Trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies

Abstract Few investigations have evaluated the 3-dimensional (3D) accuracy of digital implant scans. The aim of this study was to evaluate the performance of 10 intraoral scanners (IOSs) (CEREC Omnicam, CEREC Primescan, CS 3600, DWIO, i500, iTero Element, PlanScan, Trios 2, Trios 3, and True Definit...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Ryan Jin Young Kim, Goran I. Benic, Ji-Man Park
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/830325d93b1643a7be8707241c1f96e5
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:830325d93b1643a7be8707241c1f96e5
record_format dspace
spelling oai:doaj.org-article:830325d93b1643a7be8707241c1f96e52021-12-02T13:24:37ZTrueness of ten intraoral scanners in determining the positions of simulated implant scan bodies10.1038/s41598-021-82218-z2045-2322https://doaj.org/article/830325d93b1643a7be8707241c1f96e52021-01-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-82218-zhttps://doaj.org/toc/2045-2322Abstract Few investigations have evaluated the 3-dimensional (3D) accuracy of digital implant scans. The aim of this study was to evaluate the performance of 10 intraoral scanners (IOSs) (CEREC Omnicam, CEREC Primescan, CS 3600, DWIO, i500, iTero Element, PlanScan, Trios 2, Trios 3, and True Definition) in obtaining the accurate positions of 6 cylinders simulating implant scan bodies. Digital scans of each IOS were compared with the reference dataset obtained by means of a coordinate measuring machine. Deviation from the actual positions of the 6 cylinders along the XYZ axes and the overall 3D deviation of the digital scan were calculated. The type of IOSs and position of simulated cylindrical scan bodies affected the magnitude and direction of deviations on trueness. The lowest amount of deviation was found at the cylinder next to the reference origin, while the highest deviation was evident at the contralateral side for all IOSs (p < 0.001). Among the tested IOSs, the CEREC Primescan and Trios 3 had the highest trueness followed by i500, Trios 2, and iTero Element, albeit not statistically significant (p > 0.05), and the DWIO and PlasScan had the lowest trueness in partially edentulous mandible digital implant scans (p < 0.001).Ryan Jin Young KimGoran I. BenicJi-Man ParkNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-9 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Ryan Jin Young Kim
Goran I. Benic
Ji-Man Park
Trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies
description Abstract Few investigations have evaluated the 3-dimensional (3D) accuracy of digital implant scans. The aim of this study was to evaluate the performance of 10 intraoral scanners (IOSs) (CEREC Omnicam, CEREC Primescan, CS 3600, DWIO, i500, iTero Element, PlanScan, Trios 2, Trios 3, and True Definition) in obtaining the accurate positions of 6 cylinders simulating implant scan bodies. Digital scans of each IOS were compared with the reference dataset obtained by means of a coordinate measuring machine. Deviation from the actual positions of the 6 cylinders along the XYZ axes and the overall 3D deviation of the digital scan were calculated. The type of IOSs and position of simulated cylindrical scan bodies affected the magnitude and direction of deviations on trueness. The lowest amount of deviation was found at the cylinder next to the reference origin, while the highest deviation was evident at the contralateral side for all IOSs (p < 0.001). Among the tested IOSs, the CEREC Primescan and Trios 3 had the highest trueness followed by i500, Trios 2, and iTero Element, albeit not statistically significant (p > 0.05), and the DWIO and PlasScan had the lowest trueness in partially edentulous mandible digital implant scans (p < 0.001).
format article
author Ryan Jin Young Kim
Goran I. Benic
Ji-Man Park
author_facet Ryan Jin Young Kim
Goran I. Benic
Ji-Man Park
author_sort Ryan Jin Young Kim
title Trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies
title_short Trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies
title_full Trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies
title_fullStr Trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies
title_full_unstemmed Trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies
title_sort trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/830325d93b1643a7be8707241c1f96e5
work_keys_str_mv AT ryanjinyoungkim truenessoftenintraoralscannersindeterminingthepositionsofsimulatedimplantscanbodies
AT goranibenic truenessoftenintraoralscannersindeterminingthepositionsofsimulatedimplantscanbodies
AT jimanpark truenessoftenintraoralscannersindeterminingthepositionsofsimulatedimplantscanbodies
_version_ 1718393042410405888