Immediate Restoration of Single-Piece Zirconia Implants: A Prospective Case Series—Long-Term Results after 11 Years of Clinical Function
Objectives: The aim of this prospective case series was to evaluate single-piece zirconia implants restored with lithium disilicate CAD/CAM crowns through a long-term follow-up. Methods: In this trial, 20 one-piece zirconia implants were placed in 20 patients. Implants were restored (i) immediately...
Guardado en:
Autores principales: | , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
MDPI AG
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/7c87480cc25248929e4c3b2f10301f60 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:7c87480cc25248929e4c3b2f10301f60 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:7c87480cc25248929e4c3b2f10301f602021-11-25T18:13:10ZImmediate Restoration of Single-Piece Zirconia Implants: A Prospective Case Series—Long-Term Results after 11 Years of Clinical Function10.3390/ma142267381996-1944https://doaj.org/article/7c87480cc25248929e4c3b2f10301f602021-11-01T00:00:00Zhttps://www.mdpi.com/1996-1944/14/22/6738https://doaj.org/toc/1996-1944Objectives: The aim of this prospective case series was to evaluate single-piece zirconia implants restored with lithium disilicate CAD/CAM crowns through a long-term follow-up. Methods: In this trial, 20 one-piece zirconia implants were placed in 20 patients. Implants were restored (i) immediately with lithium disilicate CAD/CAM provisionals, and (ii) permanently four months after surgery. Patients were followed for 11 years. Clinical parameters and radiological measurements of the zirconia implants were assessed. For the statistical analysis, paired <i>t</i>-test was applied. Results: Four implants were counted as implant failure due to the loss of implant stability, resulting in a Kaplan–Meier survival rate of 80% up to 11 years. The mean bleeding on probing values were 19.1% (SD ± 13.1) and 18.2% (SD ± 17.6) 96 and 11 years after implant placement, respectively. The plaque index revealed a significant decrease over time (<i>p</i> < 0.001) with a value between 25.9% (SD ± 5.7) and 12.6% (SD ± 10.0) at baseline and 11-years follow-up respectively. The marginal bone level revealed a significant decrease 4, 8, and 11 years after implant insertion (<i>p</i> = 0.001, <i>p</i> = 0.019, and <i>p</i> = 0.027, respectively). Conclusions: Immediately loaded zirconia single-piece implants showed a suitable success rate in clinical and radiographic outcomes.Elisabeth SteyerValentin HerberMartin KollerDániel VéghKhaled MukaddamNorbert JakseMichael PayerMDPI AGarticleCAD/CAMimmediate loadingradiographic bone levelzirconia implantsTechnologyTElectrical engineering. Electronics. Nuclear engineeringTK1-9971Engineering (General). Civil engineering (General)TA1-2040MicroscopyQH201-278.5Descriptive and experimental mechanicsQC120-168.85ENMaterials, Vol 14, Iss 6738, p 6738 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
CAD/CAM immediate loading radiographic bone level zirconia implants Technology T Electrical engineering. Electronics. Nuclear engineering TK1-9971 Engineering (General). Civil engineering (General) TA1-2040 Microscopy QH201-278.5 Descriptive and experimental mechanics QC120-168.85 |
spellingShingle |
CAD/CAM immediate loading radiographic bone level zirconia implants Technology T Electrical engineering. Electronics. Nuclear engineering TK1-9971 Engineering (General). Civil engineering (General) TA1-2040 Microscopy QH201-278.5 Descriptive and experimental mechanics QC120-168.85 Elisabeth Steyer Valentin Herber Martin Koller Dániel Végh Khaled Mukaddam Norbert Jakse Michael Payer Immediate Restoration of Single-Piece Zirconia Implants: A Prospective Case Series—Long-Term Results after 11 Years of Clinical Function |
description |
Objectives: The aim of this prospective case series was to evaluate single-piece zirconia implants restored with lithium disilicate CAD/CAM crowns through a long-term follow-up. Methods: In this trial, 20 one-piece zirconia implants were placed in 20 patients. Implants were restored (i) immediately with lithium disilicate CAD/CAM provisionals, and (ii) permanently four months after surgery. Patients were followed for 11 years. Clinical parameters and radiological measurements of the zirconia implants were assessed. For the statistical analysis, paired <i>t</i>-test was applied. Results: Four implants were counted as implant failure due to the loss of implant stability, resulting in a Kaplan–Meier survival rate of 80% up to 11 years. The mean bleeding on probing values were 19.1% (SD ± 13.1) and 18.2% (SD ± 17.6) 96 and 11 years after implant placement, respectively. The plaque index revealed a significant decrease over time (<i>p</i> < 0.001) with a value between 25.9% (SD ± 5.7) and 12.6% (SD ± 10.0) at baseline and 11-years follow-up respectively. The marginal bone level revealed a significant decrease 4, 8, and 11 years after implant insertion (<i>p</i> = 0.001, <i>p</i> = 0.019, and <i>p</i> = 0.027, respectively). Conclusions: Immediately loaded zirconia single-piece implants showed a suitable success rate in clinical and radiographic outcomes. |
format |
article |
author |
Elisabeth Steyer Valentin Herber Martin Koller Dániel Végh Khaled Mukaddam Norbert Jakse Michael Payer |
author_facet |
Elisabeth Steyer Valentin Herber Martin Koller Dániel Végh Khaled Mukaddam Norbert Jakse Michael Payer |
author_sort |
Elisabeth Steyer |
title |
Immediate Restoration of Single-Piece Zirconia Implants: A Prospective Case Series—Long-Term Results after 11 Years of Clinical Function |
title_short |
Immediate Restoration of Single-Piece Zirconia Implants: A Prospective Case Series—Long-Term Results after 11 Years of Clinical Function |
title_full |
Immediate Restoration of Single-Piece Zirconia Implants: A Prospective Case Series—Long-Term Results after 11 Years of Clinical Function |
title_fullStr |
Immediate Restoration of Single-Piece Zirconia Implants: A Prospective Case Series—Long-Term Results after 11 Years of Clinical Function |
title_full_unstemmed |
Immediate Restoration of Single-Piece Zirconia Implants: A Prospective Case Series—Long-Term Results after 11 Years of Clinical Function |
title_sort |
immediate restoration of single-piece zirconia implants: a prospective case series—long-term results after 11 years of clinical function |
publisher |
MDPI AG |
publishDate |
2021 |
url |
https://doaj.org/article/7c87480cc25248929e4c3b2f10301f60 |
work_keys_str_mv |
AT elisabethsteyer immediaterestorationofsinglepiecezirconiaimplantsaprospectivecaseserieslongtermresultsafter11yearsofclinicalfunction AT valentinherber immediaterestorationofsinglepiecezirconiaimplantsaprospectivecaseserieslongtermresultsafter11yearsofclinicalfunction AT martinkoller immediaterestorationofsinglepiecezirconiaimplantsaprospectivecaseserieslongtermresultsafter11yearsofclinicalfunction AT danielvegh immediaterestorationofsinglepiecezirconiaimplantsaprospectivecaseserieslongtermresultsafter11yearsofclinicalfunction AT khaledmukaddam immediaterestorationofsinglepiecezirconiaimplantsaprospectivecaseserieslongtermresultsafter11yearsofclinicalfunction AT norbertjakse immediaterestorationofsinglepiecezirconiaimplantsaprospectivecaseserieslongtermresultsafter11yearsofclinicalfunction AT michaelpayer immediaterestorationofsinglepiecezirconiaimplantsaprospectivecaseserieslongtermresultsafter11yearsofclinicalfunction |
_version_ |
1718411446000287744 |