Risk Factors and Temporal Trends of Complications Associated With Transvenous Implantable Cardiac Defibrillator Leads
BackgroundThe transvenous implantable cardioverter‐defibrillator (ICD) lead is the most common source of complications in a traditional ICD system. This investigation aims to determine the incidence, predictors, and costs associated with these complications using a large insurance database. Methods...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Wiley
2018
|
Materias: | |
Acceso en línea: | https://doaj.org/article/7bbcb9aa4a414a858331476b62e1e515 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:7bbcb9aa4a414a858331476b62e1e515 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:7bbcb9aa4a414a858331476b62e1e5152021-11-12T17:02:04ZRisk Factors and Temporal Trends of Complications Associated With Transvenous Implantable Cardiac Defibrillator Leads10.1161/JAHA.117.0076912047-9980https://doaj.org/article/7bbcb9aa4a414a858331476b62e1e5152018-05-01T00:00:00Zhttps://www.ahajournals.org/doi/10.1161/JAHA.117.007691https://doaj.org/toc/2047-9980BackgroundThe transvenous implantable cardioverter‐defibrillator (ICD) lead is the most common source of complications in a traditional ICD system. This investigation aims to determine the incidence, predictors, and costs associated with these complications using a large insurance database. Methods and ResultsData from the OptumLabs™ Data Warehouse, which include diagnosis, physician and procedure codes, and claims from patient hospitalizations, were analyzed. Patients with a de novo ICD or cardiac resynchronization therapy defibrillator implanted from January 1, 2003, through June 30, 2015, were included; those who did not have continuous coverage beginning 1 year before implantation were excluded, resulting in 40 837 patients followed up over an average of 2.3±2.1 years. Patients were followed up until they had the procedure or their last active date in the database. Of 20 580 device procedures, 2165 (5.3%) and 771 (1.9%) had mechanical and infectious complications, respectively. The 5‐year rate of freedom from mechanical complication was 92.0% and 89.3% for ICDs and cardiac resynchronization therapy defibrillators, respectively. Infectious complications were more likely in patients with a history of atrial fibrillation, diabetes mellitus, and renal disease, and the risk increased with subsequent device procedures. Younger age, female sex, lack of comorbidities, and implantations between 2003 and 2008 were associated with more mechanical complications. ConclusionsIncidence of mechanical and infectious complications of transvenous ICD leads over long‐term follow‐up is much higher in the real world than in clinical studies. In our study cohort, 1 of 4 transvenous ICD leads had mechanical complications when followed up to 10 years. The high rate of reintervention leads to additional complications.Jayanthi N. KoneruPaul W. JonesEric F. HammillNicholas WoldKenneth A. EllenbogenWileyarticlecomplicationimplantable cardioverter‐defibrillatorinfectionDiseases of the circulatory (Cardiovascular) systemRC666-701ENJournal of the American Heart Association: Cardiovascular and Cerebrovascular Disease, Vol 7, Iss 10 (2018) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
complication implantable cardioverter‐defibrillator infection Diseases of the circulatory (Cardiovascular) system RC666-701 |
spellingShingle |
complication implantable cardioverter‐defibrillator infection Diseases of the circulatory (Cardiovascular) system RC666-701 Jayanthi N. Koneru Paul W. Jones Eric F. Hammill Nicholas Wold Kenneth A. Ellenbogen Risk Factors and Temporal Trends of Complications Associated With Transvenous Implantable Cardiac Defibrillator Leads |
description |
BackgroundThe transvenous implantable cardioverter‐defibrillator (ICD) lead is the most common source of complications in a traditional ICD system. This investigation aims to determine the incidence, predictors, and costs associated with these complications using a large insurance database. Methods and ResultsData from the OptumLabs™ Data Warehouse, which include diagnosis, physician and procedure codes, and claims from patient hospitalizations, were analyzed. Patients with a de novo ICD or cardiac resynchronization therapy defibrillator implanted from January 1, 2003, through June 30, 2015, were included; those who did not have continuous coverage beginning 1 year before implantation were excluded, resulting in 40 837 patients followed up over an average of 2.3±2.1 years. Patients were followed up until they had the procedure or their last active date in the database. Of 20 580 device procedures, 2165 (5.3%) and 771 (1.9%) had mechanical and infectious complications, respectively. The 5‐year rate of freedom from mechanical complication was 92.0% and 89.3% for ICDs and cardiac resynchronization therapy defibrillators, respectively. Infectious complications were more likely in patients with a history of atrial fibrillation, diabetes mellitus, and renal disease, and the risk increased with subsequent device procedures. Younger age, female sex, lack of comorbidities, and implantations between 2003 and 2008 were associated with more mechanical complications. ConclusionsIncidence of mechanical and infectious complications of transvenous ICD leads over long‐term follow‐up is much higher in the real world than in clinical studies. In our study cohort, 1 of 4 transvenous ICD leads had mechanical complications when followed up to 10 years. The high rate of reintervention leads to additional complications. |
format |
article |
author |
Jayanthi N. Koneru Paul W. Jones Eric F. Hammill Nicholas Wold Kenneth A. Ellenbogen |
author_facet |
Jayanthi N. Koneru Paul W. Jones Eric F. Hammill Nicholas Wold Kenneth A. Ellenbogen |
author_sort |
Jayanthi N. Koneru |
title |
Risk Factors and Temporal Trends of Complications Associated With Transvenous Implantable Cardiac Defibrillator Leads |
title_short |
Risk Factors and Temporal Trends of Complications Associated With Transvenous Implantable Cardiac Defibrillator Leads |
title_full |
Risk Factors and Temporal Trends of Complications Associated With Transvenous Implantable Cardiac Defibrillator Leads |
title_fullStr |
Risk Factors and Temporal Trends of Complications Associated With Transvenous Implantable Cardiac Defibrillator Leads |
title_full_unstemmed |
Risk Factors and Temporal Trends of Complications Associated With Transvenous Implantable Cardiac Defibrillator Leads |
title_sort |
risk factors and temporal trends of complications associated with transvenous implantable cardiac defibrillator leads |
publisher |
Wiley |
publishDate |
2018 |
url |
https://doaj.org/article/7bbcb9aa4a414a858331476b62e1e515 |
work_keys_str_mv |
AT jayanthinkoneru riskfactorsandtemporaltrendsofcomplicationsassociatedwithtransvenousimplantablecardiacdefibrillatorleads AT paulwjones riskfactorsandtemporaltrendsofcomplicationsassociatedwithtransvenousimplantablecardiacdefibrillatorleads AT ericfhammill riskfactorsandtemporaltrendsofcomplicationsassociatedwithtransvenousimplantablecardiacdefibrillatorleads AT nicholaswold riskfactorsandtemporaltrendsofcomplicationsassociatedwithtransvenousimplantablecardiacdefibrillatorleads AT kennethaellenbogen riskfactorsandtemporaltrendsofcomplicationsassociatedwithtransvenousimplantablecardiacdefibrillatorleads |
_version_ |
1718430326283304960 |