A System-Level Suppression Method for DC Bias Based on Reverse Unbalanced Currents in the Same Transmission Section

Conventional dc bias suppression strategies mainly rely on a single type of device, such as blocking capacitor or blocking resistance. However, these methods are passive palliatives and cannot restrain dc bias currents from the sources. In the light of this, a system-level suppression method for dc...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Shumin Ma, Xiangning Lin, Zhengtian Li, Neng Jin, Zirui Rong, Peifu Zhang, Haibo Xu
Formato: article
Lenguaje:EN
Publicado: IEEE 2021
Materias:
Acceso en línea:https://doaj.org/article/81b5679ce61f4811b886acd55d2370e9
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:81b5679ce61f4811b886acd55d2370e9
record_format dspace
spelling oai:doaj.org-article:81b5679ce61f4811b886acd55d2370e92021-11-19T00:06:55ZA System-Level Suppression Method for DC Bias Based on Reverse Unbalanced Currents in the Same Transmission Section2169-353610.1109/ACCESS.2021.3108555https://doaj.org/article/81b5679ce61f4811b886acd55d2370e92021-01-01T00:00:00Zhttps://ieeexplore.ieee.org/document/9524637/https://doaj.org/toc/2169-3536Conventional dc bias suppression strategies mainly rely on a single type of device, such as blocking capacitor or blocking resistance. However, these methods are passive palliatives and cannot restrain dc bias currents from the sources. In the light of this, a system-level suppression method for dc bias is proposed in this paper. The average value of currents flowing through the earth is offset by actively generating unbalanced current through other dc projects in the same transmission section, which will reduce the currents flowing into the neutral transformers and alleviate the negative impacts of dc bias. First, the feasibility of the same section dc continuous power support is analyzed. Then the dc bias suppression strategy based on reverse unbalanced currents is elaborated. By scanning all the theoretical operable solutions of unbalanced current generation modes and the possible switching combinations of blocking capacitors, the optimal dc bias suppression solution is output considering the number of adjusted dc projects, the overload margin of dc projects and neutral dc currents of transformers. The effectiveness and superiority of the proposed method are verified by comparative case studies of the East China power grid.Shumin MaXiangning LinZhengtian LiNeng JinZirui RongPeifu ZhangHaibo XuIEEEarticleDc biassystem-level suppression methodreverse unbalanced currentsElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENIEEE Access, Vol 9, Pp 126967-126975 (2021)
institution DOAJ
collection DOAJ
language EN
topic Dc bias
system-level suppression method
reverse unbalanced currents
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
spellingShingle Dc bias
system-level suppression method
reverse unbalanced currents
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
Shumin Ma
Xiangning Lin
Zhengtian Li
Neng Jin
Zirui Rong
Peifu Zhang
Haibo Xu
A System-Level Suppression Method for DC Bias Based on Reverse Unbalanced Currents in the Same Transmission Section
description Conventional dc bias suppression strategies mainly rely on a single type of device, such as blocking capacitor or blocking resistance. However, these methods are passive palliatives and cannot restrain dc bias currents from the sources. In the light of this, a system-level suppression method for dc bias is proposed in this paper. The average value of currents flowing through the earth is offset by actively generating unbalanced current through other dc projects in the same transmission section, which will reduce the currents flowing into the neutral transformers and alleviate the negative impacts of dc bias. First, the feasibility of the same section dc continuous power support is analyzed. Then the dc bias suppression strategy based on reverse unbalanced currents is elaborated. By scanning all the theoretical operable solutions of unbalanced current generation modes and the possible switching combinations of blocking capacitors, the optimal dc bias suppression solution is output considering the number of adjusted dc projects, the overload margin of dc projects and neutral dc currents of transformers. The effectiveness and superiority of the proposed method are verified by comparative case studies of the East China power grid.
format article
author Shumin Ma
Xiangning Lin
Zhengtian Li
Neng Jin
Zirui Rong
Peifu Zhang
Haibo Xu
author_facet Shumin Ma
Xiangning Lin
Zhengtian Li
Neng Jin
Zirui Rong
Peifu Zhang
Haibo Xu
author_sort Shumin Ma
title A System-Level Suppression Method for DC Bias Based on Reverse Unbalanced Currents in the Same Transmission Section
title_short A System-Level Suppression Method for DC Bias Based on Reverse Unbalanced Currents in the Same Transmission Section
title_full A System-Level Suppression Method for DC Bias Based on Reverse Unbalanced Currents in the Same Transmission Section
title_fullStr A System-Level Suppression Method for DC Bias Based on Reverse Unbalanced Currents in the Same Transmission Section
title_full_unstemmed A System-Level Suppression Method for DC Bias Based on Reverse Unbalanced Currents in the Same Transmission Section
title_sort system-level suppression method for dc bias based on reverse unbalanced currents in the same transmission section
publisher IEEE
publishDate 2021
url https://doaj.org/article/81b5679ce61f4811b886acd55d2370e9
work_keys_str_mv AT shuminma asystemlevelsuppressionmethodfordcbiasbasedonreverseunbalancedcurrentsinthesametransmissionsection
AT xiangninglin asystemlevelsuppressionmethodfordcbiasbasedonreverseunbalancedcurrentsinthesametransmissionsection
AT zhengtianli asystemlevelsuppressionmethodfordcbiasbasedonreverseunbalancedcurrentsinthesametransmissionsection
AT nengjin asystemlevelsuppressionmethodfordcbiasbasedonreverseunbalancedcurrentsinthesametransmissionsection
AT ziruirong asystemlevelsuppressionmethodfordcbiasbasedonreverseunbalancedcurrentsinthesametransmissionsection
AT peifuzhang asystemlevelsuppressionmethodfordcbiasbasedonreverseunbalancedcurrentsinthesametransmissionsection
AT haiboxu asystemlevelsuppressionmethodfordcbiasbasedonreverseunbalancedcurrentsinthesametransmissionsection
AT shuminma systemlevelsuppressionmethodfordcbiasbasedonreverseunbalancedcurrentsinthesametransmissionsection
AT xiangninglin systemlevelsuppressionmethodfordcbiasbasedonreverseunbalancedcurrentsinthesametransmissionsection
AT zhengtianli systemlevelsuppressionmethodfordcbiasbasedonreverseunbalancedcurrentsinthesametransmissionsection
AT nengjin systemlevelsuppressionmethodfordcbiasbasedonreverseunbalancedcurrentsinthesametransmissionsection
AT ziruirong systemlevelsuppressionmethodfordcbiasbasedonreverseunbalancedcurrentsinthesametransmissionsection
AT peifuzhang systemlevelsuppressionmethodfordcbiasbasedonreverseunbalancedcurrentsinthesametransmissionsection
AT haiboxu systemlevelsuppressionmethodfordcbiasbasedonreverseunbalancedcurrentsinthesametransmissionsection
_version_ 1718420620430016512