Evaluation of the Impact of Static Interference on an Empirical Data Based Static Magnetic Localization Setup for Capsule Endoscopy

In this paper, the impact of interference due to the geomagnetic field on a static magnetic localization setup for capsule endoscopy, which is suitable for a wearable application, was investigated. For this purpose, a study was carried out in which the average abdomen size of 15 subjects was evaluat...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Zeising Samuel, Anzai Daisuke, Thalmayer Angelika, Fischer Georg, Kirchner Jens
Formato: article
Lenguaje:EN
Publicado: De Gruyter 2020
Materias:
R
Acceso en línea:https://doaj.org/article/85b0a61c36be4aaeb32f79cbc32a23f6
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:85b0a61c36be4aaeb32f79cbc32a23f6
record_format dspace
spelling oai:doaj.org-article:85b0a61c36be4aaeb32f79cbc32a23f62021-12-05T14:10:42ZEvaluation of the Impact of Static Interference on an Empirical Data Based Static Magnetic Localization Setup for Capsule Endoscopy2364-550410.1515/cdbme-2020-3017https://doaj.org/article/85b0a61c36be4aaeb32f79cbc32a23f62020-09-01T00:00:00Zhttps://doi.org/10.1515/cdbme-2020-3017https://doaj.org/toc/2364-5504In this paper, the impact of interference due to the geomagnetic field on a static magnetic localization setup for capsule endoscopy, which is suitable for a wearable application, was investigated. For this purpose, a study was carried out in which the average abdomen size of 15 subjects was evaluated. With the determined geometry values, a setup consisting of three elliptical sensor rings was modeled. Simulations were performed, where the magnetic flux density was evaluated at the sensors by using different-sized magnets. The measured values were compared with each other and the geomagnetic flux density. The results revealed that the measured values were for all evaluated magnet sizes of the order of the geomagnetic flux density, which is problematic since the calibration of sensors is no longer valid if the orientation of the wearable sensor array is changed. However, it is suggested that a differential measurement is suitable for the proposed system and could reduce static interference caused by the geomagnetic field.Zeising SamuelAnzai DaisukeThalmayer AngelikaFischer GeorgKirchner JensDe Gruyterarticlecapsule endoscopygeomagnetic fieldmagnetic localizationwireless capsule endoscopyMedicineRENCurrent Directions in Biomedical Engineering, Vol 6, Iss 3, Pp 66-69 (2020)
institution DOAJ
collection DOAJ
language EN
topic capsule endoscopy
geomagnetic field
magnetic localization
wireless capsule endoscopy
Medicine
R
spellingShingle capsule endoscopy
geomagnetic field
magnetic localization
wireless capsule endoscopy
Medicine
R
Zeising Samuel
Anzai Daisuke
Thalmayer Angelika
Fischer Georg
Kirchner Jens
Evaluation of the Impact of Static Interference on an Empirical Data Based Static Magnetic Localization Setup for Capsule Endoscopy
description In this paper, the impact of interference due to the geomagnetic field on a static magnetic localization setup for capsule endoscopy, which is suitable for a wearable application, was investigated. For this purpose, a study was carried out in which the average abdomen size of 15 subjects was evaluated. With the determined geometry values, a setup consisting of three elliptical sensor rings was modeled. Simulations were performed, where the magnetic flux density was evaluated at the sensors by using different-sized magnets. The measured values were compared with each other and the geomagnetic flux density. The results revealed that the measured values were for all evaluated magnet sizes of the order of the geomagnetic flux density, which is problematic since the calibration of sensors is no longer valid if the orientation of the wearable sensor array is changed. However, it is suggested that a differential measurement is suitable for the proposed system and could reduce static interference caused by the geomagnetic field.
format article
author Zeising Samuel
Anzai Daisuke
Thalmayer Angelika
Fischer Georg
Kirchner Jens
author_facet Zeising Samuel
Anzai Daisuke
Thalmayer Angelika
Fischer Georg
Kirchner Jens
author_sort Zeising Samuel
title Evaluation of the Impact of Static Interference on an Empirical Data Based Static Magnetic Localization Setup for Capsule Endoscopy
title_short Evaluation of the Impact of Static Interference on an Empirical Data Based Static Magnetic Localization Setup for Capsule Endoscopy
title_full Evaluation of the Impact of Static Interference on an Empirical Data Based Static Magnetic Localization Setup for Capsule Endoscopy
title_fullStr Evaluation of the Impact of Static Interference on an Empirical Data Based Static Magnetic Localization Setup for Capsule Endoscopy
title_full_unstemmed Evaluation of the Impact of Static Interference on an Empirical Data Based Static Magnetic Localization Setup for Capsule Endoscopy
title_sort evaluation of the impact of static interference on an empirical data based static magnetic localization setup for capsule endoscopy
publisher De Gruyter
publishDate 2020
url https://doaj.org/article/85b0a61c36be4aaeb32f79cbc32a23f6
work_keys_str_mv AT zeisingsamuel evaluationoftheimpactofstaticinterferenceonanempiricaldatabasedstaticmagneticlocalizationsetupforcapsuleendoscopy
AT anzaidaisuke evaluationoftheimpactofstaticinterferenceonanempiricaldatabasedstaticmagneticlocalizationsetupforcapsuleendoscopy
AT thalmayerangelika evaluationoftheimpactofstaticinterferenceonanempiricaldatabasedstaticmagneticlocalizationsetupforcapsuleendoscopy
AT fischergeorg evaluationoftheimpactofstaticinterferenceonanempiricaldatabasedstaticmagneticlocalizationsetupforcapsuleendoscopy
AT kirchnerjens evaluationoftheimpactofstaticinterferenceonanempiricaldatabasedstaticmagneticlocalizationsetupforcapsuleendoscopy
_version_ 1718371795384401920