Hydrodynamic performance of the dual-chamber oscillating water column device placed over the undulated sea bed

The present study analyzed the efficiency of the dual-chamber oscillating water column device placed over the undulated bottom. The efficiency of the device is studied for various shape parameters such as chamber lengths, the draft of the lip wall of the device, turbine damping coefficients, and rip...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Kshma Trivedi, Santanu Koley
Formato: article
Lenguaje:EN
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://doaj.org/article/7d0f37f609ff4f1db06e2e9606935fa5
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:7d0f37f609ff4f1db06e2e9606935fa5
record_format dspace
spelling oai:doaj.org-article:7d0f37f609ff4f1db06e2e9606935fa52021-12-04T04:35:10ZHydrodynamic performance of the dual-chamber oscillating water column device placed over the undulated sea bed2352-484710.1016/j.egyr.2021.11.159https://doaj.org/article/7d0f37f609ff4f1db06e2e9606935fa52022-04-01T00:00:00Zhttp://www.sciencedirect.com/science/article/pii/S2352484721013068https://doaj.org/toc/2352-4847The present study analyzed the efficiency of the dual-chamber oscillating water column device placed over the undulated bottom. The efficiency of the device is studied for various shape parameters such as chamber lengths, the draft of the lip wall of the device, turbine damping coefficients, and ripples of the corrugated bottom. It is seen that the efficiency initially increases as the wavenumber increases. However, the efficiency of the device becomes lower for shorter incident wavelength. The amplitude of the resonance becomes higher for device having wider chamber. Similar higher resonance occurs when the turbine damping coefficients and the number of ripples of the corrugated bottom take higher values. An opposite pattern is formed with the variation in draft of the lip wall of the device. The draft of the outer chamber plays a dominant role in enhancing the efficiency as compared to the draft of the inner chamber of the device. Further, the efficiency becomes higher as the turbine damping coefficient takes the higher values.Kshma TrivediSantanu KoleyElsevierarticleDual-chamber OWC-WECEfficiencyRadiationElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENEnergy Reports, Vol 8, Iss , Pp 480-486 (2022)
institution DOAJ
collection DOAJ
language EN
topic Dual-chamber OWC-WEC
Efficiency
Radiation
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
spellingShingle Dual-chamber OWC-WEC
Efficiency
Radiation
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
Kshma Trivedi
Santanu Koley
Hydrodynamic performance of the dual-chamber oscillating water column device placed over the undulated sea bed
description The present study analyzed the efficiency of the dual-chamber oscillating water column device placed over the undulated bottom. The efficiency of the device is studied for various shape parameters such as chamber lengths, the draft of the lip wall of the device, turbine damping coefficients, and ripples of the corrugated bottom. It is seen that the efficiency initially increases as the wavenumber increases. However, the efficiency of the device becomes lower for shorter incident wavelength. The amplitude of the resonance becomes higher for device having wider chamber. Similar higher resonance occurs when the turbine damping coefficients and the number of ripples of the corrugated bottom take higher values. An opposite pattern is formed with the variation in draft of the lip wall of the device. The draft of the outer chamber plays a dominant role in enhancing the efficiency as compared to the draft of the inner chamber of the device. Further, the efficiency becomes higher as the turbine damping coefficient takes the higher values.
format article
author Kshma Trivedi
Santanu Koley
author_facet Kshma Trivedi
Santanu Koley
author_sort Kshma Trivedi
title Hydrodynamic performance of the dual-chamber oscillating water column device placed over the undulated sea bed
title_short Hydrodynamic performance of the dual-chamber oscillating water column device placed over the undulated sea bed
title_full Hydrodynamic performance of the dual-chamber oscillating water column device placed over the undulated sea bed
title_fullStr Hydrodynamic performance of the dual-chamber oscillating water column device placed over the undulated sea bed
title_full_unstemmed Hydrodynamic performance of the dual-chamber oscillating water column device placed over the undulated sea bed
title_sort hydrodynamic performance of the dual-chamber oscillating water column device placed over the undulated sea bed
publisher Elsevier
publishDate 2022
url https://doaj.org/article/7d0f37f609ff4f1db06e2e9606935fa5
work_keys_str_mv AT kshmatrivedi hydrodynamicperformanceofthedualchamberoscillatingwatercolumndeviceplacedovertheundulatedseabed
AT santanukoley hydrodynamicperformanceofthedualchamberoscillatingwatercolumndeviceplacedovertheundulatedseabed
_version_ 1718372921309659136