Experimental Investigation into the Strength of Single Sided Silicone Glazing Joints Under Blast Loading
An experimental study has taken place to quantify the strength of single sided structural silicone glazing joints under blast loading. The structural silicone specimens in this experiment were tested using a high-speed servo-hydraulic test machine at varying rates, representative of that experience...