Synthesis of constructive-technological decisions of regulation of working capacitance of cables of industrial networks
Introduction. Over the past 10 years, the number of industrial networks has more than doubled. At the physical level, all industrial technology networks are based on twisted pair. Purpose. Synthesis of constructive-technological decisions of regulation of electric capacitance of the insulated conduc...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | EN RU UK |
Publicado: |
National Technical University "Kharkiv Polytechnic Institute"
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/84c5a8424bc7442a8a8dd3583c7cf153 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:84c5a8424bc7442a8a8dd3583c7cf153 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:84c5a8424bc7442a8a8dd3583c7cf1532021-12-02T18:42:19ZSynthesis of constructive-technological decisions of regulation of working capacitance of cables of industrial networks10.20998/2074-272X.2021.1.072074-272X2309-3404https://doaj.org/article/84c5a8424bc7442a8a8dd3583c7cf1532021-02-01T00:00:00Zhttp://eie.khpi.edu.ua/article/view/225161/225157https://doaj.org/toc/2074-272Xhttps://doaj.org/toc/2309-3404Introduction. Over the past 10 years, the number of industrial networks has more than doubled. At the physical level, all industrial technology networks are based on twisted pair. Purpose. Synthesis of constructive-technological decisions of regulation of electric capacitance of the insulated conductor at a stage of manufacturing of twisted pair of cables of industrial networks. Methodology. The method of secondary charges to determine the capacitance of the insulated conductor by varying the thickness of the solid and foamed polyethylene insulation. Practical value. Effective regulation is provided on the basis of the obtained dependencies of the effective dielectric constant, the tangent of the dielectric loss angle and the capacitance of the insulated conductor on the degree of foaming and the thickness of the protective film of two-layer insulation. At a degree of porosity of 40 %, the dielectric constant decreases by 25 %, the tangent of the dielectric loss angle – by 33 %, the electrical capacitance of the insulated conductor – by 20 %.G.V. BezprozvannychI.A. KostiukovO.A. PushkarNational Technical University "Kharkiv Polytechnic Institute"articleindustrial networkstwisted pairinsulated conductorfoaminginsulation thicknesseffective dielectric constantelectrical capacitanceElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENRUUKElectrical engineering & Electromechanics, Iss 1, Pp 44-49 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN RU UK |
topic |
industrial networks twisted pair insulated conductor foaming insulation thickness effective dielectric constant electrical capacitance Electrical engineering. Electronics. Nuclear engineering TK1-9971 |
spellingShingle |
industrial networks twisted pair insulated conductor foaming insulation thickness effective dielectric constant electrical capacitance Electrical engineering. Electronics. Nuclear engineering TK1-9971 G.V. Bezprozvannych I.A. Kostiukov O.A. Pushkar Synthesis of constructive-technological decisions of regulation of working capacitance of cables of industrial networks |
description |
Introduction. Over the past 10 years, the number of industrial networks has more than doubled. At the physical level, all industrial technology networks are based on twisted pair. Purpose. Synthesis of constructive-technological decisions of regulation of electric capacitance of the insulated conductor at a stage of manufacturing of twisted pair of cables of industrial networks. Methodology. The method of secondary charges to determine the capacitance of the insulated conductor by varying the thickness of the solid and foamed polyethylene insulation. Practical value. Effective regulation is provided on the basis of the obtained dependencies of the effective dielectric constant, the tangent of the dielectric loss angle and the capacitance of the insulated conductor on the degree of foaming and the thickness of the protective film of two-layer insulation. At a degree of porosity of 40 %, the dielectric constant decreases by 25 %, the tangent of the dielectric loss angle – by 33 %, the electrical capacitance of the insulated conductor – by 20 %. |
format |
article |
author |
G.V. Bezprozvannych I.A. Kostiukov O.A. Pushkar |
author_facet |
G.V. Bezprozvannych I.A. Kostiukov O.A. Pushkar |
author_sort |
G.V. Bezprozvannych |
title |
Synthesis of constructive-technological decisions of regulation of working capacitance of cables of industrial networks |
title_short |
Synthesis of constructive-technological decisions of regulation of working capacitance of cables of industrial networks |
title_full |
Synthesis of constructive-technological decisions of regulation of working capacitance of cables of industrial networks |
title_fullStr |
Synthesis of constructive-technological decisions of regulation of working capacitance of cables of industrial networks |
title_full_unstemmed |
Synthesis of constructive-technological decisions of regulation of working capacitance of cables of industrial networks |
title_sort |
synthesis of constructive-technological decisions of regulation of working capacitance of cables of industrial networks |
publisher |
National Technical University "Kharkiv Polytechnic Institute" |
publishDate |
2021 |
url |
https://doaj.org/article/84c5a8424bc7442a8a8dd3583c7cf153 |
work_keys_str_mv |
AT gvbezprozvannych synthesisofconstructivetechnologicaldecisionsofregulationofworkingcapacitanceofcablesofindustrialnetworks AT iakostiukov synthesisofconstructivetechnologicaldecisionsofregulationofworkingcapacitanceofcablesofindustrialnetworks AT oapushkar synthesisofconstructivetechnologicaldecisionsofregulationofworkingcapacitanceofcablesofindustrialnetworks |
_version_ |
1718377748096876544 |