Test-retest reproducibility of in vivo oscillating gradient and microscopic anisotropy diffusion MRI in mice at 9.4 Tesla.

<h4>Background and purpose</h4>Microstructure imaging with advanced diffusion MRI (dMRI) techniques have shown increased sensitivity and specificity to microstructural changes in various disease and injury models. Oscillating gradient spin echo (OGSE) dMRI, implemented by varying the osc...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Naila Rahman, Kathy Xu, Mohammad Omer, Matthew D Budde, Arthur Brown, Corey A Baron
Formato: article
Lenguaje:EN
Publicado: Public Library of Science (PLoS) 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/83c06e3472ff4337899076cc1ced486e
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:83c06e3472ff4337899076cc1ced486e
record_format dspace
spelling oai:doaj.org-article:83c06e3472ff4337899076cc1ced486e2021-12-02T20:06:05ZTest-retest reproducibility of in vivo oscillating gradient and microscopic anisotropy diffusion MRI in mice at 9.4 Tesla.1932-620310.1371/journal.pone.0255711https://doaj.org/article/83c06e3472ff4337899076cc1ced486e2021-01-01T00:00:00Zhttps://doi.org/10.1371/journal.pone.0255711https://doaj.org/toc/1932-6203<h4>Background and purpose</h4>Microstructure imaging with advanced diffusion MRI (dMRI) techniques have shown increased sensitivity and specificity to microstructural changes in various disease and injury models. Oscillating gradient spin echo (OGSE) dMRI, implemented by varying the oscillating gradient frequency, and microscopic anisotropy (μA) dMRI, implemented via tensor valued diffusion encoding, may provide additional insight by increasing sensitivity to smaller spatial scales and disentangling fiber orientation dispersion from true microstructural changes, respectively. The aims of this study were to characterize the test-retest reproducibility of in vivo OGSE and μA dMRI metrics in the mouse brain at 9.4 Tesla and provide estimates of required sample sizes for future investigations.<h4>Methods</h4>Twelve adult C57Bl/6 mice were scanned twice (5 days apart). Each imaging session consisted of multifrequency OGSE and μA dMRI protocols. Metrics investigated included μA, linear diffusion kurtosis, isotropic diffusion kurtosis, and the diffusion dispersion rate (Λ), which explores the power-law frequency dependence of mean diffusivity. The dMRI metric maps were analyzed with mean region-of-interest (ROI) and whole brain voxel-wise analysis. Bland-Altman plots and coefficients of variation (CV) were used to assess the reproducibility of OGSE and μA metrics. Furthermore, we estimated sample sizes required to detect a variety of effect sizes.<h4>Results</h4>Bland-Altman plots showed negligible biases between test and retest sessions. ROI-based CVs revealed high reproducibility for most metrics (CVs < 15%). Voxel-wise CV maps revealed high reproducibility for μA (CVs ~ 10%), but low reproducibility for OGSE metrics (CVs ~ 50%).<h4>Conclusion</h4>Most of the μA dMRI metrics are reproducible in both ROI-based and voxel-wise analysis, while the OGSE dMRI metrics are only reproducible in ROI-based analysis. Given feasible sample sizes (10-15), μA metrics and OGSE metrics may provide sensitivity to subtle microstructural changes (4-8%) and moderate changes (> 6%), respectively.Naila RahmanKathy XuMohammad OmerMatthew D BuddeArthur BrownCorey A BaronPublic Library of Science (PLoS)articleMedicineRScienceQENPLoS ONE, Vol 16, Iss 11, p e0255711 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Naila Rahman
Kathy Xu
Mohammad Omer
Matthew D Budde
Arthur Brown
Corey A Baron
Test-retest reproducibility of in vivo oscillating gradient and microscopic anisotropy diffusion MRI in mice at 9.4 Tesla.
description <h4>Background and purpose</h4>Microstructure imaging with advanced diffusion MRI (dMRI) techniques have shown increased sensitivity and specificity to microstructural changes in various disease and injury models. Oscillating gradient spin echo (OGSE) dMRI, implemented by varying the oscillating gradient frequency, and microscopic anisotropy (μA) dMRI, implemented via tensor valued diffusion encoding, may provide additional insight by increasing sensitivity to smaller spatial scales and disentangling fiber orientation dispersion from true microstructural changes, respectively. The aims of this study were to characterize the test-retest reproducibility of in vivo OGSE and μA dMRI metrics in the mouse brain at 9.4 Tesla and provide estimates of required sample sizes for future investigations.<h4>Methods</h4>Twelve adult C57Bl/6 mice were scanned twice (5 days apart). Each imaging session consisted of multifrequency OGSE and μA dMRI protocols. Metrics investigated included μA, linear diffusion kurtosis, isotropic diffusion kurtosis, and the diffusion dispersion rate (Λ), which explores the power-law frequency dependence of mean diffusivity. The dMRI metric maps were analyzed with mean region-of-interest (ROI) and whole brain voxel-wise analysis. Bland-Altman plots and coefficients of variation (CV) were used to assess the reproducibility of OGSE and μA metrics. Furthermore, we estimated sample sizes required to detect a variety of effect sizes.<h4>Results</h4>Bland-Altman plots showed negligible biases between test and retest sessions. ROI-based CVs revealed high reproducibility for most metrics (CVs < 15%). Voxel-wise CV maps revealed high reproducibility for μA (CVs ~ 10%), but low reproducibility for OGSE metrics (CVs ~ 50%).<h4>Conclusion</h4>Most of the μA dMRI metrics are reproducible in both ROI-based and voxel-wise analysis, while the OGSE dMRI metrics are only reproducible in ROI-based analysis. Given feasible sample sizes (10-15), μA metrics and OGSE metrics may provide sensitivity to subtle microstructural changes (4-8%) and moderate changes (> 6%), respectively.
format article
author Naila Rahman
Kathy Xu
Mohammad Omer
Matthew D Budde
Arthur Brown
Corey A Baron
author_facet Naila Rahman
Kathy Xu
Mohammad Omer
Matthew D Budde
Arthur Brown
Corey A Baron
author_sort Naila Rahman
title Test-retest reproducibility of in vivo oscillating gradient and microscopic anisotropy diffusion MRI in mice at 9.4 Tesla.
title_short Test-retest reproducibility of in vivo oscillating gradient and microscopic anisotropy diffusion MRI in mice at 9.4 Tesla.
title_full Test-retest reproducibility of in vivo oscillating gradient and microscopic anisotropy diffusion MRI in mice at 9.4 Tesla.
title_fullStr Test-retest reproducibility of in vivo oscillating gradient and microscopic anisotropy diffusion MRI in mice at 9.4 Tesla.
title_full_unstemmed Test-retest reproducibility of in vivo oscillating gradient and microscopic anisotropy diffusion MRI in mice at 9.4 Tesla.
title_sort test-retest reproducibility of in vivo oscillating gradient and microscopic anisotropy diffusion mri in mice at 9.4 tesla.
publisher Public Library of Science (PLoS)
publishDate 2021
url https://doaj.org/article/83c06e3472ff4337899076cc1ced486e
work_keys_str_mv AT nailarahman testretestreproducibilityofinvivooscillatinggradientandmicroscopicanisotropydiffusionmriinmiceat94tesla
AT kathyxu testretestreproducibilityofinvivooscillatinggradientandmicroscopicanisotropydiffusionmriinmiceat94tesla
AT mohammadomer testretestreproducibilityofinvivooscillatinggradientandmicroscopicanisotropydiffusionmriinmiceat94tesla
AT matthewdbudde testretestreproducibilityofinvivooscillatinggradientandmicroscopicanisotropydiffusionmriinmiceat94tesla
AT arthurbrown testretestreproducibilityofinvivooscillatinggradientandmicroscopicanisotropydiffusionmriinmiceat94tesla
AT coreyabaron testretestreproducibilityofinvivooscillatinggradientandmicroscopicanisotropydiffusionmriinmiceat94tesla
_version_ 1718375436580290560