Time-varying regularity of changes in biomechanical properties of the corneas after removal of anterior corneal tissue

Abstract Background The corneal biomechanical properties with the prolongation of time after corneal refractive surgery are important for providing a mechanical basis for the occurrence of clinical phenomena such as iatrogenic keratectasia and refractive regression. The aim of this study was to expl...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Di Zhang, Xiao Qin, Haixia Zhang, Lin Li
Formato: article
Lenguaje:EN
Publicado: BMC 2021
Materias:
Acceso en línea:https://doaj.org/article/810e60cd1f1d4bd0a2e713245583d842
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:810e60cd1f1d4bd0a2e713245583d842
record_format dspace
spelling oai:doaj.org-article:810e60cd1f1d4bd0a2e713245583d8422021-11-21T12:12:19ZTime-varying regularity of changes in biomechanical properties of the corneas after removal of anterior corneal tissue10.1186/s12938-021-00948-71475-925Xhttps://doaj.org/article/810e60cd1f1d4bd0a2e713245583d8422021-11-01T00:00:00Zhttps://doi.org/10.1186/s12938-021-00948-7https://doaj.org/toc/1475-925XAbstract Background The corneal biomechanical properties with the prolongation of time after corneal refractive surgery are important for providing a mechanical basis for the occurrence of clinical phenomena such as iatrogenic keratectasia and refractive regression. The aim of this study was to explore the changes of corneal elastic modulus, and stress relaxation properties from the 6-month follow-up observations of rabbits after a removal of anterior corneal tissue in simulation to corneal refractive surgery. Methods The anterior corneal tissue, 6 mm in diameter and 30–50% of the original corneal thickness, the left eye of the rabbit was removed, and the right eye was kept as the control. The rabbits were normally raised and nursed for 6 months, during which corneal morphology data, and both of corneal hysteresis (CH) and corneal resistance factor (CRF) were gathered. Uniaxial tensile tests of corneal strips were performed at months 1, 3, and 6 from 7 animals, and corneal collagen fibrils were observed at months 1, 3, and 6 from 1 rabbit, respectively. Results Compared with the control group, there were statistical differences in the curvature radius at week 2 and month 3, and both CH and CRF at months 1, 2, and 6 in experiment group; there were statistical differences in elastic modulus at 1, 3, and month 6, and stress relaxation degree at month 3 in experiment group. The differences in corneal elastic modulus, stress relaxation degree and the total number of collagen fibrils between experiment and control groups varied gradually with time, and showed significant changes at the 3rd month after the treatment. Conclusions Corneas after a removal of anterior corneal tissue undergo dynamic changes in corneal morphology and biomechanical properties. The first 3 months after treatment could be a critical period. The variation of corneal biomechanical properties is worth considering in predicting corneal deformation after a removal of anterior corneal tissue.Di ZhangXiao QinHaixia ZhangLin LiBMCarticleCorneal elastic modulusStress relaxationUniaxial testsCorneal refractive surgeryMedical technologyR855-855.5ENBioMedical Engineering OnLine, Vol 20, Iss 1, Pp 1-14 (2021)
institution DOAJ
collection DOAJ
language EN
topic Corneal elastic modulus
Stress relaxation
Uniaxial tests
Corneal refractive surgery
Medical technology
R855-855.5
spellingShingle Corneal elastic modulus
Stress relaxation
Uniaxial tests
Corneal refractive surgery
Medical technology
R855-855.5
Di Zhang
Xiao Qin
Haixia Zhang
Lin Li
Time-varying regularity of changes in biomechanical properties of the corneas after removal of anterior corneal tissue
description Abstract Background The corneal biomechanical properties with the prolongation of time after corneal refractive surgery are important for providing a mechanical basis for the occurrence of clinical phenomena such as iatrogenic keratectasia and refractive regression. The aim of this study was to explore the changes of corneal elastic modulus, and stress relaxation properties from the 6-month follow-up observations of rabbits after a removal of anterior corneal tissue in simulation to corneal refractive surgery. Methods The anterior corneal tissue, 6 mm in diameter and 30–50% of the original corneal thickness, the left eye of the rabbit was removed, and the right eye was kept as the control. The rabbits were normally raised and nursed for 6 months, during which corneal morphology data, and both of corneal hysteresis (CH) and corneal resistance factor (CRF) were gathered. Uniaxial tensile tests of corneal strips were performed at months 1, 3, and 6 from 7 animals, and corneal collagen fibrils were observed at months 1, 3, and 6 from 1 rabbit, respectively. Results Compared with the control group, there were statistical differences in the curvature radius at week 2 and month 3, and both CH and CRF at months 1, 2, and 6 in experiment group; there were statistical differences in elastic modulus at 1, 3, and month 6, and stress relaxation degree at month 3 in experiment group. The differences in corneal elastic modulus, stress relaxation degree and the total number of collagen fibrils between experiment and control groups varied gradually with time, and showed significant changes at the 3rd month after the treatment. Conclusions Corneas after a removal of anterior corneal tissue undergo dynamic changes in corneal morphology and biomechanical properties. The first 3 months after treatment could be a critical period. The variation of corneal biomechanical properties is worth considering in predicting corneal deformation after a removal of anterior corneal tissue.
format article
author Di Zhang
Xiao Qin
Haixia Zhang
Lin Li
author_facet Di Zhang
Xiao Qin
Haixia Zhang
Lin Li
author_sort Di Zhang
title Time-varying regularity of changes in biomechanical properties of the corneas after removal of anterior corneal tissue
title_short Time-varying regularity of changes in biomechanical properties of the corneas after removal of anterior corneal tissue
title_full Time-varying regularity of changes in biomechanical properties of the corneas after removal of anterior corneal tissue
title_fullStr Time-varying regularity of changes in biomechanical properties of the corneas after removal of anterior corneal tissue
title_full_unstemmed Time-varying regularity of changes in biomechanical properties of the corneas after removal of anterior corneal tissue
title_sort time-varying regularity of changes in biomechanical properties of the corneas after removal of anterior corneal tissue
publisher BMC
publishDate 2021
url https://doaj.org/article/810e60cd1f1d4bd0a2e713245583d842
work_keys_str_mv AT dizhang timevaryingregularityofchangesinbiomechanicalpropertiesofthecorneasafterremovalofanteriorcornealtissue
AT xiaoqin timevaryingregularityofchangesinbiomechanicalpropertiesofthecorneasafterremovalofanteriorcornealtissue
AT haixiazhang timevaryingregularityofchangesinbiomechanicalpropertiesofthecorneasafterremovalofanteriorcornealtissue
AT linli timevaryingregularityofchangesinbiomechanicalpropertiesofthecorneasafterremovalofanteriorcornealtissue
_version_ 1718419133403496448