A millimetric ruler for Lester Jones tube placement in conjunctivodacryocystorhinostomy
Rodolfo Luis Vigo, Tomás Ortiz-Basso, María Natalia Vilas, Jorge PrémoliOphthalmology Department, Hospital Italiano de Buenos Aires, Buenos Aires, Argentina Purpose: To describe the use of a ruler to increase the accuracy and customization of Lester Jones tube placem...
Guardado en:
Autores principales: | , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2015
|
Materias: | |
Acceso en línea: | https://doaj.org/article/845c762e875d42e295923993a4ae3240 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:845c762e875d42e295923993a4ae3240 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:845c762e875d42e295923993a4ae32402021-12-02T05:40:13ZA millimetric ruler for Lester Jones tube placement in conjunctivodacryocystorhinostomy1177-5483https://doaj.org/article/845c762e875d42e295923993a4ae32402015-08-01T00:00:00Zhttp://www.dovepress.com/a-millimetric-ruler-for-lester-jones-tube-placement-in-conjunctivodacr-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Rodolfo Luis Vigo, Tomás Ortiz-Basso, María Natalia Vilas, Jorge PrémoliOphthalmology Department, Hospital Italiano de Buenos Aires, Buenos Aires, Argentina Purpose: To describe the use of a ruler to increase the accuracy and customization of Lester Jones tube placement.Materials and methods: This was a review of 92 patients who underwent minimally invasive conjunctivodacryocystorhinostomy using this instrument.Results: The success rate was 100%, with an average operating time of 15 minutes. In nine patients, late migration of the Jones tube into the nasal cavity required a secondary intervention, with successful Jones tube repositioning. In five cases, obstruction of the tube opening was caused by conjunctival overgrowth.Conclusion: The millimetric ruler engraved in the sleeve of the trocar allows measuring and placing a personalized tube for each patient. Keywords: lacrimal apparatus, lacrimal apparatus diseases, lacrimal duct obstruction, dacryocystorhinostomy, surgical instrumentsVigo RLOrtiz-Basso TVilas MNPrémoli JDove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2015, Iss default, Pp 1523-1525 (2015) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Ophthalmology RE1-994 |
spellingShingle |
Ophthalmology RE1-994 Vigo RL Ortiz-Basso T Vilas MN Prémoli J A millimetric ruler for Lester Jones tube placement in conjunctivodacryocystorhinostomy |
description |
Rodolfo Luis Vigo, Tomás Ortiz-Basso, María Natalia Vilas, Jorge PrémoliOphthalmology Department, Hospital Italiano de Buenos Aires, Buenos Aires, Argentina Purpose: To describe the use of a ruler to increase the accuracy and customization of Lester Jones tube placement.Materials and methods: This was a review of 92 patients who underwent minimally invasive conjunctivodacryocystorhinostomy using this instrument.Results: The success rate was 100%, with an average operating time of 15 minutes. In nine patients, late migration of the Jones tube into the nasal cavity required a secondary intervention, with successful Jones tube repositioning. In five cases, obstruction of the tube opening was caused by conjunctival overgrowth.Conclusion: The millimetric ruler engraved in the sleeve of the trocar allows measuring and placing a personalized tube for each patient. Keywords: lacrimal apparatus, lacrimal apparatus diseases, lacrimal duct obstruction, dacryocystorhinostomy, surgical instruments |
format |
article |
author |
Vigo RL Ortiz-Basso T Vilas MN Prémoli J |
author_facet |
Vigo RL Ortiz-Basso T Vilas MN Prémoli J |
author_sort |
Vigo RL |
title |
A millimetric ruler for Lester Jones tube placement in conjunctivodacryocystorhinostomy |
title_short |
A millimetric ruler for Lester Jones tube placement in conjunctivodacryocystorhinostomy |
title_full |
A millimetric ruler for Lester Jones tube placement in conjunctivodacryocystorhinostomy |
title_fullStr |
A millimetric ruler for Lester Jones tube placement in conjunctivodacryocystorhinostomy |
title_full_unstemmed |
A millimetric ruler for Lester Jones tube placement in conjunctivodacryocystorhinostomy |
title_sort |
millimetric ruler for lester jones tube placement in conjunctivodacryocystorhinostomy |
publisher |
Dove Medical Press |
publishDate |
2015 |
url |
https://doaj.org/article/845c762e875d42e295923993a4ae3240 |
work_keys_str_mv |
AT vigorl amillimetricrulerforlesterjonestubeplacementinconjunctivodacryocystorhinostomy AT ortizbassot amillimetricrulerforlesterjonestubeplacementinconjunctivodacryocystorhinostomy AT vilasmn amillimetricrulerforlesterjonestubeplacementinconjunctivodacryocystorhinostomy AT premolij amillimetricrulerforlesterjonestubeplacementinconjunctivodacryocystorhinostomy AT vigorl millimetricrulerforlesterjonestubeplacementinconjunctivodacryocystorhinostomy AT ortizbassot millimetricrulerforlesterjonestubeplacementinconjunctivodacryocystorhinostomy AT vilasmn millimetricrulerforlesterjonestubeplacementinconjunctivodacryocystorhinostomy AT premolij millimetricrulerforlesterjonestubeplacementinconjunctivodacryocystorhinostomy |
_version_ |
1718400306480414720 |