Three bedside techniques to quantify dynamic pulmonary hyperinflation in mechanically ventilated patients with chronic obstructive pulmonary disease
Abstract Background Dynamic pulmonary hyperinflation may develop in patients with chronic obstructive pulmonary disease (COPD) due to dynamic airway collapse and/or increased airway resistance, increasing the risk of volutrauma and hemodynamic compromise. The reference standard to quantify dynamic p...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
SpringerOpen
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/83489668ad8847dc90890f038f92e944 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
Sumario: | Abstract Background Dynamic pulmonary hyperinflation may develop in patients with chronic obstructive pulmonary disease (COPD) due to dynamic airway collapse and/or increased airway resistance, increasing the risk of volutrauma and hemodynamic compromise. The reference standard to quantify dynamic pulmonary hyperinflation is the measurement of the volume at end-inspiration (Vei). As this is cumbersome, the aim of this study was to evaluate if methods that are easier to perform at the bedside can accurately reflect Vei. Methods Vei was assessed in COPD patients under controlled protective mechanical ventilation (7 ± mL/kg) on zero end-expiratory pressure, using three techniques in a fixed order: (1) reference standard (Veireference): passive exhalation to atmosphere from end-inspiration in a calibrated glass burette; (2) ventilator maneuver (Veimaneuver): measuring the expired volume during a passive exhalation of 45s using the ventilator flow sensor; (3) formula (Veiformula): (Vt × P plateau)/(P plateau − PEEPi), with Vt tidal volume, P plateau is plateau pressure after an end-inspiratory occlusion, and PEEPi is intrinsic positive end-expiratory pressure after an end-expiratory occlusion. A convenience sample of 17 patients was recruited. Results Veireference was 1030 ± 380 mL and had no significant correlation with P plateau (r 2 = 0.06; P = 0.3710) or PEEPi (r 2 = 0.11; P = 0.2156), and was inversely related with P drive (calculated as P plateau −PEEPi) (r 2 = 0.49; P = 0.0024). A low bias but rather wide limits of agreement and fairly good correlations were found when comparing Veimaneuver and Veiformula to Veireference. Vei remained stable during the study period (low bias 15 mL with high agreement (95% limits of agreement from − 100 to 130 mL) and high correlation (r 2 = 0.98; P < 0.0001) between both measurements of Veireference). Conclusions In patients with COPD, airway pressures are not a valid representation of Vei. The three techniques to quantify Vei show low bias, but wide limits of agreement. |
---|