Dynamic Quadrilateral Characteristic-Based Distance Relays for Transmission Lines Equipped with TCSC

A two-fold adaptive dynamic quadrilateral relay is developed in this research for protecting Thyristor-Controlled Series Compensator (TCSC)-compensated transmission lines (TLs). By investigating a new tilt angle and modifying the Takagi method to recognize the fault zone identifier, the proposed rel...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Ghada M. Abo-Hamad, Doaa Khalil Ibrahim, Essam Aboul Zahab, Ahmed F. Zobaa
Formato: article
Lenguaje:EN
Publicado: MDPI AG 2021
Materias:
T
Acceso en línea:https://doaj.org/article/829d3933368c4586a4fc249a9bf7b70d
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:829d3933368c4586a4fc249a9bf7b70d
record_format dspace
spelling oai:doaj.org-article:829d3933368c4586a4fc249a9bf7b70d2021-11-11T15:52:44ZDynamic Quadrilateral Characteristic-Based Distance Relays for Transmission Lines Equipped with TCSC10.3390/en142170741996-1073https://doaj.org/article/829d3933368c4586a4fc249a9bf7b70d2021-10-01T00:00:00Zhttps://www.mdpi.com/1996-1073/14/21/7074https://doaj.org/toc/1996-1073A two-fold adaptive dynamic quadrilateral relay is developed in this research for protecting Thyristor-Controlled Series Compensator (TCSC)-compensated transmission lines (TLs). By investigating a new tilt angle and modifying the Takagi method to recognize the fault zone identifier, the proposed relay adapts its reactive reach and resistive reach separately and independently. The investigated tilt angle and identified fault zone use the TCSC reactance to compensate its effect on the TL parameters and system homogeneity. Excessive tests are simulated by MATLAB on the non-homogenous network, IEEE-9 bus system and further tests are carried out on IEEE-39 bus system in order to generalize and validate the efficiency of the proposed approach. The designed trip boundaries are able to detect wide range of resistive faults under all TCSC modes of operations. The proposed approach is easy to implement as there no need for data synchronization or a high level of computation and filtration. Moreover, the proposed adaptive dynamic relay can be applied for non-homogeneity systems and short as well as long TLs which are either TCSC-compensated or -uncompensated TLs.Ghada M. Abo-HamadDoaa Khalil IbrahimEssam Aboul ZahabAhmed F. ZobaaMDPI AGarticledistance relayfault resistancequadrilateral characteristicresistance and reactance elementsThyristor Controlled Series Compensator (TCSC)TechnologyTENEnergies, Vol 14, Iss 7074, p 7074 (2021)
institution DOAJ
collection DOAJ
language EN
topic distance relay
fault resistance
quadrilateral characteristic
resistance and reactance elements
Thyristor Controlled Series Compensator (TCSC)
Technology
T
spellingShingle distance relay
fault resistance
quadrilateral characteristic
resistance and reactance elements
Thyristor Controlled Series Compensator (TCSC)
Technology
T
Ghada M. Abo-Hamad
Doaa Khalil Ibrahim
Essam Aboul Zahab
Ahmed F. Zobaa
Dynamic Quadrilateral Characteristic-Based Distance Relays for Transmission Lines Equipped with TCSC
description A two-fold adaptive dynamic quadrilateral relay is developed in this research for protecting Thyristor-Controlled Series Compensator (TCSC)-compensated transmission lines (TLs). By investigating a new tilt angle and modifying the Takagi method to recognize the fault zone identifier, the proposed relay adapts its reactive reach and resistive reach separately and independently. The investigated tilt angle and identified fault zone use the TCSC reactance to compensate its effect on the TL parameters and system homogeneity. Excessive tests are simulated by MATLAB on the non-homogenous network, IEEE-9 bus system and further tests are carried out on IEEE-39 bus system in order to generalize and validate the efficiency of the proposed approach. The designed trip boundaries are able to detect wide range of resistive faults under all TCSC modes of operations. The proposed approach is easy to implement as there no need for data synchronization or a high level of computation and filtration. Moreover, the proposed adaptive dynamic relay can be applied for non-homogeneity systems and short as well as long TLs which are either TCSC-compensated or -uncompensated TLs.
format article
author Ghada M. Abo-Hamad
Doaa Khalil Ibrahim
Essam Aboul Zahab
Ahmed F. Zobaa
author_facet Ghada M. Abo-Hamad
Doaa Khalil Ibrahim
Essam Aboul Zahab
Ahmed F. Zobaa
author_sort Ghada M. Abo-Hamad
title Dynamic Quadrilateral Characteristic-Based Distance Relays for Transmission Lines Equipped with TCSC
title_short Dynamic Quadrilateral Characteristic-Based Distance Relays for Transmission Lines Equipped with TCSC
title_full Dynamic Quadrilateral Characteristic-Based Distance Relays for Transmission Lines Equipped with TCSC
title_fullStr Dynamic Quadrilateral Characteristic-Based Distance Relays for Transmission Lines Equipped with TCSC
title_full_unstemmed Dynamic Quadrilateral Characteristic-Based Distance Relays for Transmission Lines Equipped with TCSC
title_sort dynamic quadrilateral characteristic-based distance relays for transmission lines equipped with tcsc
publisher MDPI AG
publishDate 2021
url https://doaj.org/article/829d3933368c4586a4fc249a9bf7b70d
work_keys_str_mv AT ghadamabohamad dynamicquadrilateralcharacteristicbaseddistancerelaysfortransmissionlinesequippedwithtcsc
AT doaakhalilibrahim dynamicquadrilateralcharacteristicbaseddistancerelaysfortransmissionlinesequippedwithtcsc
AT essamaboulzahab dynamicquadrilateralcharacteristicbaseddistancerelaysfortransmissionlinesequippedwithtcsc
AT ahmedfzobaa dynamicquadrilateralcharacteristicbaseddistancerelaysfortransmissionlinesequippedwithtcsc
_version_ 1718433119247269888