Inverted internal limiting membrane (ILM) flap technique for macular hole closure: patient selection and special considerations
Daraius Shroff, Priyanka Gupta, Neelam Atri, Charu Gupta, Cyrus ShroffShroff Eye Centre, Vitreoretinal Services, New Delhi 110048, IndiaAbstract: This paper reviews the current status of the newer inverted internal limiting membrane flap technique for macular hole surgery. It gives an overview of th...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2019
|
Materias: | |
Acceso en línea: | https://doaj.org/article/80b719a132f24194b9ba4144ca4ec0ed |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:80b719a132f24194b9ba4144ca4ec0ed |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:80b719a132f24194b9ba4144ca4ec0ed2021-12-02T03:22:01ZInverted internal limiting membrane (ILM) flap technique for macular hole closure: patient selection and special considerations1177-5483https://doaj.org/article/80b719a132f24194b9ba4144ca4ec0ed2019-04-01T00:00:00Zhttps://www.dovepress.com/inverted-internal-limiting-membrane-ilm-flap-technique-for-macular-hol-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Daraius Shroff, Priyanka Gupta, Neelam Atri, Charu Gupta, Cyrus ShroffShroff Eye Centre, Vitreoretinal Services, New Delhi 110048, IndiaAbstract: This paper reviews the current status of the newer inverted internal limiting membrane flap technique for macular hole surgery. It gives an overview of the importance of patient selection and special considerations along with variations in technique. It discusses the pathophysiology and how the technique has been an important addition in the armamentarium of vitreoretinal surgeons to attain better anatomical as well as functional results in challenging situations.Keywords: macular hole, inverted internal limiting membrane flap technique, optical coherence tomographyShroff DGupta PAtri NGupta CShroff CDove Medical PressarticleMacular holeinverted internal limiting membrane flap techniqueoptical coherence tomographyOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 13, Pp 671-678 (2019) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Macular hole inverted internal limiting membrane flap technique optical coherence tomography Ophthalmology RE1-994 |
spellingShingle |
Macular hole inverted internal limiting membrane flap technique optical coherence tomography Ophthalmology RE1-994 Shroff D Gupta P Atri N Gupta C Shroff C Inverted internal limiting membrane (ILM) flap technique for macular hole closure: patient selection and special considerations |
description |
Daraius Shroff, Priyanka Gupta, Neelam Atri, Charu Gupta, Cyrus ShroffShroff Eye Centre, Vitreoretinal Services, New Delhi 110048, IndiaAbstract: This paper reviews the current status of the newer inverted internal limiting membrane flap technique for macular hole surgery. It gives an overview of the importance of patient selection and special considerations along with variations in technique. It discusses the pathophysiology and how the technique has been an important addition in the armamentarium of vitreoretinal surgeons to attain better anatomical as well as functional results in challenging situations.Keywords: macular hole, inverted internal limiting membrane flap technique, optical coherence tomography |
format |
article |
author |
Shroff D Gupta P Atri N Gupta C Shroff C |
author_facet |
Shroff D Gupta P Atri N Gupta C Shroff C |
author_sort |
Shroff D |
title |
Inverted internal limiting membrane (ILM) flap technique for macular hole closure: patient selection and special considerations |
title_short |
Inverted internal limiting membrane (ILM) flap technique for macular hole closure: patient selection and special considerations |
title_full |
Inverted internal limiting membrane (ILM) flap technique for macular hole closure: patient selection and special considerations |
title_fullStr |
Inverted internal limiting membrane (ILM) flap technique for macular hole closure: patient selection and special considerations |
title_full_unstemmed |
Inverted internal limiting membrane (ILM) flap technique for macular hole closure: patient selection and special considerations |
title_sort |
inverted internal limiting membrane (ilm) flap technique for macular hole closure: patient selection and special considerations |
publisher |
Dove Medical Press |
publishDate |
2019 |
url |
https://doaj.org/article/80b719a132f24194b9ba4144ca4ec0ed |
work_keys_str_mv |
AT shroffd invertedinternallimitingmembraneilmflaptechniqueformacularholeclosurepatientselectionandspecialconsiderations AT guptap invertedinternallimitingmembraneilmflaptechniqueformacularholeclosurepatientselectionandspecialconsiderations AT atrin invertedinternallimitingmembraneilmflaptechniqueformacularholeclosurepatientselectionandspecialconsiderations AT guptac invertedinternallimitingmembraneilmflaptechniqueformacularholeclosurepatientselectionandspecialconsiderations AT shroffc invertedinternallimitingmembraneilmflaptechniqueformacularholeclosurepatientselectionandspecialconsiderations |
_version_ |
1718401803338383360 |