Comparison of two VHIT software programs in diagnostics of semicircular canals

Introduction The aim of this work was to assess SCC function in VHIT test, using both versions of VHIT ULMER. Material and methods The study was performed in 57 subjects aged 22–33 years (48 women and 9 men) without vertigo in anamnesis. Patients did not complain of any “vertigo” ailments or any ba...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Piotr Pietkiewicz, Jaroslaw Milonski, Marzena Bielinska, Jurek Olszewski
Formato: article
Lenguaje:EN
Publicado: Termedia Publishing House 2019
Materias:
R
Acceso en línea:https://doaj.org/article/7c1d568d05d3461d841f827cb58181ff
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:7c1d568d05d3461d841f827cb58181ff
record_format dspace
spelling oai:doaj.org-article:7c1d568d05d3461d841f827cb58181ff2021-12-02T16:59:25ZComparison of two VHIT software programs in diagnostics of semicircular canals1734-19221896-915110.5114/aoms.2017.66048https://doaj.org/article/7c1d568d05d3461d841f827cb58181ff2019-12-01T00:00:00Zhttps://www.archivesofmedicalscience.com/Comparison-of-two-VHIT-software-programs-in-diagnostics-of-semicircular-canals,67019,0,2.htmlhttps://doaj.org/toc/1734-1922https://doaj.org/toc/1896-9151Introduction The aim of this work was to assess SCC function in VHIT test, using both versions of VHIT ULMER. Material and methods The study was performed in 57 subjects aged 22–33 years (48 women and 9 men) without vertigo in anamnesis. Patients did not complain of any “vertigo” ailments or any balance disorder incidents in the past. All tests using either VHIT I or VHIT II were performed by the same person. The function of lateral SCC in VHIT ULMER II was examined similarly like in VHIT ULMER I. In both methods was used the same sensitivity threshold parameters for horizontal and vertical accelerations (horizontal – 2500, vertical – 1600). Each of these sequences enables a parameter, called represented GAIN, to be calculated in form of a point on the canalogram. Results GAIN represents the deviation of the gaze in comparison to the deviation of the head between the first (t – 0 ms) and the fourth image (t = 120 ms). The calculation formula is: GAIN (in %) =100 x DG/RH. DG is deviation of the gaze (“gaze velocity in space”) and RH is rotation of the head (“head velocity or impulse canal paresis”). Normal GAIN value ranges 1–40%. Conclusions The examination using VHIT ULMER II appears to be a more sensitive diagnostic method than VHIT ULMER I. Improved software with automated functions such as camera adjustments, examination surface arrangement, of VHIT ULMER II, enables technician to shorten the time of examination, simultaneously providing a range of new information about the condition of oculo-vestibular system.Piotr PietkiewiczJaroslaw MilonskiMarzena BielinskaJurek OlszewskiTermedia Publishing Housearticletwo vhit software programssemicircular canals functionvertigo diagnosticssemicircular canal diagnosticsMedicineRENArchives of Medical Science, Vol 16, Iss 1, Pp 124-128 (2019)
institution DOAJ
collection DOAJ
language EN
topic two vhit software programs
semicircular canals function
vertigo diagnostics
semicircular canal diagnostics
Medicine
R
spellingShingle two vhit software programs
semicircular canals function
vertigo diagnostics
semicircular canal diagnostics
Medicine
R
Piotr Pietkiewicz
Jaroslaw Milonski
Marzena Bielinska
Jurek Olszewski
Comparison of two VHIT software programs in diagnostics of semicircular canals
description Introduction The aim of this work was to assess SCC function in VHIT test, using both versions of VHIT ULMER. Material and methods The study was performed in 57 subjects aged 22–33 years (48 women and 9 men) without vertigo in anamnesis. Patients did not complain of any “vertigo” ailments or any balance disorder incidents in the past. All tests using either VHIT I or VHIT II were performed by the same person. The function of lateral SCC in VHIT ULMER II was examined similarly like in VHIT ULMER I. In both methods was used the same sensitivity threshold parameters for horizontal and vertical accelerations (horizontal – 2500, vertical – 1600). Each of these sequences enables a parameter, called represented GAIN, to be calculated in form of a point on the canalogram. Results GAIN represents the deviation of the gaze in comparison to the deviation of the head between the first (t – 0 ms) and the fourth image (t = 120 ms). The calculation formula is: GAIN (in %) =100 x DG/RH. DG is deviation of the gaze (“gaze velocity in space”) and RH is rotation of the head (“head velocity or impulse canal paresis”). Normal GAIN value ranges 1–40%. Conclusions The examination using VHIT ULMER II appears to be a more sensitive diagnostic method than VHIT ULMER I. Improved software with automated functions such as camera adjustments, examination surface arrangement, of VHIT ULMER II, enables technician to shorten the time of examination, simultaneously providing a range of new information about the condition of oculo-vestibular system.
format article
author Piotr Pietkiewicz
Jaroslaw Milonski
Marzena Bielinska
Jurek Olszewski
author_facet Piotr Pietkiewicz
Jaroslaw Milonski
Marzena Bielinska
Jurek Olszewski
author_sort Piotr Pietkiewicz
title Comparison of two VHIT software programs in diagnostics of semicircular canals
title_short Comparison of two VHIT software programs in diagnostics of semicircular canals
title_full Comparison of two VHIT software programs in diagnostics of semicircular canals
title_fullStr Comparison of two VHIT software programs in diagnostics of semicircular canals
title_full_unstemmed Comparison of two VHIT software programs in diagnostics of semicircular canals
title_sort comparison of two vhit software programs in diagnostics of semicircular canals
publisher Termedia Publishing House
publishDate 2019
url https://doaj.org/article/7c1d568d05d3461d841f827cb58181ff
work_keys_str_mv AT piotrpietkiewicz comparisonoftwovhitsoftwareprogramsindiagnosticsofsemicircularcanals
AT jaroslawmilonski comparisonoftwovhitsoftwareprogramsindiagnosticsofsemicircularcanals
AT marzenabielinska comparisonoftwovhitsoftwareprogramsindiagnosticsofsemicircularcanals
AT jurekolszewski comparisonoftwovhitsoftwareprogramsindiagnosticsofsemicircularcanals
_version_ 1718382273806467072