Effect of curing by different polluted water on the structural behavior of RC slabs

There was a serious water problem especially in the region close to the sewer treatment plants. Therefore, an effort has been made to utilize the waste water from the sewer treatment plants for building purposes, so that the water problem can be greatly minimized and the waste water can be properly...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Majeed Muhannd Waleed, Abd Lubna Mohammed, Abbas Aamer Najim
Formato: article
Lenguaje:EN
Publicado: Institut za istrazivanja i projektovanja u privredi 2021
Materias:
T
Acceso en línea:https://doaj.org/article/7eba89b3178f48f69fc274f67f632b5e
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:7eba89b3178f48f69fc274f67f632b5e
record_format dspace
spelling oai:doaj.org-article:7eba89b3178f48f69fc274f67f632b5e2021-12-05T21:23:13ZEffect of curing by different polluted water on the structural behavior of RC slabs1451-41171821-319710.5937/jaes0-30049https://doaj.org/article/7eba89b3178f48f69fc274f67f632b5e2021-01-01T00:00:00Zhttps://scindeks-clanci.ceon.rs/data/pdf/1451-4117/2021/1451-41172103833M.pdfhttps://doaj.org/toc/1451-4117https://doaj.org/toc/1821-3197There was a serious water problem especially in the region close to the sewer treatment plants. Therefore, an effort has been made to utilize the waste water from the sewer treatment plants for building purposes, so that the water problem can be greatly minimized and the waste water can be properly disposed of for good environmental conservation. Slabs in severe curing conditions performed by hospital waste water and sewer waste water.. This article highlights an experimental analysis on the behavior of concrete foundations in severe curing conditions performed by hospital waste water and sewer waste water. The experiment measured ultimate load, first crack load, load-deflection behavior, stiffness and evaluated the crack pattern of twelve reinforced concrete slabs after curing the specimens for 28 days. The results of the test indicate that the use of hospital and sewer waste water could reduce the strength, stiffness and accelerate damage of tested slabs . Mechanical properties such as compressive strength, elastic modulus, flexural strength, etc. were examined by pouring various concrete samples in the element of cubes, cylinders and prisms, etc. and were concluded to be acceptable.Majeed Muhannd WaleedAbd Lubna MohammedAbbas Aamer NajimInstitut za istrazivanja i projektovanja u privrediarticlefreshwaterwaste waterhospitalsewerultimate loadfirst crackfailure patterndeflectionTechnologyTEngineering (General). Civil engineering (General)TA1-2040ENIstrazivanja i projektovanja za privredu, Vol 19, Iss 3, Pp 833-840 (2021)
institution DOAJ
collection DOAJ
language EN
topic freshwater
waste water
hospital
sewer
ultimate load
first crack
failure pattern
deflection
Technology
T
Engineering (General). Civil engineering (General)
TA1-2040
spellingShingle freshwater
waste water
hospital
sewer
ultimate load
first crack
failure pattern
deflection
Technology
T
Engineering (General). Civil engineering (General)
TA1-2040
Majeed Muhannd Waleed
Abd Lubna Mohammed
Abbas Aamer Najim
Effect of curing by different polluted water on the structural behavior of RC slabs
description There was a serious water problem especially in the region close to the sewer treatment plants. Therefore, an effort has been made to utilize the waste water from the sewer treatment plants for building purposes, so that the water problem can be greatly minimized and the waste water can be properly disposed of for good environmental conservation. Slabs in severe curing conditions performed by hospital waste water and sewer waste water.. This article highlights an experimental analysis on the behavior of concrete foundations in severe curing conditions performed by hospital waste water and sewer waste water. The experiment measured ultimate load, first crack load, load-deflection behavior, stiffness and evaluated the crack pattern of twelve reinforced concrete slabs after curing the specimens for 28 days. The results of the test indicate that the use of hospital and sewer waste water could reduce the strength, stiffness and accelerate damage of tested slabs . Mechanical properties such as compressive strength, elastic modulus, flexural strength, etc. were examined by pouring various concrete samples in the element of cubes, cylinders and prisms, etc. and were concluded to be acceptable.
format article
author Majeed Muhannd Waleed
Abd Lubna Mohammed
Abbas Aamer Najim
author_facet Majeed Muhannd Waleed
Abd Lubna Mohammed
Abbas Aamer Najim
author_sort Majeed Muhannd Waleed
title Effect of curing by different polluted water on the structural behavior of RC slabs
title_short Effect of curing by different polluted water on the structural behavior of RC slabs
title_full Effect of curing by different polluted water on the structural behavior of RC slabs
title_fullStr Effect of curing by different polluted water on the structural behavior of RC slabs
title_full_unstemmed Effect of curing by different polluted water on the structural behavior of RC slabs
title_sort effect of curing by different polluted water on the structural behavior of rc slabs
publisher Institut za istrazivanja i projektovanja u privredi
publishDate 2021
url https://doaj.org/article/7eba89b3178f48f69fc274f67f632b5e
work_keys_str_mv AT majeedmuhanndwaleed effectofcuringbydifferentpollutedwateronthestructuralbehaviorofrcslabs
AT abdlubnamohammed effectofcuringbydifferentpollutedwateronthestructuralbehaviorofrcslabs
AT abbasaamernajim effectofcuringbydifferentpollutedwateronthestructuralbehaviorofrcslabs
_version_ 1718371011205791744