Procedure for the selection and evaluation of prefabricated housing buildings for the implementation of green roofs in the context of Urban Heat Island mitigation. The example of Wrocław, Poland.

The assessment of the suitability of existing buildings for implementation of green roofs is an important research issue, especially in the context of Urban Heat Island (UHI), the negative impacts of which are locally exacerbated by the global warming. The studies carried out so far have covered a v...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Justyna Rubaszek, Mariusz Szymanowski, Adam Michalski, Radosław Tatko, Marta Weber-Siwirska
Formato: article
Lenguaje:EN
Publicado: Public Library of Science (PLoS) 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/8106d2fc64d348db8b0e269752cc628c
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:The assessment of the suitability of existing buildings for implementation of green roofs is an important research issue, especially in the context of Urban Heat Island (UHI), the negative impacts of which are locally exacerbated by the global warming. The studies carried out so far have covered a variety of buildings and have taken into account a range of different conditions. Relatively little attention has been paid to the possibilities of greening the roofs of prefabricated apartment blocks from the second half of the 20th century in the context of the potential climate effect. Yet, these buildings are found in many cities around the world, and seem in fact attractive for greening. In view of the above, we proposed a three-stage investigatory procedure to: (I) identify and classify buildings based on the number of floors and the rooftop available area; (II) select buildings by designating priority areas depending on the highest UHI intensity and roof density; (III) analyse the roof load capacity to develop retrofit scenarios. The procedure was applied to prefabricated housing estates built in the 1970s and 1980s in Wrocław, Poland. The research shows that there are 1962 buildings of different heights and roof area of 722405 m2, of which 480 buildings with a roof area of 122749.1 m2 were selected for greening within priority areas. The structure of the studied roofs was not designed to carry additional loads, which requires the application of complementary solutions. Scenario 1 assumes extensive greening provided that the existing ventilated roof is strengthened, scenario 2 -semi-intensive greening, which however requires the conversion of the ventilated roof to a non-ventilated one. The presented procedure can be applied in any other city with prefabricated apartment blocks and available UHI data, and serve to support the decision to implement green roofs to mitigate UHI.