Timepix3 detector network for nuclear waste monitoring

In the framework of the MICADO project we proposed an active long-term nuclear waste monitoring system based on Timepix3 technology. Particle detectors based on Timepix3 are capable of particle type discrimination and provide spectrometric information in combination with precise timing information....

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Biskup Bartolomej, Bergmann Benedikt, Broulim Pavel, Burian Petr, Malich Milan, Manek Petr, Meduna Lukas, Mora Yesid, Pichotka Martin, Pusman Lukas, Rubovic Peter, Slavicek Tomas, Smolyanskiy Petr
Formato: article
Lenguaje:EN
Publicado: EDP Sciences 2021
Materias:
Acceso en línea:https://doaj.org/article/8332d38907af48f5a2deb8e711dd9f2d
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:8332d38907af48f5a2deb8e711dd9f2d
record_format dspace
spelling oai:doaj.org-article:8332d38907af48f5a2deb8e711dd9f2d2021-12-02T17:12:46ZTimepix3 detector network for nuclear waste monitoring2100-014X10.1051/epjconf/202125307010https://doaj.org/article/8332d38907af48f5a2deb8e711dd9f2d2021-01-01T00:00:00Zhttps://www.epj-conferences.org/articles/epjconf/pdf/2021/07/epjconf_animma2021_07010.pdfhttps://doaj.org/toc/2100-014XIn the framework of the MICADO project we proposed an active long-term nuclear waste monitoring system based on Timepix3 technology. Particle detectors based on Timepix3 are capable of particle type discrimination and provide spectrometric information in combination with precise timing information. To maximize the versatility of the setup, the Timepix3 detectors employed are equipped with a range of different sensors. To enable measurement of neutrons, two quadrants of the detectors are covered by neutron converters, allowing detection of thermal neutron by capture in 6Li, as well as detection of fast neutrons through recoil protons generated in a polyethylene converter. Within this project a new housing for the detector unit and the readout was developed, with the network currently comprising of 9 such detectors. A specifically developed in-house software handles simultaneous operation of all devices, cluster analysis and data visualization. Energy calibration was performed using an X-ray tube with several fluorescence foils as well as photons from an 241Am source. The neutron and gamma/X-ray detection efficiency calibration was carried out at the Czech Metrology Institute and the results are presented here. Tests on simultaneous operation of all 9 devices were performed using uraninite and 241Am sources.Biskup BartolomejBergmann BenediktBroulim PavelBurian PetrMalich MilanManek PetrMeduna LukasMora YesidPichotka MartinPusman LukasRubovic PeterSlavicek TomasSmolyanskiy PetrEDP Sciencesarticletimepix3 detectornuclear waste monitoringneutron detectionPhysicsQC1-999ENEPJ Web of Conferences, Vol 253, p 07010 (2021)
institution DOAJ
collection DOAJ
language EN
topic timepix3 detector
nuclear waste monitoring
neutron detection
Physics
QC1-999
spellingShingle timepix3 detector
nuclear waste monitoring
neutron detection
Physics
QC1-999
Biskup Bartolomej
Bergmann Benedikt
Broulim Pavel
Burian Petr
Malich Milan
Manek Petr
Meduna Lukas
Mora Yesid
Pichotka Martin
Pusman Lukas
Rubovic Peter
Slavicek Tomas
Smolyanskiy Petr
Timepix3 detector network for nuclear waste monitoring
description In the framework of the MICADO project we proposed an active long-term nuclear waste monitoring system based on Timepix3 technology. Particle detectors based on Timepix3 are capable of particle type discrimination and provide spectrometric information in combination with precise timing information. To maximize the versatility of the setup, the Timepix3 detectors employed are equipped with a range of different sensors. To enable measurement of neutrons, two quadrants of the detectors are covered by neutron converters, allowing detection of thermal neutron by capture in 6Li, as well as detection of fast neutrons through recoil protons generated in a polyethylene converter. Within this project a new housing for the detector unit and the readout was developed, with the network currently comprising of 9 such detectors. A specifically developed in-house software handles simultaneous operation of all devices, cluster analysis and data visualization. Energy calibration was performed using an X-ray tube with several fluorescence foils as well as photons from an 241Am source. The neutron and gamma/X-ray detection efficiency calibration was carried out at the Czech Metrology Institute and the results are presented here. Tests on simultaneous operation of all 9 devices were performed using uraninite and 241Am sources.
format article
author Biskup Bartolomej
Bergmann Benedikt
Broulim Pavel
Burian Petr
Malich Milan
Manek Petr
Meduna Lukas
Mora Yesid
Pichotka Martin
Pusman Lukas
Rubovic Peter
Slavicek Tomas
Smolyanskiy Petr
author_facet Biskup Bartolomej
Bergmann Benedikt
Broulim Pavel
Burian Petr
Malich Milan
Manek Petr
Meduna Lukas
Mora Yesid
Pichotka Martin
Pusman Lukas
Rubovic Peter
Slavicek Tomas
Smolyanskiy Petr
author_sort Biskup Bartolomej
title Timepix3 detector network for nuclear waste monitoring
title_short Timepix3 detector network for nuclear waste monitoring
title_full Timepix3 detector network for nuclear waste monitoring
title_fullStr Timepix3 detector network for nuclear waste monitoring
title_full_unstemmed Timepix3 detector network for nuclear waste monitoring
title_sort timepix3 detector network for nuclear waste monitoring
publisher EDP Sciences
publishDate 2021
url https://doaj.org/article/8332d38907af48f5a2deb8e711dd9f2d
work_keys_str_mv AT biskupbartolomej timepix3detectornetworkfornuclearwastemonitoring
AT bergmannbenedikt timepix3detectornetworkfornuclearwastemonitoring
AT broulimpavel timepix3detectornetworkfornuclearwastemonitoring
AT burianpetr timepix3detectornetworkfornuclearwastemonitoring
AT malichmilan timepix3detectornetworkfornuclearwastemonitoring
AT manekpetr timepix3detectornetworkfornuclearwastemonitoring
AT medunalukas timepix3detectornetworkfornuclearwastemonitoring
AT morayesid timepix3detectornetworkfornuclearwastemonitoring
AT pichotkamartin timepix3detectornetworkfornuclearwastemonitoring
AT pusmanlukas timepix3detectornetworkfornuclearwastemonitoring
AT rubovicpeter timepix3detectornetworkfornuclearwastemonitoring
AT slavicektomas timepix3detectornetworkfornuclearwastemonitoring
AT smolyanskiypetr timepix3detectornetworkfornuclearwastemonitoring
_version_ 1718381389013843968