Comparison of different preparation techniques of dried blood spot quality controls in newborn screening for congenital adrenal hyperplasia.
In newborn screening, samples suspected for congenital adrenal hyperplasia (CAH), a potentially lethal inborn error of steroid biosynthesis, need to be confirmed using liquid chromatography-tandem mass spectrometry. Daily quality controls (QCs) for the 2nd-tier CAH assay are not commercially availab...
Guardado en:
Autores principales: | , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Public Library of Science (PLoS)
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/7ca0e03bcdb04bfe8b158e79c92ea220 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:7ca0e03bcdb04bfe8b158e79c92ea220 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:7ca0e03bcdb04bfe8b158e79c92ea2202021-12-02T20:11:16ZComparison of different preparation techniques of dried blood spot quality controls in newborn screening for congenital adrenal hyperplasia.1932-620310.1371/journal.pone.0252091https://doaj.org/article/7ca0e03bcdb04bfe8b158e79c92ea2202021-01-01T00:00:00Zhttps://doi.org/10.1371/journal.pone.0252091https://doaj.org/toc/1932-6203In newborn screening, samples suspected for congenital adrenal hyperplasia (CAH), a potentially lethal inborn error of steroid biosynthesis, need to be confirmed using liquid chromatography-tandem mass spectrometry. Daily quality controls (QCs) for the 2nd-tier CAH assay are not commercially available and are therefore generally prepared within the laboratory. For the first time, we aimed to compare five different QC preparation approaches used in routine diagnostics for CAH on the concentrations of cortisol, 21-deoxycortisol, 11-deoxycortisol, 4-androstenedione and 17-hydroxyprogesterone in dried blood spots. The techniques from Prep1 to Prep5 were tested at two analyte concentrations by spiking aliquots of a steroid-depleted blood, derived from washed erythrocyte suspension and steroid-depleted serum. The preparation processes differed in the sequence of the preparation steps and whether freeze-thaw cycles were used to facilitate blood homogeneity. The five types of dried blood spot QCs were assayed and quantitated in duplicate on five different days using a single calibration row per day. Inter-assay variations less than 15% and concentrations within ±15% of the nominal values were considered acceptable. Results obtained by means of the four dried blood spot QC preparation techniques (Prep1, Prep2, Prep4 and Prep5) were statistically similar and remained within the ±15% ranges in terms of both reproducibility and nominal values. However, concentration results for Prep3 (spiking prior to three freeze-thaw cycles) were significantly lower than the nominal values in this setting, with differences exceeding the ±15% range in many cases despite acceptable inter-assay variations. These findings have implications for the in-house preparation of QC samples in laboratory developed tests for CAH, including 2nd-tier assays in newborn screening.Nóra GrecsóAnita ZádoriÁkos BaráthZsolt GallaGábor RáczCsaba BereczkiPéter MonostoriPublic Library of Science (PLoS)articleMedicineRScienceQENPLoS ONE, Vol 16, Iss 5, p e0252091 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Nóra Grecsó Anita Zádori Ákos Baráth Zsolt Galla Gábor Rácz Csaba Bereczki Péter Monostori Comparison of different preparation techniques of dried blood spot quality controls in newborn screening for congenital adrenal hyperplasia. |
description |
In newborn screening, samples suspected for congenital adrenal hyperplasia (CAH), a potentially lethal inborn error of steroid biosynthesis, need to be confirmed using liquid chromatography-tandem mass spectrometry. Daily quality controls (QCs) for the 2nd-tier CAH assay are not commercially available and are therefore generally prepared within the laboratory. For the first time, we aimed to compare five different QC preparation approaches used in routine diagnostics for CAH on the concentrations of cortisol, 21-deoxycortisol, 11-deoxycortisol, 4-androstenedione and 17-hydroxyprogesterone in dried blood spots. The techniques from Prep1 to Prep5 were tested at two analyte concentrations by spiking aliquots of a steroid-depleted blood, derived from washed erythrocyte suspension and steroid-depleted serum. The preparation processes differed in the sequence of the preparation steps and whether freeze-thaw cycles were used to facilitate blood homogeneity. The five types of dried blood spot QCs were assayed and quantitated in duplicate on five different days using a single calibration row per day. Inter-assay variations less than 15% and concentrations within ±15% of the nominal values were considered acceptable. Results obtained by means of the four dried blood spot QC preparation techniques (Prep1, Prep2, Prep4 and Prep5) were statistically similar and remained within the ±15% ranges in terms of both reproducibility and nominal values. However, concentration results for Prep3 (spiking prior to three freeze-thaw cycles) were significantly lower than the nominal values in this setting, with differences exceeding the ±15% range in many cases despite acceptable inter-assay variations. These findings have implications for the in-house preparation of QC samples in laboratory developed tests for CAH, including 2nd-tier assays in newborn screening. |
format |
article |
author |
Nóra Grecsó Anita Zádori Ákos Baráth Zsolt Galla Gábor Rácz Csaba Bereczki Péter Monostori |
author_facet |
Nóra Grecsó Anita Zádori Ákos Baráth Zsolt Galla Gábor Rácz Csaba Bereczki Péter Monostori |
author_sort |
Nóra Grecsó |
title |
Comparison of different preparation techniques of dried blood spot quality controls in newborn screening for congenital adrenal hyperplasia. |
title_short |
Comparison of different preparation techniques of dried blood spot quality controls in newborn screening for congenital adrenal hyperplasia. |
title_full |
Comparison of different preparation techniques of dried blood spot quality controls in newborn screening for congenital adrenal hyperplasia. |
title_fullStr |
Comparison of different preparation techniques of dried blood spot quality controls in newborn screening for congenital adrenal hyperplasia. |
title_full_unstemmed |
Comparison of different preparation techniques of dried blood spot quality controls in newborn screening for congenital adrenal hyperplasia. |
title_sort |
comparison of different preparation techniques of dried blood spot quality controls in newborn screening for congenital adrenal hyperplasia. |
publisher |
Public Library of Science (PLoS) |
publishDate |
2021 |
url |
https://doaj.org/article/7ca0e03bcdb04bfe8b158e79c92ea220 |
work_keys_str_mv |
AT noragrecso comparisonofdifferentpreparationtechniquesofdriedbloodspotqualitycontrolsinnewbornscreeningforcongenitaladrenalhyperplasia AT anitazadori comparisonofdifferentpreparationtechniquesofdriedbloodspotqualitycontrolsinnewbornscreeningforcongenitaladrenalhyperplasia AT akosbarath comparisonofdifferentpreparationtechniquesofdriedbloodspotqualitycontrolsinnewbornscreeningforcongenitaladrenalhyperplasia AT zsoltgalla comparisonofdifferentpreparationtechniquesofdriedbloodspotqualitycontrolsinnewbornscreeningforcongenitaladrenalhyperplasia AT gaborracz comparisonofdifferentpreparationtechniquesofdriedbloodspotqualitycontrolsinnewbornscreeningforcongenitaladrenalhyperplasia AT csababereczki comparisonofdifferentpreparationtechniquesofdriedbloodspotqualitycontrolsinnewbornscreeningforcongenitaladrenalhyperplasia AT petermonostori comparisonofdifferentpreparationtechniquesofdriedbloodspotqualitycontrolsinnewbornscreeningforcongenitaladrenalhyperplasia |
_version_ |
1718374892428066816 |