A CHOICE OF ACCEPTABLE SECTIONS OF ELECTRIC WIRES AND CABLES IN ON-BOARD CIRCUITS OF AIRCRAFT ELECTRICAL EQUIPMENT

Purpose. Implementation of choice of maximum permissible sections Sil of the uninsulated wires and insulated wires (cables) with copper (aluminum) cores (shells) in the on-board power circuits of electrical equipment of different aircrafts with AC current of frequency f>50 Hz. Methodology. Theore...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autor principal: M. I. Baranov
Formato: article
Lenguaje:EN
RU
UK
Publicado: National Technical University "Kharkiv Polytechnic Institute" 2020
Materias:
Acceso en línea:https://doaj.org/article/82fc1bddf6c64fe2ab42ea22684bf656
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:Purpose. Implementation of choice of maximum permissible sections Sil of the uninsulated wires and insulated wires (cables) with copper (aluminum) cores (shells) in the on-board power circuits of electrical equipment of different aircrafts with AC current of frequency f>50 Hz. Methodology. Theoretical bases of the electrical engineering, electrophysics bases of technique of high voltage and high pulsed currents, applied thermal physics. Results. The engineering approach is developed for a calculation choice on the condition of thermal resistibility of aircraft cable-conductor products (CCP) of maximum permissible sections Sil of the uninsulated wires, insulated wires and cables with copper (aluminum) cores (shells), polyvinyl chloride (PVC), rubber (R) and polyethylene (PET) insulation, on which in malfunction of operation of on-board aircraft network with AC frequency of f>50 Hz flows of ik(t) current at single phase short circuit (SC) with given amplitude-temporal parameters. It is determined that in the on-board power circuits of electrical equipment of aircrafts (f=400 Hz; for permanent time of slump of Ta=3 ms of аperiodic constituent of current of SC) maximum permissible amplitudes of current density of δilm≈Imk/Sil of single phase SC at time of its disconnecting tkC=5 ms in the on-board network of aircraft without dependence on the numerical value of amplitude Imk of the given current of SC for the uninsulated wires with copper (aluminum) cores is accordingly about 2.48 (1.40) kA/mm2, for wires (cables) with copper (aluminum) cores (shells) and PVC (R) with insulation – 1.85 (1.18) kA/mm2, and for wires (cables) with copper (aluminum) cores (shells) and PET insulation – 1.53 (0.99) kA/mm2. The influence on a choice in the on-board network of aircrafts of maximum permissible sections Sil of its CCP and accordingly maximum permissible amplitudes of current density δilm of current copper (aluminum) parts of its wires and cables of frequency f of AC in the on-board network of aircraft is determined, but duration of flow tkC (time of disconnecting) renders in the on-board network of aircrafts of emergency current of SC ik(t. For diminishing in the on-board power circuits of electrical equipment of aircrafts of maximum permissible sections Sil of the electric wires (cables) applied in them and accordingly providing of decline for different aircrafts of mass and overall indicators of their on-board CCP is needed in the on-boar networks of aircrafts along with the use of enhance frequency of f=400 Hz of AC to apply the fast-acting devices of their protecting from SC in course of time wearing-outs of ta<<100 ms. It isshown that application of enhance frequency of f=400 Hz of AC in the on-board networks of aircrafts as compared to its frequency of f=50 Hz results in the considerable increase (in four times) of fast-acting of devices of their protection from SC, operation of which is based on the air electric explosion of metallic wire. Originality. First for the on-board network of aircrafts with AC of frequency of f=400 Hz the maximum permissible sections Sil and amplitudes of current density δilm of SC are determined for the uninsulated wires and insulated wires (cables) with copper (aluminum) cores (shells), PVC, R and PET insulation. Practical value. Theobtained results will be used in the increase of thermal resistibility of CCP with copper (aluminum) cores (shells), PVC, R and PET insulation applied in the on-board electric networks of different aircrafts.