Synthesis of constructive-technological decisions of regulation of working capacitance of cables of industrial networks

Introduction. Over the past 10 years, the number of industrial networks has more than doubled. At the physical level, all industrial technology networks are based on twisted pair. Purpose. Synthesis of constructive-technological decisions of regulation of electric capacitance of the insulated conduc...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: G.V. Bezprozvannych, I.A. Kostiukov, O.A. Pushkar
Formato: article
Lenguaje:EN
RU
UK
Publicado: National Technical University "Kharkiv Polytechnic Institute" 2021
Materias:
Acceso en línea:https://doaj.org/article/84c5a8424bc7442a8a8dd3583c7cf153
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:84c5a8424bc7442a8a8dd3583c7cf153
record_format dspace
spelling oai:doaj.org-article:84c5a8424bc7442a8a8dd3583c7cf1532021-12-02T18:42:19ZSynthesis of constructive-technological decisions of regulation of working capacitance of cables of industrial networks10.20998/2074-272X.2021.1.072074-272X2309-3404https://doaj.org/article/84c5a8424bc7442a8a8dd3583c7cf1532021-02-01T00:00:00Zhttp://eie.khpi.edu.ua/article/view/225161/225157https://doaj.org/toc/2074-272Xhttps://doaj.org/toc/2309-3404Introduction. Over the past 10 years, the number of industrial networks has more than doubled. At the physical level, all industrial technology networks are based on twisted pair. Purpose. Synthesis of constructive-technological decisions of regulation of electric capacitance of the insulated conductor at a stage of manufacturing of twisted pair of cables of industrial networks. Methodology. The method of secondary charges to determine the capacitance of the insulated conductor by varying the thickness of the solid and foamed polyethylene insulation. Practical value. Effective regulation is provided on the basis of the obtained dependencies of the effective dielectric constant, the tangent of the dielectric loss angle and the capacitance of the insulated conductor on the degree of foaming and the thickness of the protective film of two-layer insulation. At a degree of porosity of 40 %, the dielectric constant decreases by 25 %, the tangent of the dielectric loss angle – by 33 %, the electrical capacitance of the insulated conductor – by 20 %.G.V. BezprozvannychI.A. KostiukovO.A. PushkarNational Technical University "Kharkiv Polytechnic Institute"articleindustrial networkstwisted pairinsulated conductorfoaminginsulation thicknesseffective dielectric constantelectrical capacitanceElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENRUUKElectrical engineering & Electromechanics, Iss 1, Pp 44-49 (2021)
institution DOAJ
collection DOAJ
language EN
RU
UK
topic industrial networks
twisted pair
insulated conductor
foaming
insulation thickness
effective dielectric constant
electrical capacitance
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
spellingShingle industrial networks
twisted pair
insulated conductor
foaming
insulation thickness
effective dielectric constant
electrical capacitance
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
G.V. Bezprozvannych
I.A. Kostiukov
O.A. Pushkar
Synthesis of constructive-technological decisions of regulation of working capacitance of cables of industrial networks
description Introduction. Over the past 10 years, the number of industrial networks has more than doubled. At the physical level, all industrial technology networks are based on twisted pair. Purpose. Synthesis of constructive-technological decisions of regulation of electric capacitance of the insulated conductor at a stage of manufacturing of twisted pair of cables of industrial networks. Methodology. The method of secondary charges to determine the capacitance of the insulated conductor by varying the thickness of the solid and foamed polyethylene insulation. Practical value. Effective regulation is provided on the basis of the obtained dependencies of the effective dielectric constant, the tangent of the dielectric loss angle and the capacitance of the insulated conductor on the degree of foaming and the thickness of the protective film of two-layer insulation. At a degree of porosity of 40 %, the dielectric constant decreases by 25 %, the tangent of the dielectric loss angle – by 33 %, the electrical capacitance of the insulated conductor – by 20 %.
format article
author G.V. Bezprozvannych
I.A. Kostiukov
O.A. Pushkar
author_facet G.V. Bezprozvannych
I.A. Kostiukov
O.A. Pushkar
author_sort G.V. Bezprozvannych
title Synthesis of constructive-technological decisions of regulation of working capacitance of cables of industrial networks
title_short Synthesis of constructive-technological decisions of regulation of working capacitance of cables of industrial networks
title_full Synthesis of constructive-technological decisions of regulation of working capacitance of cables of industrial networks
title_fullStr Synthesis of constructive-technological decisions of regulation of working capacitance of cables of industrial networks
title_full_unstemmed Synthesis of constructive-technological decisions of regulation of working capacitance of cables of industrial networks
title_sort synthesis of constructive-technological decisions of regulation of working capacitance of cables of industrial networks
publisher National Technical University "Kharkiv Polytechnic Institute"
publishDate 2021
url https://doaj.org/article/84c5a8424bc7442a8a8dd3583c7cf153
work_keys_str_mv AT gvbezprozvannych synthesisofconstructivetechnologicaldecisionsofregulationofworkingcapacitanceofcablesofindustrialnetworks
AT iakostiukov synthesisofconstructivetechnologicaldecisionsofregulationofworkingcapacitanceofcablesofindustrialnetworks
AT oapushkar synthesisofconstructivetechnologicaldecisionsofregulationofworkingcapacitanceofcablesofindustrialnetworks
_version_ 1718377748096876544