Non-invasive detection of iron deficiency by fluorescence measurement of erythrocyte zinc protoporphyrin in the lip

Iron deficiency, the most common health problem in the world, has required a blood test for diagnosis. Here, the authors show that iron deficiency can be detected non-invasively and quickly by measuring the fluorescence of red blood cell zinc protoporphyrin in the microcirculation of the lip.

Guardado en:
Detalles Bibliográficos
Autores principales: Georg Hennig, Christian Homann, Ilknur Teksan, Uwe Hasbargen, Stephan Hasmüller, Lesca M. Holdt, Nadia Khaled, Ronald Sroka, Thomas Stauch, Herbert Stepp, Michael Vogeser, Gary M. Brittenham
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2016
Materias:
Q
Acceso en línea:https://doaj.org/article/81edb22ec59d40d1b430c9edc8409188
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:81edb22ec59d40d1b430c9edc8409188
record_format dspace
spelling oai:doaj.org-article:81edb22ec59d40d1b430c9edc84091882021-12-02T15:34:55ZNon-invasive detection of iron deficiency by fluorescence measurement of erythrocyte zinc protoporphyrin in the lip10.1038/ncomms107762041-1723https://doaj.org/article/81edb22ec59d40d1b430c9edc84091882016-02-01T00:00:00Zhttps://doi.org/10.1038/ncomms10776https://doaj.org/toc/2041-1723Iron deficiency, the most common health problem in the world, has required a blood test for diagnosis. Here, the authors show that iron deficiency can be detected non-invasively and quickly by measuring the fluorescence of red blood cell zinc protoporphyrin in the microcirculation of the lip.Georg HennigChristian HomannIlknur TeksanUwe HasbargenStephan HasmüllerLesca M. HoldtNadia KhaledRonald SrokaThomas StauchHerbert SteppMichael VogeserGary M. BrittenhamNature PortfolioarticleScienceQENNature Communications, Vol 7, Iss 1, Pp 1-8 (2016)
institution DOAJ
collection DOAJ
language EN
topic Science
Q
spellingShingle Science
Q
Georg Hennig
Christian Homann
Ilknur Teksan
Uwe Hasbargen
Stephan Hasmüller
Lesca M. Holdt
Nadia Khaled
Ronald Sroka
Thomas Stauch
Herbert Stepp
Michael Vogeser
Gary M. Brittenham
Non-invasive detection of iron deficiency by fluorescence measurement of erythrocyte zinc protoporphyrin in the lip
description Iron deficiency, the most common health problem in the world, has required a blood test for diagnosis. Here, the authors show that iron deficiency can be detected non-invasively and quickly by measuring the fluorescence of red blood cell zinc protoporphyrin in the microcirculation of the lip.
format article
author Georg Hennig
Christian Homann
Ilknur Teksan
Uwe Hasbargen
Stephan Hasmüller
Lesca M. Holdt
Nadia Khaled
Ronald Sroka
Thomas Stauch
Herbert Stepp
Michael Vogeser
Gary M. Brittenham
author_facet Georg Hennig
Christian Homann
Ilknur Teksan
Uwe Hasbargen
Stephan Hasmüller
Lesca M. Holdt
Nadia Khaled
Ronald Sroka
Thomas Stauch
Herbert Stepp
Michael Vogeser
Gary M. Brittenham
author_sort Georg Hennig
title Non-invasive detection of iron deficiency by fluorescence measurement of erythrocyte zinc protoporphyrin in the lip
title_short Non-invasive detection of iron deficiency by fluorescence measurement of erythrocyte zinc protoporphyrin in the lip
title_full Non-invasive detection of iron deficiency by fluorescence measurement of erythrocyte zinc protoporphyrin in the lip
title_fullStr Non-invasive detection of iron deficiency by fluorescence measurement of erythrocyte zinc protoporphyrin in the lip
title_full_unstemmed Non-invasive detection of iron deficiency by fluorescence measurement of erythrocyte zinc protoporphyrin in the lip
title_sort non-invasive detection of iron deficiency by fluorescence measurement of erythrocyte zinc protoporphyrin in the lip
publisher Nature Portfolio
publishDate 2016
url https://doaj.org/article/81edb22ec59d40d1b430c9edc8409188
work_keys_str_mv AT georghennig noninvasivedetectionofirondeficiencybyfluorescencemeasurementoferythrocytezincprotoporphyrininthelip
AT christianhomann noninvasivedetectionofirondeficiencybyfluorescencemeasurementoferythrocytezincprotoporphyrininthelip
AT ilknurteksan noninvasivedetectionofirondeficiencybyfluorescencemeasurementoferythrocytezincprotoporphyrininthelip
AT uwehasbargen noninvasivedetectionofirondeficiencybyfluorescencemeasurementoferythrocytezincprotoporphyrininthelip
AT stephanhasmuller noninvasivedetectionofirondeficiencybyfluorescencemeasurementoferythrocytezincprotoporphyrininthelip
AT lescamholdt noninvasivedetectionofirondeficiencybyfluorescencemeasurementoferythrocytezincprotoporphyrininthelip
AT nadiakhaled noninvasivedetectionofirondeficiencybyfluorescencemeasurementoferythrocytezincprotoporphyrininthelip
AT ronaldsroka noninvasivedetectionofirondeficiencybyfluorescencemeasurementoferythrocytezincprotoporphyrininthelip
AT thomasstauch noninvasivedetectionofirondeficiencybyfluorescencemeasurementoferythrocytezincprotoporphyrininthelip
AT herbertstepp noninvasivedetectionofirondeficiencybyfluorescencemeasurementoferythrocytezincprotoporphyrininthelip
AT michaelvogeser noninvasivedetectionofirondeficiencybyfluorescencemeasurementoferythrocytezincprotoporphyrininthelip
AT garymbrittenham noninvasivedetectionofirondeficiencybyfluorescencemeasurementoferythrocytezincprotoporphyrininthelip
_version_ 1718386729086353408