Comparison of cumulative dissipated energy between the Infiniti and Centurion phacoemulsification systems
Ming Chen,1 Erik Anderson,2 Geoffrey Hill,3 John J Chen,4 Thomas Patrianakos2 1Department of Surgery, University of Hawaii, Honolulu, HI, 2Department of Ophthalmology, John H Stroger, Jr Hospital of Cook County, Chicago, IL, 3Department of Ophthalmology, UT Southwestern Medical Center, Dal...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2015
|
Materias: | |
Acceso en línea: | https://doaj.org/article/7e40744ff3c542cfbacc34a309992662 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:7e40744ff3c542cfbacc34a309992662 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:7e40744ff3c542cfbacc34a3099926622021-12-02T06:49:28ZComparison of cumulative dissipated energy between the Infiniti and Centurion phacoemulsification systems1177-5483https://doaj.org/article/7e40744ff3c542cfbacc34a3099926622015-07-01T00:00:00Zhttp://www.dovepress.com/comparison-of-cumulative-dissipated-energy-between-the-infiniti-and-ce-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Ming Chen,1 Erik Anderson,2 Geoffrey Hill,3 John J Chen,4 Thomas Patrianakos2 1Department of Surgery, University of Hawaii, Honolulu, HI, 2Department of Ophthalmology, John H Stroger, Jr Hospital of Cook County, Chicago, IL, 3Department of Ophthalmology, UT Southwestern Medical Center, Dallas, TX, 4Biostatistics Core, John A Burns School of Medicine, University of Hawaii, Honolulu, HI, USA Purpose: To compare cumulative dissipated energy between two phacoemulsification machines. Setting: An ambulatory surgical center, Honolulu, Hawaii, USA. Design: Retrospective chart review. Methods: A total of 2,077 consecutive cases of cataract extraction by phacoemulsification performed by five surgeons from November 2012 to November 2014 were included in the study; 1,021 consecutive cases were performed using the Infiniti Vision System, followed by 1,056 consecutive cases performed using the Centurion Vision System. Results: The Centurion phacoemulsification system required less energy to remove a cataractous lens with an adjusted average energy reduction of 38% (5.09 percent-seconds) (P<0.001) across all surgeons in comparison to the Infiniti phacoemulsification system. The reduction in cumulative dissipated energy was statistically significant for each surgeon, with a range of 29%–45% (2.25–12.54 percent-seconds) (P=0.005–<0.001). Cumulative dissipated energy for both the Infiniti and Centurion systems varied directly with patient age, increasing an average of 2.38 percent-seconds/10 years. Conclusion: The Centurion phacoemulsification system required less energy to remove a cataractous lens in comparison to the Infiniti phacoemulsification system. Keywords: phacoemulsification, cumulative dissipated energy, Centurion Vision System, Infiniti Vision SystemChen MAnderson EHill GChen JJPatrianakos TDove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2015, Iss default, Pp 1367-1372 (2015) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Ophthalmology RE1-994 |
spellingShingle |
Ophthalmology RE1-994 Chen M Anderson E Hill G Chen JJ Patrianakos T Comparison of cumulative dissipated energy between the Infiniti and Centurion phacoemulsification systems |
description |
Ming Chen,1 Erik Anderson,2 Geoffrey Hill,3 John J Chen,4 Thomas Patrianakos2 1Department of Surgery, University of Hawaii, Honolulu, HI, 2Department of Ophthalmology, John H Stroger, Jr Hospital of Cook County, Chicago, IL, 3Department of Ophthalmology, UT Southwestern Medical Center, Dallas, TX, 4Biostatistics Core, John A Burns School of Medicine, University of Hawaii, Honolulu, HI, USA Purpose: To compare cumulative dissipated energy between two phacoemulsification machines. Setting: An ambulatory surgical center, Honolulu, Hawaii, USA. Design: Retrospective chart review. Methods: A total of 2,077 consecutive cases of cataract extraction by phacoemulsification performed by five surgeons from November 2012 to November 2014 were included in the study; 1,021 consecutive cases were performed using the Infiniti Vision System, followed by 1,056 consecutive cases performed using the Centurion Vision System. Results: The Centurion phacoemulsification system required less energy to remove a cataractous lens with an adjusted average energy reduction of 38% (5.09 percent-seconds) (P<0.001) across all surgeons in comparison to the Infiniti phacoemulsification system. The reduction in cumulative dissipated energy was statistically significant for each surgeon, with a range of 29%–45% (2.25–12.54 percent-seconds) (P=0.005–<0.001). Cumulative dissipated energy for both the Infiniti and Centurion systems varied directly with patient age, increasing an average of 2.38 percent-seconds/10 years. Conclusion: The Centurion phacoemulsification system required less energy to remove a cataractous lens in comparison to the Infiniti phacoemulsification system. Keywords: phacoemulsification, cumulative dissipated energy, Centurion Vision System, Infiniti Vision System |
format |
article |
author |
Chen M Anderson E Hill G Chen JJ Patrianakos T |
author_facet |
Chen M Anderson E Hill G Chen JJ Patrianakos T |
author_sort |
Chen M |
title |
Comparison of cumulative dissipated energy between the Infiniti and Centurion phacoemulsification systems |
title_short |
Comparison of cumulative dissipated energy between the Infiniti and Centurion phacoemulsification systems |
title_full |
Comparison of cumulative dissipated energy between the Infiniti and Centurion phacoemulsification systems |
title_fullStr |
Comparison of cumulative dissipated energy between the Infiniti and Centurion phacoemulsification systems |
title_full_unstemmed |
Comparison of cumulative dissipated energy between the Infiniti and Centurion phacoemulsification systems |
title_sort |
comparison of cumulative dissipated energy between the infiniti and centurion phacoemulsification systems |
publisher |
Dove Medical Press |
publishDate |
2015 |
url |
https://doaj.org/article/7e40744ff3c542cfbacc34a309992662 |
work_keys_str_mv |
AT chenm comparisonofcumulativedissipatedenergybetweentheinfinitiandcenturionphacoemulsificationsystems AT andersone comparisonofcumulativedissipatedenergybetweentheinfinitiandcenturionphacoemulsificationsystems AT hillg comparisonofcumulativedissipatedenergybetweentheinfinitiandcenturionphacoemulsificationsystems AT chenjj comparisonofcumulativedissipatedenergybetweentheinfinitiandcenturionphacoemulsificationsystems AT patrianakost comparisonofcumulativedissipatedenergybetweentheinfinitiandcenturionphacoemulsificationsystems |
_version_ |
1718399699736592384 |