Stationary tissue background correction increases the precision of clinical evaluation of intra-cardiac shunts by cardiovascular magnetic resonance
Abstract We aimed to evaluate the clinical utility of stationary tissue background phase correction for affecting precision in the measurement of Qp/Qs by cardiovascular magnetic resonance (CMR). We enrolled consecutive patients (n = 91) referred for CMR at 1.5T without suspicion of cardiac shunt, a...
Guardado en:
Autores principales: | , , , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2020
|
Materias: | |
Acceso en línea: | https://doaj.org/article/845598bad5be4c399e799204fdc72d29 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:845598bad5be4c399e799204fdc72d29 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:845598bad5be4c399e799204fdc72d292021-12-02T17:05:01ZStationary tissue background correction increases the precision of clinical evaluation of intra-cardiac shunts by cardiovascular magnetic resonance10.1038/s41598-020-61812-72045-2322https://doaj.org/article/845598bad5be4c399e799204fdc72d292020-03-01T00:00:00Zhttps://doi.org/10.1038/s41598-020-61812-7https://doaj.org/toc/2045-2322Abstract We aimed to evaluate the clinical utility of stationary tissue background phase correction for affecting precision in the measurement of Qp/Qs by cardiovascular magnetic resonance (CMR). We enrolled consecutive patients (n = 91) referred for CMR at 1.5T without suspicion of cardiac shunt, and patients (n = 10) with verified cardiac shunts in this retrospective study. All patients underwent phase contrast flow quantification in the ascending aorta and pulmonary trunk. Flow was quantified using two semi-automatic software platforms (SyngoVia VA30, Vendor 1; Segment 2.0R4534, Vendor 2). Measurements were performed both uncorrected and corrected for linear (Vendor 1 and Vendor 2) or quadratic (Vendor 2) background phase. The proportion of patients outside the normal range of Qp/Qs was compared using the McNemar’s test. Compared to uncorrected measurements, there were fewer patients with a Qp/Qs outside the normal range following linear correction using Vendor 1 (10% vs 18%, p < 0.001), and Vendor 2 (10% vs 18%, p < 0.001), and following quadratic correction using Vendor 2 (7% vs 18%, p < 0.001). No patient with known shunt was reclassified as normal following stationary background correction. Therefore, we conclude that stationary tissue background correction reduces the number of patients with a Qp/Qs ratio outside the normal range in a consecutive clinical population, while simultaneously not reclassifying any patient with known cardiac shunts as having a normal Qp/Qs. Stationary tissue background correction may be used in clinical patients to increase diagnostic precision.Jannike NickanderMagnus LundinGoran AbdulaJonas JennerEva MaretPeder SörenssonEinar HeibergAndreas SigfridssonMartin UganderNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 10, Iss 1, Pp 1-8 (2020) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Jannike Nickander Magnus Lundin Goran Abdula Jonas Jenner Eva Maret Peder Sörensson Einar Heiberg Andreas Sigfridsson Martin Ugander Stationary tissue background correction increases the precision of clinical evaluation of intra-cardiac shunts by cardiovascular magnetic resonance |
description |
Abstract We aimed to evaluate the clinical utility of stationary tissue background phase correction for affecting precision in the measurement of Qp/Qs by cardiovascular magnetic resonance (CMR). We enrolled consecutive patients (n = 91) referred for CMR at 1.5T without suspicion of cardiac shunt, and patients (n = 10) with verified cardiac shunts in this retrospective study. All patients underwent phase contrast flow quantification in the ascending aorta and pulmonary trunk. Flow was quantified using two semi-automatic software platforms (SyngoVia VA30, Vendor 1; Segment 2.0R4534, Vendor 2). Measurements were performed both uncorrected and corrected for linear (Vendor 1 and Vendor 2) or quadratic (Vendor 2) background phase. The proportion of patients outside the normal range of Qp/Qs was compared using the McNemar’s test. Compared to uncorrected measurements, there were fewer patients with a Qp/Qs outside the normal range following linear correction using Vendor 1 (10% vs 18%, p < 0.001), and Vendor 2 (10% vs 18%, p < 0.001), and following quadratic correction using Vendor 2 (7% vs 18%, p < 0.001). No patient with known shunt was reclassified as normal following stationary background correction. Therefore, we conclude that stationary tissue background correction reduces the number of patients with a Qp/Qs ratio outside the normal range in a consecutive clinical population, while simultaneously not reclassifying any patient with known cardiac shunts as having a normal Qp/Qs. Stationary tissue background correction may be used in clinical patients to increase diagnostic precision. |
format |
article |
author |
Jannike Nickander Magnus Lundin Goran Abdula Jonas Jenner Eva Maret Peder Sörensson Einar Heiberg Andreas Sigfridsson Martin Ugander |
author_facet |
Jannike Nickander Magnus Lundin Goran Abdula Jonas Jenner Eva Maret Peder Sörensson Einar Heiberg Andreas Sigfridsson Martin Ugander |
author_sort |
Jannike Nickander |
title |
Stationary tissue background correction increases the precision of clinical evaluation of intra-cardiac shunts by cardiovascular magnetic resonance |
title_short |
Stationary tissue background correction increases the precision of clinical evaluation of intra-cardiac shunts by cardiovascular magnetic resonance |
title_full |
Stationary tissue background correction increases the precision of clinical evaluation of intra-cardiac shunts by cardiovascular magnetic resonance |
title_fullStr |
Stationary tissue background correction increases the precision of clinical evaluation of intra-cardiac shunts by cardiovascular magnetic resonance |
title_full_unstemmed |
Stationary tissue background correction increases the precision of clinical evaluation of intra-cardiac shunts by cardiovascular magnetic resonance |
title_sort |
stationary tissue background correction increases the precision of clinical evaluation of intra-cardiac shunts by cardiovascular magnetic resonance |
publisher |
Nature Portfolio |
publishDate |
2020 |
url |
https://doaj.org/article/845598bad5be4c399e799204fdc72d29 |
work_keys_str_mv |
AT jannikenickander stationarytissuebackgroundcorrectionincreasestheprecisionofclinicalevaluationofintracardiacshuntsbycardiovascularmagneticresonance AT magnuslundin stationarytissuebackgroundcorrectionincreasestheprecisionofclinicalevaluationofintracardiacshuntsbycardiovascularmagneticresonance AT goranabdula stationarytissuebackgroundcorrectionincreasestheprecisionofclinicalevaluationofintracardiacshuntsbycardiovascularmagneticresonance AT jonasjenner stationarytissuebackgroundcorrectionincreasestheprecisionofclinicalevaluationofintracardiacshuntsbycardiovascularmagneticresonance AT evamaret stationarytissuebackgroundcorrectionincreasestheprecisionofclinicalevaluationofintracardiacshuntsbycardiovascularmagneticresonance AT pedersorensson stationarytissuebackgroundcorrectionincreasestheprecisionofclinicalevaluationofintracardiacshuntsbycardiovascularmagneticresonance AT einarheiberg stationarytissuebackgroundcorrectionincreasestheprecisionofclinicalevaluationofintracardiacshuntsbycardiovascularmagneticresonance AT andreassigfridsson stationarytissuebackgroundcorrectionincreasestheprecisionofclinicalevaluationofintracardiacshuntsbycardiovascularmagneticresonance AT martinugander stationarytissuebackgroundcorrectionincreasestheprecisionofclinicalevaluationofintracardiacshuntsbycardiovascularmagneticresonance |
_version_ |
1718381799368818688 |