Trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies
Abstract Few investigations have evaluated the 3-dimensional (3D) accuracy of digital implant scans. The aim of this study was to evaluate the performance of 10 intraoral scanners (IOSs) (CEREC Omnicam, CEREC Primescan, CS 3600, DWIO, i500, iTero Element, PlanScan, Trios 2, Trios 3, and True Definit...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/830325d93b1643a7be8707241c1f96e5 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:830325d93b1643a7be8707241c1f96e5 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:830325d93b1643a7be8707241c1f96e52021-12-02T13:24:37ZTrueness of ten intraoral scanners in determining the positions of simulated implant scan bodies10.1038/s41598-021-82218-z2045-2322https://doaj.org/article/830325d93b1643a7be8707241c1f96e52021-01-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-82218-zhttps://doaj.org/toc/2045-2322Abstract Few investigations have evaluated the 3-dimensional (3D) accuracy of digital implant scans. The aim of this study was to evaluate the performance of 10 intraoral scanners (IOSs) (CEREC Omnicam, CEREC Primescan, CS 3600, DWIO, i500, iTero Element, PlanScan, Trios 2, Trios 3, and True Definition) in obtaining the accurate positions of 6 cylinders simulating implant scan bodies. Digital scans of each IOS were compared with the reference dataset obtained by means of a coordinate measuring machine. Deviation from the actual positions of the 6 cylinders along the XYZ axes and the overall 3D deviation of the digital scan were calculated. The type of IOSs and position of simulated cylindrical scan bodies affected the magnitude and direction of deviations on trueness. The lowest amount of deviation was found at the cylinder next to the reference origin, while the highest deviation was evident at the contralateral side for all IOSs (p < 0.001). Among the tested IOSs, the CEREC Primescan and Trios 3 had the highest trueness followed by i500, Trios 2, and iTero Element, albeit not statistically significant (p > 0.05), and the DWIO and PlasScan had the lowest trueness in partially edentulous mandible digital implant scans (p < 0.001).Ryan Jin Young KimGoran I. BenicJi-Man ParkNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-9 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Ryan Jin Young Kim Goran I. Benic Ji-Man Park Trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies |
description |
Abstract Few investigations have evaluated the 3-dimensional (3D) accuracy of digital implant scans. The aim of this study was to evaluate the performance of 10 intraoral scanners (IOSs) (CEREC Omnicam, CEREC Primescan, CS 3600, DWIO, i500, iTero Element, PlanScan, Trios 2, Trios 3, and True Definition) in obtaining the accurate positions of 6 cylinders simulating implant scan bodies. Digital scans of each IOS were compared with the reference dataset obtained by means of a coordinate measuring machine. Deviation from the actual positions of the 6 cylinders along the XYZ axes and the overall 3D deviation of the digital scan were calculated. The type of IOSs and position of simulated cylindrical scan bodies affected the magnitude and direction of deviations on trueness. The lowest amount of deviation was found at the cylinder next to the reference origin, while the highest deviation was evident at the contralateral side for all IOSs (p < 0.001). Among the tested IOSs, the CEREC Primescan and Trios 3 had the highest trueness followed by i500, Trios 2, and iTero Element, albeit not statistically significant (p > 0.05), and the DWIO and PlasScan had the lowest trueness in partially edentulous mandible digital implant scans (p < 0.001). |
format |
article |
author |
Ryan Jin Young Kim Goran I. Benic Ji-Man Park |
author_facet |
Ryan Jin Young Kim Goran I. Benic Ji-Man Park |
author_sort |
Ryan Jin Young Kim |
title |
Trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies |
title_short |
Trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies |
title_full |
Trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies |
title_fullStr |
Trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies |
title_full_unstemmed |
Trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies |
title_sort |
trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies |
publisher |
Nature Portfolio |
publishDate |
2021 |
url |
https://doaj.org/article/830325d93b1643a7be8707241c1f96e5 |
work_keys_str_mv |
AT ryanjinyoungkim truenessoftenintraoralscannersindeterminingthepositionsofsimulatedimplantscanbodies AT goranibenic truenessoftenintraoralscannersindeterminingthepositionsofsimulatedimplantscanbodies AT jimanpark truenessoftenintraoralscannersindeterminingthepositionsofsimulatedimplantscanbodies |
_version_ |
1718393042410405888 |