningreproducibilityinthreedimensionalfieldinfieldradiotherapytechniqueforbreastcancerimpactofsurgerysimulationinterval
AT youngnamkang assessmentofplanningreproducibilityinthreedimensionalfieldinfieldradiotherapytechniqueforbreastcancerimpactofsurgerysimulationinterval
AT yonggyunwon assessmentofplanningreproducibilityinthreedimensionalfieldinfieldradiotherapytechniqueforbreastcancerimpactofsurgerysimulationinterval
AT seunghwanpark assessmentofplanningreproducibilityinthreedimensionalfieldinfieldradiotherapytechniqueforbreastcancerimpactofsurgerysimulationinterval
AT yongseokkim assessmentofplanningreproducibilityinthreedimensionalfieldinfieldradiotherapytechniqueforbreastcancerimpactofsurgerysimulationinterval
AT jeongsookim assessmentofplanningreproducibilityinthreedimensionalfieldinfieldradiotherapytechniqueforbreastcancerimpactofsurgerysimulationinterval
AT hyesungwon assessmentofplanningreproducibilityinthreedimensionalfieldinfieldradiotherapytechniqueforbreastcancerimpactofsurgerysimulationinterval
_version_ 1718391792925147136