An accurate fault location method for distribution network based on active transfer arc-suppression device

Active transfer arc-suppression device is a kind of arc suppression device which has been widely used in the distribution network. When a single-phase grounding fault occurs, the bus of faulty phase is actively grounded metallicity in the substation to limit the voltage of faulty phase, so as to rea...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Jian Qiao, Xianggen Yin, Yikai Wang, Wen Xu, Liming Tan
Formato: article
Lenguaje:EN
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://doaj.org/article/833280b29d9340dbb23bb990ac6c274a
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:833280b29d9340dbb23bb990ac6c274a
record_format dspace
spelling oai:doaj.org-article:833280b29d9340dbb23bb990ac6c274a2021-11-26T04:32:13ZAn accurate fault location method for distribution network based on active transfer arc-suppression device2352-484710.1016/j.egyr.2021.08.006https://doaj.org/article/833280b29d9340dbb23bb990ac6c274a2021-11-01T00:00:00Zhttp://www.sciencedirect.com/science/article/pii/S2352484721006077https://doaj.org/toc/2352-4847Active transfer arc-suppression device is a kind of arc suppression device which has been widely used in the distribution network. When a single-phase grounding fault occurs, the bus of faulty phase is actively grounded metallicity in the substation to limit the voltage of faulty phase, so as to realize arc extinction. In this paper, an accurate fault location method is proposed for the distribution network equipped with active transfer arc-suppression device. According to the variation characteristics of the fault traveling wave signals before and after arc-suppression device operation, the fault location formula based on the traveling wave velocity difference of different modes and the fault location formula based on the mutation of aerial-mode traveling wave are combined to obtain the final fault location method that is not affected by ground-mode wave velocity. The proposed method expands the function of active transfer arc-suppression device, makes it have additional fault location ability, and greatly improves the economy of the device. Simulation verifies that the proposed method is not affected by fault conditions, soil resistivity and extreme fault. The absolute error is within 50 m in all cases, which has high reliability.Jian QiaoXianggen YinYikai WangWen XuLiming TanElsevierarticleDistribution networkActive transfer arc-suppression deviceFault locationTraveling waveElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENEnergy Reports, Vol 7, Iss , Pp 552-560 (2021)
institution DOAJ
collection DOAJ
language EN
topic Distribution network
Active transfer arc-suppression device
Fault location
Traveling wave
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
spellingShingle Distribution network
Active transfer arc-suppression device
Fault location
Traveling wave
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
Jian Qiao
Xianggen Yin
Yikai Wang
Wen Xu
Liming Tan
An accurate fault location method for distribution network based on active transfer arc-suppression device
description Active transfer arc-suppression device is a kind of arc suppression device which has been widely used in the distribution network. When a single-phase grounding fault occurs, the bus of faulty phase is actively grounded metallicity in the substation to limit the voltage of faulty phase, so as to realize arc extinction. In this paper, an accurate fault location method is proposed for the distribution network equipped with active transfer arc-suppression device. According to the variation characteristics of the fault traveling wave signals before and after arc-suppression device operation, the fault location formula based on the traveling wave velocity difference of different modes and the fault location formula based on the mutation of aerial-mode traveling wave are combined to obtain the final fault location method that is not affected by ground-mode wave velocity. The proposed method expands the function of active transfer arc-suppression device, makes it have additional fault location ability, and greatly improves the economy of the device. Simulation verifies that the proposed method is not affected by fault conditions, soil resistivity and extreme fault. The absolute error is within 50 m in all cases, which has high reliability.
format article
author Jian Qiao
Xianggen Yin
Yikai Wang
Wen Xu
Liming Tan
author_facet Jian Qiao
Xianggen Yin
Yikai Wang
Wen Xu
Liming Tan
author_sort Jian Qiao
title An accurate fault location method for distribution network based on active transfer arc-suppression device
title_short An accurate fault location method for distribution network based on active transfer arc-suppression device
title_full An accurate fault location method for distribution network based on active transfer arc-suppression device
title_fullStr An accurate fault location method for distribution network based on active transfer arc-suppression device
title_full_unstemmed An accurate fault location method for distribution network based on active transfer arc-suppression device
title_sort accurate fault location method for distribution network based on active transfer arc-suppression device
publisher Elsevier
publishDate 2021
url https://doaj.org/article/833280b29d9340dbb23bb990ac6c274a
work_keys_str_mv AT jianqiao anaccuratefaultlocationmethodfordistributionnetworkbasedonactivetransferarcsuppressiondevice
AT xianggenyin anaccuratefaultlocationmethodfordistributionnetworkbasedonactivetransferarcsuppressiondevice
AT yikaiwang anaccuratefaultlocationmethodfordistributionnetworkbasedonactivetransferarcsuppressiondevice
AT wenxu anaccuratefaultlocationmethodfordistributionnetworkbasedonactivetransferarcsuppressiondevice
AT limingtan anaccuratefaultlocationmethodfordistributionnetworkbasedonactivetransferarcsuppressiondevice
AT jianqiao accuratefaultlocationmethodfordistributionnetworkbasedonactivetransferarcsuppressiondevice
AT xianggenyin accuratefaultlocationmethodfordistributionnetworkbasedonactivetransferarcsuppressiondevice
AT yikaiwang accuratefaultlocationmethodfordistributionnetworkbasedonactivetransferarcsuppressiondevice
AT wenxu accuratefaultlocationmethodfordistributionnetworkbasedonactivetransferarcsuppressiondevice
AT limingtan accuratefaultlocationmethodfordistributionnetworkbasedonactivetransferarcsuppressiondevice
_version_ 1718409850783793152