Monitoring temporal changes in the specificity of an oral HIV test: a novel application for use in postmarketing surveillance.

<h4>Background</h4>Postmarketing surveillance is routinely conducted to monitor performance of pharmaceuticals and testing devices in the marketplace. However, these surveillance methods are often done retrospectively and, as a result, are not designed to detect issues with performance i...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Joseph R Egger, Kevin J Konty, Jessica M Borrelli, Julia Cummiskey, Susan Blank
Formato: article
Lenguaje:EN
Publicado: Public Library of Science (PLoS) 2010
Materias:
R
Q
Acceso en línea:https://doaj.org/article/7e84f4f1727f4fcf9b36f2ba50c0b343
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:7e84f4f1727f4fcf9b36f2ba50c0b343
record_format dspace
spelling oai:doaj.org-article:7e84f4f1727f4fcf9b36f2ba50c0b3432021-11-18T06:35:45ZMonitoring temporal changes in the specificity of an oral HIV test: a novel application for use in postmarketing surveillance.1932-620310.1371/journal.pone.0012231https://doaj.org/article/7e84f4f1727f4fcf9b36f2ba50c0b3432010-08-01T00:00:00Zhttps://www.ncbi.nlm.nih.gov/pmc/articles/pmid/20811502/pdf/?tool=EBIhttps://doaj.org/toc/1932-6203<h4>Background</h4>Postmarketing surveillance is routinely conducted to monitor performance of pharmaceuticals and testing devices in the marketplace. However, these surveillance methods are often done retrospectively and, as a result, are not designed to detect issues with performance in real-time.<h4>Methods and findings</h4>Using HIV antibody screening test data from New York City STD clinics, we developed a formal, statistical method of prospectively detecting temporal clusters of poor performance of a screening test. From 2005 to 2008, New York City, as well as other states, observed unexpectedly high false-positive (FP) rates in an oral fluid-based rapid test used for screening HIV. We attempted to formally assess whether the performance of this HIV screening test statistically deviated from both local expectation and the manufacturer's claim for the test. Results indicate that there were two significant temporal clusters in the FP rate of the oral HIV test, both of which exceeded the manufacturer's upper limit of the 95% CI for the product. Furthermore, the FP rate of the test varied significantly by both STD clinic and test lot, though not by test operator.<h4>Conclusions</h4>Continuous monitoring of surveillance data has the benefit of providing information regarding test performance, and if conducted in real-time, it can enable programs to examine reasons for poor test performance in close proximity to the occurrence. Techniques used in this study could be a valuable addition for postmarketing surveillance of test performance and may become particularly important with the increase in rapid testing methods.Joseph R EggerKevin J KontyJessica M BorrelliJulia CummiskeySusan BlankPublic Library of Science (PLoS)articleMedicineRScienceQENPLoS ONE, Vol 5, Iss 8, p e12231 (2010)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Joseph R Egger
Kevin J Konty
Jessica M Borrelli
Julia Cummiskey
Susan Blank
Monitoring temporal changes in the specificity of an oral HIV test: a novel application for use in postmarketing surveillance.
description <h4>Background</h4>Postmarketing surveillance is routinely conducted to monitor performance of pharmaceuticals and testing devices in the marketplace. However, these surveillance methods are often done retrospectively and, as a result, are not designed to detect issues with performance in real-time.<h4>Methods and findings</h4>Using HIV antibody screening test data from New York City STD clinics, we developed a formal, statistical method of prospectively detecting temporal clusters of poor performance of a screening test. From 2005 to 2008, New York City, as well as other states, observed unexpectedly high false-positive (FP) rates in an oral fluid-based rapid test used for screening HIV. We attempted to formally assess whether the performance of this HIV screening test statistically deviated from both local expectation and the manufacturer's claim for the test. Results indicate that there were two significant temporal clusters in the FP rate of the oral HIV test, both of which exceeded the manufacturer's upper limit of the 95% CI for the product. Furthermore, the FP rate of the test varied significantly by both STD clinic and test lot, though not by test operator.<h4>Conclusions</h4>Continuous monitoring of surveillance data has the benefit of providing information regarding test performance, and if conducted in real-time, it can enable programs to examine reasons for poor test performance in close proximity to the occurrence. Techniques used in this study could be a valuable addition for postmarketing surveillance of test performance and may become particularly important with the increase in rapid testing methods.
format article
author Joseph R Egger
Kevin J Konty
Jessica M Borrelli
Julia Cummiskey
Susan Blank
author_facet Joseph R Egger
Kevin J Konty
Jessica M Borrelli
Julia Cummiskey
Susan Blank
author_sort Joseph R Egger
title Monitoring temporal changes in the specificity of an oral HIV test: a novel application for use in postmarketing surveillance.
title_short Monitoring temporal changes in the specificity of an oral HIV test: a novel application for use in postmarketing surveillance.
title_full Monitoring temporal changes in the specificity of an oral HIV test: a novel application for use in postmarketing surveillance.
title_fullStr Monitoring temporal changes in the specificity of an oral HIV test: a novel application for use in postmarketing surveillance.
title_full_unstemmed Monitoring temporal changes in the specificity of an oral HIV test: a novel application for use in postmarketing surveillance.
title_sort monitoring temporal changes in the specificity of an oral hiv test: a novel application for use in postmarketing surveillance.
publisher Public Library of Science (PLoS)
publishDate 2010
url https://doaj.org/article/7e84f4f1727f4fcf9b36f2ba50c0b343
work_keys_str_mv AT josephregger monitoringtemporalchangesinthespecificityofanoralhivtestanovelapplicationforuseinpostmarketingsurveillance
AT kevinjkonty monitoringtemporalchangesinthespecificityofanoralhivtestanovelapplicationforuseinpostmarketingsurveillance
AT jessicamborrelli monitoringtemporalchangesinthespecificityofanoralhivtestanovelapplicationforuseinpostmarketingsurveillance
AT juliacummiskey monitoringtemporalchangesinthespecificityofanoralhivtestanovelapplicationforuseinpostmarketingsurveillance
AT susanblank monitoringtemporalchangesinthespecificityofanoralhivtestanovelapplicationforuseinpostmarketingsurveillance
_version_ 1718424424083881984