Hydrodynamic performance of the dual-chamber oscillating water column device placed over the undulated sea bed
The present study analyzed the efficiency of the dual-chamber oscillating water column device placed over the undulated bottom. The efficiency of the device is studied for various shape parameters such as chamber lengths, the draft of the lip wall of the device, turbine damping coefficients, and rip...
Guardado en:
Autores principales: | , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://doaj.org/article/7d0f37f609ff4f1db06e2e9606935fa5 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:7d0f37f609ff4f1db06e2e9606935fa5 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:7d0f37f609ff4f1db06e2e9606935fa52021-12-04T04:35:10ZHydrodynamic performance of the dual-chamber oscillating water column device placed over the undulated sea bed2352-484710.1016/j.egyr.2021.11.159https://doaj.org/article/7d0f37f609ff4f1db06e2e9606935fa52022-04-01T00:00:00Zhttp://www.sciencedirect.com/science/article/pii/S2352484721013068https://doaj.org/toc/2352-4847The present study analyzed the efficiency of the dual-chamber oscillating water column device placed over the undulated bottom. The efficiency of the device is studied for various shape parameters such as chamber lengths, the draft of the lip wall of the device, turbine damping coefficients, and ripples of the corrugated bottom. It is seen that the efficiency initially increases as the wavenumber increases. However, the efficiency of the device becomes lower for shorter incident wavelength. The amplitude of the resonance becomes higher for device having wider chamber. Similar higher resonance occurs when the turbine damping coefficients and the number of ripples of the corrugated bottom take higher values. An opposite pattern is formed with the variation in draft of the lip wall of the device. The draft of the outer chamber plays a dominant role in enhancing the efficiency as compared to the draft of the inner chamber of the device. Further, the efficiency becomes higher as the turbine damping coefficient takes the higher values.Kshma TrivediSantanu KoleyElsevierarticleDual-chamber OWC-WECEfficiencyRadiationElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENEnergy Reports, Vol 8, Iss , Pp 480-486 (2022) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Dual-chamber OWC-WEC Efficiency Radiation Electrical engineering. Electronics. Nuclear engineering TK1-9971 |
spellingShingle |
Dual-chamber OWC-WEC Efficiency Radiation Electrical engineering. Electronics. Nuclear engineering TK1-9971 Kshma Trivedi Santanu Koley Hydrodynamic performance of the dual-chamber oscillating water column device placed over the undulated sea bed |
description |
The present study analyzed the efficiency of the dual-chamber oscillating water column device placed over the undulated bottom. The efficiency of the device is studied for various shape parameters such as chamber lengths, the draft of the lip wall of the device, turbine damping coefficients, and ripples of the corrugated bottom. It is seen that the efficiency initially increases as the wavenumber increases. However, the efficiency of the device becomes lower for shorter incident wavelength. The amplitude of the resonance becomes higher for device having wider chamber. Similar higher resonance occurs when the turbine damping coefficients and the number of ripples of the corrugated bottom take higher values. An opposite pattern is formed with the variation in draft of the lip wall of the device. The draft of the outer chamber plays a dominant role in enhancing the efficiency as compared to the draft of the inner chamber of the device. Further, the efficiency becomes higher as the turbine damping coefficient takes the higher values. |
format |
article |
author |
Kshma Trivedi Santanu Koley |
author_facet |
Kshma Trivedi Santanu Koley |
author_sort |
Kshma Trivedi |
title |
Hydrodynamic performance of the dual-chamber oscillating water column device placed over the undulated sea bed |
title_short |
Hydrodynamic performance of the dual-chamber oscillating water column device placed over the undulated sea bed |
title_full |
Hydrodynamic performance of the dual-chamber oscillating water column device placed over the undulated sea bed |
title_fullStr |
Hydrodynamic performance of the dual-chamber oscillating water column device placed over the undulated sea bed |
title_full_unstemmed |
Hydrodynamic performance of the dual-chamber oscillating water column device placed over the undulated sea bed |
title_sort |
hydrodynamic performance of the dual-chamber oscillating water column device placed over the undulated sea bed |
publisher |
Elsevier |
publishDate |
2022 |
url |
https://doaj.org/article/7d0f37f609ff4f1db06e2e9606935fa5 |
work_keys_str_mv |
AT kshmatrivedi hydrodynamicperformanceofthedualchamberoscillatingwatercolumndeviceplacedovertheundulatedseabed AT santanukoley hydrodynamicperformanceofthedualchamberoscillatingwatercolumndeviceplacedovertheundulatedseabed |
_version_ |
1718372921309659136 |