Visual Outcomes, Visual Quality and Patient Satisfaction: Comparing a Blended Bifocal Approach to Bilateral Extended Depth of Focus Intraocular Lens Implantation

Matthew D Hammond,1 Richard Potvin2 1Swagel Wootton Eye Institute, Mesa, AZ, USA; 2Science in Vision, Akron, NY, USACorrespondence: Richard Potvin 6197 Dye Road, Akron, NY 14001, USATel +1 407-697-6008Email rick@scienceinvision.comPurpose: To compare visual outcomes, quality of vision and patient sa...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Hammond MD, Potvin R
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2019
Materias:
Acceso en línea:https://doaj.org/article/7c98ab7c3f204a6c8f35eb1b03b7d8cb
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:Matthew D Hammond,1 Richard Potvin2 1Swagel Wootton Eye Institute, Mesa, AZ, USA; 2Science in Vision, Akron, NY, USACorrespondence: Richard Potvin 6197 Dye Road, Akron, NY 14001, USATel +1 407-697-6008Email rick@scienceinvision.comPurpose: To compare visual outcomes, quality of vision and patient satisfaction between a blended apodized diffractive bifocal lens combination and bilateral implantation of an extended depth of focus intraocular lens (IOL).Patients and methods: Subjects implanted with either the blended bifocal (Blended) or bilateral extended depth of focus (EDOF) IOL combinations were examined 3 to 24 months after second eye surgery. The primary outcome measure was the patient’s best distance-corrected near visual acuity (VA) at 40cm. The secondary outcome measures were scores on the Quality of Vision Survey, the Catquest-9SF and the Visual Functioning Questionnaires, uncorrected binocular intermediate and near VA at 4–6m, 60cm and 40cm, the manifest refraction and the best-corrected monocular and binocular distance VA.Results: Twenty-five EDOF subjects and 23 blended subjects were analyzed. The uncorrected and best-distance corrected intermediate VA was statistically significantly better in the EDOF group (p < 0.05); no other significant differences were noted at distance or near. The EDOF group had significantly higher percentage of patients having no difficulty with hobbies and handicrafts (p < 0.05). Eighty-seven percent of the blended subjects and 79% of the EDOF subjects were “very” or “fairly” satisfied with their vision (p = 0.52). The frequency, severity and degree of bother from visual disturbances were comparable between the two groups; however, more subjects in the EDOF group reported severe disturbances (36% vs 4%).Conclusion: Distance and near VA are similar with both IOL designs, but intermediate VA was better with the EDOF IOL resulting in lower difficulty with intermediate tasks such as hobbies and handicrafts. Despite the difference at intermediate VA, satisfaction was similar between the two groups and there were greater reports of severe visual disturbances in the EDOF group.Keywords: ReSTOR, Symfony, multifocal, extended range of vision, cataract surgery