Transcatheter Balloon-Expandable Valve-in-Valve to Treat Severe Paravalvular Leak Secondary to ACURATE-neo Self-expanding Prosthesis–Annulus Mismatch

A 75-year-old male with severe symptomatic aortic stenosis underwent transcatheter aortic valve implantation with a Large (27-mm) ACURATE-neo transcatheter aortic valve, complicated by severe paravalvular leak. He developed rapid and progressive worsening heart failure. Reanalysis of the computed to...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: William Peverill, MBBS, FRCPA, Michael W.A. Chu, MD, MSc, FRCSC, Pantelis Diamantouros, MD, FRCPC, Rodrigo Bagur, MD, PhD, FRCPC, FAHA
Formato: article
Lenguaje:EN
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://doaj.org/article/855e94712eeb43ad9b5c7887ea5ef6d3
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:855e94712eeb43ad9b5c7887ea5ef6d3
record_format dspace
spelling oai:doaj.org-article:855e94712eeb43ad9b5c7887ea5ef6d32021-11-26T04:38:31ZTranscatheter Balloon-Expandable Valve-in-Valve to Treat Severe Paravalvular Leak Secondary to ACURATE-neo Self-expanding Prosthesis–Annulus Mismatch2589-790X10.1016/j.cjco.2021.06.004https://doaj.org/article/855e94712eeb43ad9b5c7887ea5ef6d32021-10-01T00:00:00Zhttp://www.sciencedirect.com/science/article/pii/S2589790X21001578https://doaj.org/toc/2589-790XA 75-year-old male with severe symptomatic aortic stenosis underwent transcatheter aortic valve implantation with a Large (27-mm) ACURATE-neo transcatheter aortic valve, complicated by severe paravalvular leak. He developed rapid and progressive worsening heart failure. Reanalysis of the computed tomography images suggested evidence of prosthesis–annulus mismatch. Therefore, a redo transcatheter aortic valve implantation utilizing a 29-mm SAPIEN 3 transcatheter aortic valve was performed. This case illustrates the importance of proper valve sizing to avoid paravalvular leak, and how to safely cross an ACURATE-neo valve to avoid catheter entangling. Résumé: Un homme de 75 ans présentant une sténose aortique symptomatique sévère a subi l'implantation d'une valve aortique par cathéter, dont une ACURATE neo de 27-mm compliquée par une fuite paravalvulaire sévère. Par la suite, le patient a présenté une insuffisance cardiaque sévère . Une nouvelle analyse de ses examens tomodensitométriques a indiqué des signes d'incompatibilité entre la prothèse et l'anneau mitral. Il a donc fallu réaliser une nouvelle implantation valvulaire aortique par cathéter avec une valve SAPIEN 3 de 29 mm. Ce cas illustre l'importance d'une bonne évaluation de l'anneau valvulaire pour éviter les fuites paravalvulaires, et décrit comment traverser une valve ACURATE neo pour éviter l'enchevêtrement du cathéter.William Peverill, MBBS, FRCPAMichael W.A. Chu, MD, MSc, FRCSCPantelis Diamantouros, MD, FRCPCRodrigo Bagur, MD, PhD, FRCPC, FAHAElsevierarticleDiseases of the circulatory (Cardiovascular) systemRC666-701ENCJC Open, Vol 3, Iss 10, Pp 1320-1322 (2021)
institution DOAJ
collection DOAJ
language EN
topic Diseases of the circulatory (Cardiovascular) system
RC666-701
spellingShingle Diseases of the circulatory (Cardiovascular) system
RC666-701
William Peverill, MBBS, FRCPA
Michael W.A. Chu, MD, MSc, FRCSC
Pantelis Diamantouros, MD, FRCPC
Rodrigo Bagur, MD, PhD, FRCPC, FAHA
Transcatheter Balloon-Expandable Valve-in-Valve to Treat Severe Paravalvular Leak Secondary to ACURATE-neo Self-expanding Prosthesis–Annulus Mismatch
description A 75-year-old male with severe symptomatic aortic stenosis underwent transcatheter aortic valve implantation with a Large (27-mm) ACURATE-neo transcatheter aortic valve, complicated by severe paravalvular leak. He developed rapid and progressive worsening heart failure. Reanalysis of the computed tomography images suggested evidence of prosthesis–annulus mismatch. Therefore, a redo transcatheter aortic valve implantation utilizing a 29-mm SAPIEN 3 transcatheter aortic valve was performed. This case illustrates the importance of proper valve sizing to avoid paravalvular leak, and how to safely cross an ACURATE-neo valve to avoid catheter entangling. Résumé: Un homme de 75 ans présentant une sténose aortique symptomatique sévère a subi l'implantation d'une valve aortique par cathéter, dont une ACURATE neo de 27-mm compliquée par une fuite paravalvulaire sévère. Par la suite, le patient a présenté une insuffisance cardiaque sévère . Une nouvelle analyse de ses examens tomodensitométriques a indiqué des signes d'incompatibilité entre la prothèse et l'anneau mitral. Il a donc fallu réaliser une nouvelle implantation valvulaire aortique par cathéter avec une valve SAPIEN 3 de 29 mm. Ce cas illustre l'importance d'une bonne évaluation de l'anneau valvulaire pour éviter les fuites paravalvulaires, et décrit comment traverser une valve ACURATE neo pour éviter l'enchevêtrement du cathéter.
format article
author William Peverill, MBBS, FRCPA
Michael W.A. Chu, MD, MSc, FRCSC
Pantelis Diamantouros, MD, FRCPC
Rodrigo Bagur, MD, PhD, FRCPC, FAHA
author_facet William Peverill, MBBS, FRCPA
Michael W.A. Chu, MD, MSc, FRCSC
Pantelis Diamantouros, MD, FRCPC
Rodrigo Bagur, MD, PhD, FRCPC, FAHA
author_sort William Peverill, MBBS, FRCPA
title Transcatheter Balloon-Expandable Valve-in-Valve to Treat Severe Paravalvular Leak Secondary to ACURATE-neo Self-expanding Prosthesis–Annulus Mismatch
title_short Transcatheter Balloon-Expandable Valve-in-Valve to Treat Severe Paravalvular Leak Secondary to ACURATE-neo Self-expanding Prosthesis–Annulus Mismatch
title_full Transcatheter Balloon-Expandable Valve-in-Valve to Treat Severe Paravalvular Leak Secondary to ACURATE-neo Self-expanding Prosthesis–Annulus Mismatch
title_fullStr Transcatheter Balloon-Expandable Valve-in-Valve to Treat Severe Paravalvular Leak Secondary to ACURATE-neo Self-expanding Prosthesis–Annulus Mismatch
title_full_unstemmed Transcatheter Balloon-Expandable Valve-in-Valve to Treat Severe Paravalvular Leak Secondary to ACURATE-neo Self-expanding Prosthesis–Annulus Mismatch
title_sort transcatheter balloon-expandable valve-in-valve to treat severe paravalvular leak secondary to acurate-neo self-expanding prosthesis–annulus mismatch
publisher Elsevier
publishDate 2021
url https://doaj.org/article/855e94712eeb43ad9b5c7887ea5ef6d3
work_keys_str_mv AT williampeverillmbbsfrcpa transcatheterballoonexpandablevalveinvalvetotreatsevereparavalvularleaksecondarytoacurateneoselfexpandingprosthesisannulusmismatch
AT michaelwachumdmscfrcsc transcatheterballoonexpandablevalveinvalvetotreatsevereparavalvularleaksecondarytoacurateneoselfexpandingprosthesisannulusmismatch
AT pantelisdiamantourosmdfrcpc transcatheterballoonexpandablevalveinvalvetotreatsevereparavalvularleaksecondarytoacurateneoselfexpandingprosthesisannulusmismatch
AT rodrigobagurmdphdfrcpcfaha transcatheterballoonexpandablevalveinvalvetotreatsevereparavalvularleaksecondarytoacurateneoselfexpandingprosthesisannulusmismatch
_version_ 1718409851827126272